Overview of Primary Product

* Vent damper may be installed hori-
zontally on all models with use of a common vent elbow.
RATINGS FOR SENTINEL BOILERS NATURAL AND L.P. GAS
* Net ratings are based on a piping and pick-up allowance of 1.15.
Slant/Fin should be consulted before selecting a boiler for installa-
tion having unusual piping and pick-up requirements. Ratings must
be reduced by 4% at 2,000 feet elevation and an additional 4% for
every additional 1,000 feet elevation over 2,000 feet.
Type of gas: after model number, specify gas by name
“Natural” or “Propane”.
Note: All Sentinel boilers are tested and rated for capacity
under the U.S. Dept. of Energy (D.O.E.) Test Procedure for boilers.
Dimensions MODELS SE-70 to SE-210
Left side view Front view Right side view
C
19
3
/
4
"
1
1
/
2
" Supply
C
(shown vertically)
Vent Damper
Pressure/Temp.
Gauge
(behind front panel)
Rollout Safety
Switch
Supply piping
(by others)
3
/
4
" Drain
3
/
4
" to air eliminating system
(by others)
Blocked vent
safety switch
(Flush Jacket)
A
B
C
(shown horizontally)
Vent Damper
Sediment Trap
(required)
(Dotted piping
by others)
Ground
Joint Union
(gas tapping
1
/
2
")
Combination
Gas Valve
1
1
/
4
" Circ. Flange
Circulator
1
1
/
2
" Return Tapping
Ignition
Control
High Limit
Control
D
28
7
/
16
"
Draft hood
28"
12"
6"
6"
6"
6"
MINIMUM CLEARANCE
DIMENSIONS
With five models ranging in size from 70,000 to 210 ,000 Btuh, Sentinel boilers meet a
wide range of residential and light commercial heating requirements. All models are avail-
able for use with natural gas or L.P. gas.
Sentinel boilers are “installer-friendly”, with features to make the contractor’s installation
and set up quicker and easier. All Slant/Fin boilers, for instance, are packaged in quick
release shipping crates to speed up unpacking. Boilers are factory-wired with quick con-
nect harnesses for the vent damper and blocked vent safety switch. Controls are all
mounted on the outside of the boiler for easy access and quick wiring. The boiler height,
including draft diverter, is up to a foot and a half lower than many natural draft boilers.
(For lower profile boilers with integral draft hoods, refer to the Slant/Fin Sentry models).
SENTINEL
MODEL
NUMBER †
CSA
INPUT
(Btuh)
DOE
CAPACITY
(Btuh)
NET
AHRI
RATING
WATER
(Btuh) *
WATER
(Sq.Ft.)
AFUE %
DIMENSIONS
A
BC
D
INTERMITTENT
IGNITION
SE-70
SE-105
SE-140
SE-175
SE-210
70,000
105,000
140,000
175,000
210,000
58,000
87,000
116,000
145,000
173,000
50,000
76,000
101,000
126,000
150,000
333
507
673
840
1000
82.0
82.1
82.2
82.2
82.3
11
1
8
"
14
1
8
"
17
1
8
"
20
1
8
"
23
1
8
"
17
5
8"
20
5
8"
23
5
8"
26
5
8"
29
5
8"
4"
5"
5"
6"
7"
45
1
2
"
46
3
16
"
46
3
16
"
47"
48
3
16
"
Motorized heavy-duty
vent damper
Relief valve
Cast-iron
heat exchanger
Pressure &
temperature
gauge
Thermal
pins
Metal
push
nipples
Insulated
base
Stainless
Steel
Burners
Heavy-duty
insulated jacket
Rollout
safety switch
(not visible)
Brand
name
controls
Circulator
Gas valve
Draft hood
HIGH PERFORMANCE, CAST-IRON GAS BOILER
DOE
SEPT. 2012
COMPLIANT
©2012 Slant/Fin Corp. Publication SE-10cv Printed in U.S.A. 912
®
BOILERS & BASEBOARD
Since 1949
T
h
e
O
n
l
y
N
a
m
e
Y
o
u
W
a
n
t
H
e
a
t
i
n
g
Y
o
u
r
H
o
m
e
U.S.A.
Slant/Fin Corporation • 100 Forest Drive
Greenvale, NY 11548 • 516-484-2600
www.slantfin.com
Canada
Slant/Fin LTD/LTEE • 6450 Northam Drive
Mississauga, Ontario L4V 1H9 • 905-677-8400
www.slantfin.ca