Brochure

CCoommppaacctt,, eeaassyy ttoo iinnssttaallll ffoorr nneeww oorr ssttaannddbbyy iinnssttaallllaattiioonnss
MMoonniittrroonn IIII ccoommbbiinneess tthhee aavvaaiillaabbiilliittyy aanndd ddeeppeennddaabbiilliittyy ooff eelleeccttrriicciittyy wwiitthh tthhee
ccoommffoorrtt aanndd ppeerrffoorrmmaannccee ooff ccoonnvveennttiioonnaall hhyyddrroonniicc hheeaattiinngg uussiinngg bbaasseebbooaarrdd,,
rraaddiiaanntt oorr ccaasstt--iirroonn rraaddiiaattoorrss..
MMoonniittrroonn IIII aass aa rreeppllaacceemmeenntt uunniitt::
Works with virtually any exist-
ing hot water hydronic radiation system. Although rated in kilowatts, it is
also clearly identified by BTU output.
MMoonniittrroonn IIII aass aa ssttaannddbbyy uunniitt::
Particularly suitable for commercial
and industrial facilities, or office buildings which can’t risk down-time
with their existing heating equipment. If oil or gas is temporarily unavail-
able, the owner easily switches the heating system to the electric boiler.
• One piece cast-iron heat exchanger
• Built in air eliminator
• Internal baffles improve heat transfer
• EM-10 electronic 4 stage boiler control
The EM-10 boiler temperature control is an efficient boiler
operator with a digital LED display with backlight, a boiler
pump output and an alarm.
Features:
Set point operation
Outdoor reset with DHW priority
External control through BMS signal
And much more
EEnneerrggyy ssaavviinngg eelleeccttrroonniicc ccoonnttrrooll
NNOORRMMAALL OOPPEERRAATTIIOONNSS
When the thermostat calls for heat, the circulator turns on and the
first electric heater bank is energized. The circulator continues oper-
ating until the room thermostat is satisfied. A flow switch supplied by
Slant/Fin or others is required. It prevents the elements from being
energized unless the circulator is operating. This avoids element
burnout.
OOPPTTIIOONNAALL MMIILLDD--WWEEAATTHHEERR OOPPEERRAATTIIOONN
Mild-weather energy savings are made possible through the use
of a warm weather shut-down feature of the control. This energy-
saving feature is standard on Monitron II models EH-8M2 through
EH-40M2.
SSttaannddaarrdd eeqquuiippmmeenntt
Up to 4 stage EM-10 electronic boiler control
Pressure and temperature gauge
Safety relief valve (unmounted)
Circulator relay and heater power relays
Circuit breaker (one or two heaters per breaker)
Drain cock,
3
4 " (packed separately)
Built-in air separator
Cast-iron ASME approved heat exchanger
Terminal strips for circulator, thermostat, flow switch,
temperature sensors and remote signal input.
• Complete jacketing
U.L. listed, ASME authorized
Flow switch. Not included with, but necessary on all models
Circuit breaker for circulator and control circuit.
MMoonniittrroonn IIII aass aa pprriimmaarryy hheeaattiinngg uunniitt ooffffeerrss::
The convenience of electricity and the comfort of hydronics.
The elimination of a chimney.
• Competitive pricing with electric baseboard systems.
• Simple zoning by zone valves.
Monitron II by Slant/Fin is the electronic-age boiler designed to
save energy for new or existing heating systems.