Instructions / Assembly

VICTORY VSPH Models
17
2. Power Connection
A. Remove electrical junction box cover.
B. Hot connection lead is black. Neutral connection lead is
white.
Proper polarity is important for VSPH boilers. Reversed
polarity will cause system lockout and the power LED will
flash continuously.
C. Connect ground wire to ground screw inside the junction box.
D. Replace junction box cover.
3. Thermostat Connections
Install thermostat on an inside wall and away from any heat
sources, sunshine and drafts. Thermostat wires must be connect-
ed to thermostat terminals block on boiler. See wiring diagram
Figure 13a.
Thermostat Heat Anticipator Adjustments:
If the 24v room thermostat that controls this boiler has an
adjustable heat anticipator, connect entire system to thermostat
and run the system while measuring the current drawn through
the thermostat wires. Set the heat anticipator at the value mea-
sured. The set current should match power requirements by zone
valves and relays. Refer to the manufacturers instruction of zone
valve and relays. Also, see instructions with the thermostat.