BTU Capacity Chart

®
RATINGS CHART – GAS BOILERS
VICTORY VSPH SERIES
©Slant/Fin Corp. 2007
SLANT/FIN CORPORA
TION, Greenvale, NY 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • In Canada:
Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com
Ratings must be reduced by 4% at 2,000 feet elevation and an additional 4% for every additional 1,000 feet elevation over 2,000 feet. Net
ratings shown include allowance from normal piping loss and pick-up load. For installations having unusual piping and pick-up requirements,
additional allowances should be made before selecting the size of boiler required. Ratings are based on a piping and pick-up factor 1.15.
Based on heat emission rate of 150 Btu per square foot.
Note: All VSPH boilers are tested and rated for capacity under the U.S. Dept. of Energy (D.O.E.) Test Procedure for Boilers
Maximum ASME working pressure: 50 psi..
MAXIMUM EQUIVALENT FLUE LENGTH
VSPH-60, 90 & 120: 40 ft.
VSPH-150: 35 ft.
VSPH-180: 33 ft.
May differ for certain vent system manufacturers and
altitudes. Vent terminal does not effect calculation
of total equivalent length.
See installation instructions, Pub. VSPH-40.
RATINGS FOR WATER
CSA D.O.E.
NET I=B=R
NET
MODEL INPUT
CAPACITY WATER WATER EFFICIENCY
No. (Btuh) (Btuh) (Btuh)† (Sq. ft)‡ (A.F.U.E.)
VSPH-60 60,000 52,000 45,000 300 86.1
VSPH-90 90,000 78,000 68,000 453 85.7
VSPH-120 120,000 103,000 90,000 600 85.5
VSPH-150 150,000 128,000 111,000 740 85.2
VSPH-180 180,000 154,000 134,000 893 85.1
Natural and L.P. Propane Gas