Installation Sheet

2. INSTALLING WATER CLOSET
NEW INSTALLATIONS
1. INSTALLING GASKET
Remove the temporary rag (if used) from the waste
pipe hole.
Lay water closet down on padded surface to help
protect the vitreous china.
Apply gasket to bowl outlet. Refer to the gasket
manufacturer’s instructions for installation.
(Note: All-wax gaskets are
NOT
recommended.)
THE RIGHT CHOICE
We thank you for your purchase.
Our products are 100% tested but should you have
any questions, please contact us by phone or at our
w
eb site.
HET* Wall Hung Water Closet Installation Instructions
RETROFIT INSTALLATIONS
1. REMOVAL OF EXISTING WATER CLOSET
Turn off the water supply.
Disconnect the flush valve.
Sponge out all remaining water from bowl.
Cut caulk all around existing bowl using utility knife
to release bowl from wall surface.
Remove the existing water closet.
Using sharp scraper or putty knife, completely
remove all remaining caulk from wall surface.
Dispose of old gasket.
2. CHECK ROUGH-IN DIMENSIONS
Check rough-in dimensions and install or relocate
flush valve and outlet as indicated.
A carrier unit is recommended to properly install
and support the wall hung water closet. Install
carrier unit (not included) per instructions provided
by the carrier manufacturer.
Verify carrier studs are level.
3. CLEAN DRAIN
Clean out waste pipe using hand or power cleaner
to be sure pipe is clear.
Proceed to NEW INSTALLATIONS.
WARNING: Hazardous gases can escape through
the closet flange if new water closet is not installed
quickly. A temporary fix: place a large rag in the
closet flange.
WARNING: Vitreous china can chip or break if the
bolts or nuts are over-tightened or if mishandled.
Check all local plumbing and building codes.
Check for any damage to the new water closet
before installation.
WHAT YOU WILL NEED…
Putty knife
Safety glasses
Measuring tape
Spud wrench
Gasket
NOTE: Plumbing System Requirements
Minimum Flowing Pressure: 25 PSI
Minimum Flow Rate: 18 GPM
Determine proper length for carrier studs per
carrier’s manufacturer.
Install (3) sets of bearing nuts and washers onto
carrier studs: two at the bottom and one on top
leaving one top stud blank.
Bearing nuts and washers must be placed to allow
a minimum gap of 1/16” between the wall and
fixture. The carrier supports the bowl, not the wall.
Place level vertically across the top and bottom
bearing nuts to ensure they are leveled.
Adjust carrier coupling to compress gasket for a
gas and watertight seal per gasket manufacturer’s
instructions.
The information contained in this document is subject to change without notice.
SLOAN VALVE COMPANY
10500 Seymour Avenue
Franklin Park, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300
Fax: 1-800-447-8329 or 1-847-671-4380
www.sloanvalve.com
Copyright © 2010 Sloan Valve Company
Code: 0816447 Rev. 2 (05/10)
5 ½"
(140mm)
Finished Floor
26 ¾” (679 mm)
14 ¼” (362 mm)
15” (381 mm) non ADA
17"-19" (432-483 mm) ADA
17 ½” (445 mm)
17 ½”
(445 mm)
7 ½"
(190 mm)
1 ½” (38 mm) Spud
9”
(229 mm)
4 ½” (114 mm) non ADA
6 ½"-8 ½” (165-216 mm)
ADA
2 3/4” (70 mm)
TO MAXIMIZE THE PERFORMANCE OF YOUR SLOAN
®
WATER CLOSET, USE ONLY SLOAN
®
FLUSHOMETERS
Sponge
10" adjustable wrench
Large level
Carrier
Gasket
Front Nut
Washer
WETS 2052.1101-1.6 ECOS
(1.6/1.1 gpf – 6.0/4.2 Lpf)
OPTIMA
®
Sensor Operated HET
Sloan ECOS
®
Flushometer and
Wall Hung Water Closet
WETS 2050.1401-1.28 G2
(1.28 gpf/4.8 Lpf)
OPTIMA
®
Sensor Operated HET
G2 Flushometer and Wall Hung
Water Closet
WETS 2050.1001-1.28
(1.28 gpf/4.8 Lpf)
Manual HET Royal
®
Manual
Flushometer and Wall Hung
Water Closet
WETS 2050.1402-1.28 SMO
(1.28 gpf/4.8 Lpf)
OPTIMA
®
Battery Powered HET
SMO Flushometer and Wall
Hung Water Closet
WETS 2050.1403-1.28
SMOOTH (1.28 gpf/4.8 Lpf)
OPTIMA
®
Sensor Operated HET
SMOOTH Flushometer and Wall
Hung Water Closet
WETS 2050.1302-1.28 HWS
(1.28 gpf/4.8 Lpf)
OPTIMA
®
AC Powered HET
SMOOTH Hard Wire Flushometer
and Wall Hung Water Closet
WETS 2050.1301-1.28 ES-S
(1.28 gpf/4.8 Lpf)
OPTIMA
®
Sensor Operated HET
Royal
®
ES-S Flushometer and
Wall Hung Water Closet
Efficiency Series
* HET does not apply to 1.6 gpf/6.0 Lpf flush volumes
Place water closet unto the carrier studs.
Loosely attach washers and front nuts on threaded
carrier studs.
Verify water closet is level.
Hand tighten the (3) nuts which have the bearing
nuts behind the water closet.
Tighten the top nut then bottom nuts alternately
while judging the flex of the bowl at the front lip
due to the compression of the gasket. Bowl is
secure and has adequate seal when no noticeable
flex occurs.
Hand-tighten the last nut and washer, then tighten
1/4-turn using a wrench.
IMPORTANT! Do not overtighten the nuts, breakage
and chipping of vitreous china can occur.
3. COMPLETING THE INSTALLATION
Flush valve should be installed to manufacturer’s
installation instructions.
Turn on water supply valve.
Install water closet seat.
Caulk around water closet.
Flush water closet a few times and check all
connections for water seepage.
Check for leaks for a few days.
Record model number for reference.
CARE AND CLEANING OF VITREOUS CHINA
Clean the water closet with a cleaner safe for vitreous
china such as Sloan’s Waterfree Urinal Cleaner/
Deodorizer. Spray and wipe clean using soft cloth. Soft
a
brasive cleaners may be used to remove stains.
LIMITED WARRANTY
Sloan Valve Company warrants its vitreous china
products to be made of first class materials, free from
defects of material or workmanship under normal use
and to perform the service for which they are intended
in a thoroughly reliable and efficient manner when
properly installed and serviced, for a period of three
years from date of purchase. During this period, Sloan
Valve Company will, at its option, repair or replace any
part or parts which prove to be thus defective if
returned to Sloan Valve Company, at customer’s cost,
and this shall be the sole remedy available under this
warranty. No claims will be allowed for labor,
transportation or other incidental costs. This warranty
extends only to persons or organizations who
purchase Sloan Valve Company’s products directly
from Sloan Valve Company for purpose of resale.
THERE ARE NO WARRANTIES WHICH EXTEND
BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN
NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE
FOR ANY CONSEQUENTIAL DAMAGES OF ANY
MEASURE WHATSOEVER.
NOTE: IN NO EVENT SHALL THE SLOAN VALVE
COMPANY BE LIABLE FOR INCIDENTAL DAMAGES,
RESULTING FROM IMPROPER INSTALLATION, OR
FOR DAMAGES CAUSED BY NEGLECT, ABUSE
OR ALTERATION.
Adjustable
Coupling
Bearing
Nuts and
Washers
Distance of washer
from wall approx.
1
/
16
2-
1
/
4
” (57 mm)
approx. from
washer face
Carrier
Studs
Finished
Wall