Specification Sheet

Repair Parts and Maintenance Guide
3.2.2
082009
G2 Optima Plus
®
Flushometer
The Sloan Valve Company introduced its Optima Plus
®
battery operated
sensor Flushometer in 1992, revolutionizing the flushing of water closets
and urinals. In both new construction and retrofit applications, the use of the
Optima Plus has become the standard method for many facilities to improve
restroom hygiene and ensure handicap accessibility compliance.
In May, 2003 Sloan introduced the G2 Optima Plus.
The G2 Optima Plus builds on the success of the original product and offers
many technological advancements to further improve on performance and
reliability expected of sensor operated plumbing. In addition to a new
aesthetic design, the G2 Optima Plus features a new state-of-the-art
electronic and optical package and a unique solenoid operator that keeps the
moving components of the solenoid completely isolated from the water
supply. This ensures long life and low maintenance regardless of local
water condition.
The G2 Optima Plus replaces the original Optima Plus product, which was
phased out of production in mid-2003.
The Sloan G2 Optima Plus automatic battery powered Flushometer relies on
an infrared sensor to detect a user and activate a flushing cycle. No physical
contact with the Flushometer surface is necessary, assuring sanitary
protection. G2 Optima Plus Flushometers are ADA compliant devices.
The Flushometer is triggered by means of an active infrared sensor. The
Optima Plus sensor emits a continuous invisible light beam. When a user
enters the beam’s effective range, the beam is reflected into the Optima
Plus scanner window. The user is now detected. After the user moves out of
the effective range of the sensor, a signal is sent to the Flushometer
solenoid and, after appropriate arming and/or flush delays, the flush cycle
is initiated.
FLEX TUBE DIAPHRAGM KIT
Regulator
Code No. Part No. Description Color *
3325003 EBV-1023-A Urinal-0.5 gpf/1.9 Lpf
†‡
GREEN
3325000 EBV-1022-A Urinal-1.0 gpf/3.8 Lpf GREEN
3325000 EBV-1022-A Urinal-1.5 gpf/5.7 Lpf
BLACK
3325001 EBV-1020-A Urinal-3.5 gpf/13.2 Lpf
WHITE
3325031 EBV-1024-A Closet-1.28 gpf/4.8 Lpf GREEN
3325001 EBV-1020-A Closet-1.6 gpf/6.0 Lpf
GREEN
3325014 EBV-1021-A Closet-2.4 gpf/9.0 Lpf BLUE
3325001 EBV-1020-A Closet-3.5 gpf/13.2 Lpf WHITE
3325001 EBV-1020-A Closet-4.5 gpf/17.0 Lpf
§
WHITE
EBV-1020-A and EBV-1022-A are supplied with multiple regulators.
A 0.5 gpf (1.9 Lpf) urinal kit can be converted to a 1.0 gpf (3.8 Lpf) by cutting and removing the
smooth A-164 flow ring from the guide.
§ For a 4.5 gpf (17 Lpf) water closet flush use EBV-1020-A with the white regulator, and cut and remove the
A-164 flow ring from the guide.
* Color of regulator to be used with flex tube diaphragm to obtain the listed flush volume.
COVER
BODY
FLUSH CONNECTION
(VACUUM BREAKER)
SPUD COUPLING
LOCKING RING
STOP COUPLING
CONTROL STOP
SUPPLY FLANGE
TAILPIECE
OUTLET COUPLING
SPUD FLANGE
OVERRIDE BUTTON
O-RING
Code No. Part No. Description
5325056 EBV-83 O-ring – 6 per package
REGULATOR
O-RING
(Code No. 5325056)
0-RING
REGULATOR
(MUST BE
INSTALLED
PAST 0-RING)
FLEX TUBE
DIAPHRAGM
FLEX TUBE
DIAPHRAGM
REGULATORS
The flush volume of the flex tube diaphragm kit is controlled by the
regulator. Regulators are identified by color. Some flex tube diaphragm kits
are supplied with multiple regulators. The installer must make sure the
proper regulator is used when installing the flex tube diaphragm kit.
REGULATOR (SOLD 6 PER PACKAGE)
Regulator
Code No. Part No. Description Color
5325122 EBV-95 Urinal-0.5 gpf/1.9 Lpf GREEN
5325122 EBV-95 Urinal-1.0 gpf/3.8 Lpf GREEN
5325129 EBV-102-2 Urinal-1.5 gpf/5.7 Lpf BLACK
5325130 EBV-102-1 Urinal-3.5 gpf/13.2 Lpf WHITE
5325122 EBV-95 Closet-1.28 gpf/4.8 Lpf GREEN
5325122 EBV-95 Closet-1.6 gpf/6.0 Lpf GREEN
5325130 EBV-102-1 Closet-3.5 gpf/13.2 Lpf WHITE
5325128 EBV-101 Closet-2.4 gpf/9.0 Lpf BLUE
EBV-1020-A and EBV-1022-A are supplied with multiple flush volume regulators.
The installer must use the correct regulator when installing the kit.