Installation Guide

1 2
Install Faucet. Slide Gasket over Flex Hose(s) and
secure with Faucet Retainer and
Nut.
A
Remove Nut, Faucet
Retainer and Gasket.
Do Not remove the
O-ring from base of
Faucet.
Install Faucet with O-ring
into the center hole in
deck or lavatory —
1-3/16" (30 mm) min. hole
required.
Note: If installing the
Faucet on a three (3) hole
sink, a Trim Plate should
be installed at this time.
FAUCET
CENTER HOLE IN
DECK OR LAVATORY
GASKET
FAUCET RETAINER
NUT
O-RING —
DO NOT REMOVE
O-RING
B
NUT
FAUCET
FLEX HOSE
O-RING
4
EAF-200 Models: Plug Transformer
into receptacle.
All Models: Remove label from
Sensor.
3
Install Strainer and Flex Hose onto
Supply Stop. Open Supply Stops.
A
Install Strainer and Flex
Hose onto Supply Stop.
B
Tighten the Flex Hose
(with Strainer in place)
securely to the Supply.
IMPORTANT: Flush dirt, debris, and sediment from Supply
Line(s) before Connecting Flex Hoses.
SUPPLY LINE/STOP
STRAINER
FLEX HOSE
TRANSFORMER
SENSOR LABEL
C
Open Supply Stop(s).
B
Remove Label from
Sensor Window.
2
A
For EAF-200 Models,
Plug Transformer into
receptacle.
Electrical Connection for up to Six (6) Faucets Using One (1) Transformer
6 VDC PLUG-IN
TRANSFORMER
DAISY CHAIN
ELECTRICAL
CABLE
DAISY CHAIN
ELECTRICAL
CABLE
DAISY CHAIN
ELECTRICAL
CABLE
TO
ADDITIONAL
FAUCETS
(6 MAX.)
CAPACITOR
CAPACITOR CAPACITOR
GASKET
FAUCET
RETAINER
MODELS POWERED BY
PLUG-IN TRANSFORMER
ONLY
DO NOT pull or crimp AC
Power Line.
NOTE: EAF-225 can only connect one (1) faucet per one (1) transformer.