Installation Sheet

Cleaning foam soap dispenser
If the tip of the soap nozzle is clogged, the
dispensing capability may fail or function partially.
Clean the nozzle according to the following
procedure:
Press the operation switch to OFF (the
operation light goes off).
Remove the nozzle using a 2.5 mm Hex key.
Next, remove the internal mesh. Wash it with
lukewarm water.
Insert the mesh and then the nozzle back
into the spout and tighten with the hex key.
Turn ON the operation switch (the operation
light goes on). Check the foam soap spraying
state.
Repeat as needed.
7
Cleaning the hand sensor
Clean the hand sensor periodically (about once a
month) according to the following procedure:
Press the operation switch to OFF (the
operation light goes off).
Gently wipe the hand sensor area with a cloth
moistened with warm water.
Press the operation switch to ON (the operation
light goes on).
Make sure that the nozzles properly dispenses
foam soap.
NOTE: Do not leave water drops on the hand
sensor area. Remaining water drops may cause a
malfunction.
Mes
h
Nozzle
Before Calling for Repair
Problem Action
Unit does not operate. Check operation switch is on.
Check power plug is securely inserted to the outlet.
Soap does not dispense. Soap bottle needs replacing.
Check soap dispensing nozzle for clog.
Clean hand sensor.
Liquid soap is not in foam state. Check mesh is mounted in the
foam-dispensing nozzle.