Installation Sheet

SF-2100/2150/2200/2250 I.I. — Rev. 0a (11/05)
Code No. 0816496
INSTALLATION INSTRUCTIONS FOR ELECTRONIC
SENSOR ACTIVATED LAVATORY FAUCETS
SF-2100 Series
Transformer Powered
with Battery Backup
Sensor Activated
Pedestal Style
Lavatory Faucets
SF-2150 Series
Battery Powered
Sensor Activated
Pedestal Style
Lavatory Faucets
LIMITED WARRANTY
Sloan Valve Company warrants its SF Series Electronic Hand Washing Faucets to be made of first class materials, free from defects of material
or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when
properly installed and serviced, for a period of one year from date of purchase. During this period, Sloan Valve Company will, at its option, repair
or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole
remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to
persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty
does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
PRIOR TO INSTALLATION
Prior to installing the Sloan SF Series Electronic
Lavatory Faucet, install the items listed below. Also,
refer to the appropriate rough-in diagram below.
PPlluugg--IInn TTrraannssffoorrmmeerr ((MMooddeellss SSFF--22110000 aanndd SSFF--
22220000 oonnllyy))
— Install electrical receptacle(s) for
plug-in transformer(s) — 120 VAC, 1 amp
service for each 6 VDC plug-in transformer used.
Hot and cold water supply lines or tempered water
supply line
Drain lines
Important:
ALL ELECTRICAL WIRING SHOULD BE INSTALLED
IN ACCORDANCE WITH NATIONAL/LOCAL CODES
AND REGULATIONS.
ALL PLUMBING SHOULD BE INSTALLED IN
ACCORDANCE WITH APPLICABLE CODES AND
REGULATIONS.
A 6 VDC STEP-DOWN TRANSFORMER MUST BE
USED FOR HARDWIRE APPLICATIONS.
BEFORE CONNECTING FLEX HOSE(S) TO SUPPLY
STOP(S), FLUSH ALL WATER LINES UNTIL WATER
IS CLEAR.
TOOLS REQUIRED FOR INSTALLATION
Electric drill for drilling anchor holes (1/4” drill
bit)
Straight blade and phillips blade screwdrivers
Open end wrenches (9, 11, 13, 16, 22 mm)
SF-2200 Series
Transformer Powered
with Battery Backup
Sensor Activated
Gooseneck Style
Lavatory Faucets
SF-2250 Series
Battery Powered
Sensor Activated
Gooseneck Style
Lavatory Faucets
FAUCET ROUGH-IN
SPOUT
TEMPERED
SUPPLY
TRIM
PLATE
GASKET
RETAINER
NUT (2)
1-1/2” (38 mm)
MAX. DECK
THICKNESS
HOT AND COLD WATER
SUPPLY APPLICATIONS
24” (610 mm)
LONG FLEX HOSE
2-1/8”
(54 mm)
3-7/8”
(98 mm)
40°
4-1/2”
(114 mm)
36” (914 mm)
LONG SENSOR
CABLE
COPPER TUBE
OR FLEX HOSE
(NOT SUPPLIED)
CONTROL MODULE
SPOUT
TEMPERED
SUPPLY
TRIM
PLATE
GASKET
RETAINER
NUT
1-1/4” (32 mm)
MIN. DIA. HOLE
REQUIRED
1-1/2” (38 mm)
MAX. DECK
THICKNESS
24”
(610 mm)
LONG FLEX
HOSE
2-1/8” (54 mm)
5-1/4”
(133 mm)
27°
10”
(254 mm)
36” (914 mm)
LONG SENSOR
CABLE
COPPER TUBE
OR FLEX HOSE
(NOT SUPPLIED)
CONTROL
MODULE
1-1/4” (32 mm)
MIN. DIA. HOLE
REQUIRED
BDM VARIATION (BELOW
DECK MECHANICAL)
MIXING VALVE
3/8” (10 mm)
BAK-CHEK TEE
HOT
SUPPLY
COLD
SUPPLY
1/2” NPSM TO
3/8” COMPRESSION
CONNECTION
1/2” NPSM TO 3/8”
COMPRESSION
CONNECTION
SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380
www.sloanvalve.com
Copyright © 2005 SLOAN VALVE COMPANY Printed 11-05
TROUBLESHOOTING GUIDE
1. Faucet delivers water in an uncontrolled manner.
A. Faucet is defective. Contact Sloan Valve Company Installation
Engineering Department (see below).
2. Faucet does not deliver any water when Sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK.”
A. Water supply stop(s) closed. Open water supply stop(s).
B. Water strainer in control module is clogged. Close supply stops and
remove water inlet line at control module. Remove, clean and reinstall
strainer and water inlet line. Replace strainer if required.
INDICATOR: Solenoid valve DOES NOT produce an audible “CLICK.”
A. Batteries low (battery powered models). Replace batteries.
B. Power failure (transformer powered models). Check power supply.
3. Faucet delivers only a slow flow or dribble when Sensor is
activated.
A. Water supply stop(s) are partially closed. Completely open water supply
stop(s).
B. Water strainer in control module is clogged. Close supply stops and
remove water inlet line at control module. Remove, clean and reinstall
strainer and water inlet line. Replace strainer if required.
C. Aerator is clogged. Remove, clean, and reinstall aerator. Replace aerator
if required.
D.Valve is defective. Contact Sloan Valve Company Installation
Engineering Department (see below).
4. Faucet does not stop delivering water or continues to drip after
user is no longer detected.
A. Valve is defective. Contact Sloan Valve Company Installation
Engineering Department (see below).
5. The water temperature is too hot or too cold on a Faucet connected
to hot and cold supply lines.
A. Supply Stops are not adjusted properly. Adjust Supply Stops.
PARTS LISTCARE AND CLEANING OF CHROME
AND SPECIAL FINISHES
DO NOT use abrasive or chemical cleaners
(including chlorine bleach) to clean Faucets that
may dull the luster and attack the chrome or
special decorative finishes. Use ONLY mild soap
and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, protect the
Faucet from any splattering of cleaner. Acids and
cleaning fluids will discolor or remove chrome
plating.
1A
1B
IItteemm PPaarrtt DDeessccrriippttiioonn
NNoo.. NNoo..
1A SFP-2-A Pedestal Faucet Assembly w/Outlet (Models SF-2100 and SF-2150)
1B SFP-3-A Gooseneck Faucet Assembly w/Outlet (Models SF-2200 and SF-
2250)
2 SFP-4 Mounting Hardware Kit, Pedestal Faucet: includes Items 2A, 2B, 2C,
2D and 2E
SFP-5 Mounting Hardware Kit, Gooseneck Faucet: includes Items 2A, 2B
and 2E
2A Rubber Gasket
2B Metal Retainer
2C Threaded Studs
2D Retainer Nuts
2E Screws and Anchors for Control Module (all models)
3 SFP-6 Plug-in Transformer (Models SF-2100 and SF-2200)
4 Batteries, 4 AA-size (all models)
5 SFP-7 Control Module, Battery Faucet (Models SF-2150 and SF-2250)
SFP-8 Control Module, Hardwire Faucet (Models SF-2100 and SF-2200)
6 SFP-9 Inlet Adapter, 1/2” NPSM to 3/8” Compression Connection (all
models)
7 SFP-10 Flex Hose, Control Module to Spout (all models)
8 SFP-11 Trim Plate with Spacer (all models)
NNoott SShhoowwnn SSeeppaarraatteellyy
SFP-12 Gooseneck Spout w/Outlet
SFP-13 Spray Head for Pedestal Faucet (Models SF-2100 and SF-2150)
SFP-14 Spray Head for Gooseneck Faucet (Models SF-2200 and SF-2250)
SFP-15 Strainer (located in water inlet of control module)
2A
2E
2D
2C
3
4
5
7
8
2B
6
SF-2100 / SF-2150 Series
SF-2200 / SF-2250 Series
When assistance is required, please contact Sloan Valve Company
Installation Engineering Department at:
1-888-SLOAN-14: (1-888-756-2614)
OR
1-847-233-2016
The information contained in this document is subject to change without notice.

Summary of content (2 pages)