1. Faucet delivers water in an uncontrolled manner.
A. Faucet is defective. Contact Sloan Valve Company Installation
Engineering Department (see below).
2. Faucet does not deliver any water when Sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK.”
A. Water supply stop(s) closed. Open water supply stop(s).
B. Water strainer in control module is clogged. Close supply stops
and remove water inlet line at control module. Remove, clean
and reinstall strainer and water inlet line. Replace strainer if
required.
INDICATOR: Solenoid valve DOES NOT produce an audible
“CLICK.”
A. Batteries low (battery powered models). Replace batteries.
B. Power failure (adapter powered models). Check power supply.
3. Faucet delivers only a slow flow or dribble when Sensor is
activated.
A. Water supply stop(s) are partially closed. Completely open water
supply stop(s).
B. Water strainer in control module is clogged. Close supply stops
and remove water inlet line at control module. Remove, clean
and reinstall strainer and water inlet line. Replace strainer if
required.
C. Aerator is clogged. Remove, clean, and reinstall aerator. Replace
aerator if required.
D. Valve is defective. Contact Sloan Valve Company Installation
Engineering Department (see below).
4. Faucet does not stop delivering water or continues to drip after
user is no longer detected.
A. Valve is defective. Contact Sloan Valve Company Installation
Engineering Department (see below).
5. The water temperature is too hot or too cold on a Faucet
connected to hot and cold supply lines.
A. Supply Stops are not adjusted properly. Adjust Supply Stops.
DO NOT USE
abrasive or chemical cleaners (including chlorine bleach)
to clean Faucets that may dull the luster and attack the chrome or
special decorative finishes. Use
ONLY
mild soap and water, then wipe
dry with clean cloth or towel.
While cleaning the bathroom tile, protect the Faucet from any
splattering of cleaner. Acids and cleaning fluids will discolor or remove
chrome plating.
When assistance is required, please contact Sloan Valve Company
Installation Engineering Department at:
1-888-SLOAN-14: (1-888-756-2614)
X
X
X
X
X
X
X
X
1
. Place hands under faucet. Solenoid valve should “click, LED in
sensor window should blink once and water should flow from the
spout.
2
. When hands are removed, the water flow should stop.
X
X
X
X
10 - TEST FAUCET OPERATION