Install Instructions

OPTIMA SYSTEMS
Electrical Box Rough-In Template for
Sensor Operated Exposed Water Closet Flushometers.
WATER CLOSET
FLUSHOMETER
TEMPLATE
TEMPLATE
ACTUAL SIZE
ELECTRICAL BOX INSTALLATION
WIRING DIAGRAM
Model: 110 ES-S/111 ES-S
(DO NOT use this template for Model 115 or 116 ES-S Flushometers)
EL-141-A YOKE ASSEMBLY (INSTALL WITH
OFFSET PORTION IN DEVICE COVER)
FINISHED WALL
OPENING
EL-201 COVER
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
2¼
(57 mm)
19”
(482 mm)
11½”
(292 mm)
2¾”
(70 mm)
1½”
(38 mm)
C/L OF
SUPPLY
1” I.P.S.
SUPPLY
(DN 25 mm)
C/L OF
ELECTRICAL
BOX
CUT ALONG DOTTED LINES
CUT ALONG DOTTED LINES
TABS OF YOKE
AND SENSOR TO BE
MOUNTED ON TOP
OF FINISHED PLASTER
OR TILE WALL
EL-1500-L SENSOR
Note: A maximum of ten (10) Sensor Flushometer units can operate
from one (1) Sloan EL-154 transformer. Class II UL Listed, 48 VA (min.)
at 24 VAC, plate mounted.
WIRING NOTES
Be certain power is OFF to prevent
damage to electrical components.
Connect sensor to transformer and
solenoid coil EXACTLY as shown in
Wiring Diagram.
Connect the 24 volt source lead to
terminal labeled “24 VAC IN” of new
sensor.
Connect solenoid lead to terminal
labeled “TO VALVE” of new sensor.
Connect remaining solenoid lead to
remaining 24 volt source lead.
Connect override button parallel to
the EL-1500-L sensor. Use 18
gauge wire between override button
terminals and the connection of the
EL-1500-L sensor.
This template will serve as a guide when
Roughing-In the Electrical Boxes required for a
Sloan OPTIMA Flushometer. If further assistance is
needed contact your nearest Sloan Representative
Office.
Refer to the OPTIMA Flushometer Installation
Instructions for directions to install and operate the
Valve.
120 VAC
24 VAC
GND
UNIT #1
UNIT #2
THRU #10
(IF USED)
IMPORTANT: Early Models of the Sensor were made with four (4)
Wire Leads. When replacing a four (4) Wire EL-150-L Sensor with
a three (3) Wire EL-150-L Sensor the Black Lead replaces the
Blue Lead, the Red Lead replaces the Yellow Lead and the White
Lead combines and replaces the Brown & Red Leads.
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • http://www.sloanvalve.com
Copyright © 2001 Sloan Valve Company Printed in the U.S.A. EL-1500-L Template — Rev. 0b (08/02) Code No. 0816157
24 VAC COIL
24 VAC COIL
SOLENOID
GROUND
WIRE
SOLENOID
GROUND
WIRE
COIL WIRE
COIL WIRE
EL-1500-L SENSOR
EL-1500-L SENSOR
EL-1500-L SENSOR
“TO VALVE”
CONNECTION
“24 VAC IN”
CONNECTION
(VIEW WITH COVER REMOVED)
NOTE: INSTALL PLASTER RING SO THAT
SCREW HOLES ARE ON THE LEFT
AND RIGHT SIDE OF BOX
HY-66 COVER
EL-152 COVER SCREWS (4) REQ’D. PER PLATE
(FLAT HEAD SOCKET SCREW #6-32 X 1/2 LG.)
4” X 4” X 2-1/2” DEEP
ELECTRICAL JUNCTION BOX
(102 mm X 102 mm X 63 mm)
4” X 4” X 2-1/2” DEEP
ELECTRICAL JUNCTION BOX
(102 mm X 102 mm X 63 mm)
WATER SUPPLY
1”
(DN 25 mm) I.P.S.
19”
(482 mm)
FROM TOP
OF FIXTURE
C/L
OF
FIXTURE
C/L
OF
FIXTURE
OVERRIDE
BUTTON
C/L
OF
ELECTRICAL
BOX
SENSOR LOCATION AND POSITIONING
IS CRITICAL!
Failure to properly position the electrical boxes to
the plumbing rough-in will result in improper
installation and impair product performance. All
tradesmen (plumbers, electricians, tile setters, etc.)
involved with the installation of this product must
coordinate their work to assure proper product
installation.
Note: When installing the valve with the EL-485-A
Positioning and Support Kit, refer to the instructions
packaged with this kit.
IMPORTANT!
DO NOT use this template for Model
115 or 116 ES-S Flushometers.
TOP OF FIXTURE
11-1/2” (292 mm)
FROM TOP
OF FIXTURE
4¾”
(121 mm)
HOW TO USE TEMPLATE
• Cut out Supply and Box openings (dotted lines).
• Place template over water supply rough-in.
• Align “C/L of Fixture” on template with actual Center Line of Fixture.
• Mount Electrical Box according to opening in template.
2-3/4” (70 mm)
CRITICAL DIMENSION
MUST BE WITHIN ± 1/8”
(3 mm)
4-3/4” (121 mm)
SLOAN ADJUSTABLE TAIL
ALLOWS ± 1/2”
(13 mm) VARIATION
POSITION OF SENSOR BOX CAN BE
RAISED OR LOWERED 1”
(25 mm) IF IN
CONFLICT WITH HANDICAP GRAB BARS
1-1/2” (38 mm)
CRITICAL DIMENSION MUST
BE WITHIN ± 1/8”
(3 mm)
FINISHED
PLASTER WALL
FINISHED
TILE WALL
4” (102 mm) SQ. X 2-1/8” (53 mm)
DEEP OUTLET BOX - APPLETON ELECT.
#4SD1 OR EQUAL (BY CONTRACTOR)
4” (102 mm) SQ. BOX DEVICE COVER
(PLASTER RING) 3/4” (19 mm) HIGH-
APPLETON ELECT. #8470 OR EQUAL
(BY CONTRACTOR)
OVERRIDE BUTTON
OVERRIDE BUTTON