User Guide

Code No. 0816434
Rev. 4 (11/11)
INSTALLATION INSTRUCTIONS FOR OPTIMA
®
SYSTEM SENSOR ACTIVATED
ROYAL
®
EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS
LIMITED WARRANTY
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3)
years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or
refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned
to Sloan Valve Company, at customer’s cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s
products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
VALVE ROUGH-IN
POSITION OF SENSOR BOX CAN BE RAISED OR LOWERED 1” (25 mm) IF IN CONFLICT WITH
HANDICAP GRAB BARS.
2-1/4”
(57 mm)
2-3/4”
(70 mm)
4-3/4”
(121 mm)
1-1/2”
(38 mm)
Y
X
1” I.P.S.
SUPPLY
(25 mm DN)
C
L
OF
ELEC.
BOX &
FIXTURE
TOP OF
FIXTURE
T.M.O.
C
L
OF
SUPPLY
X VACUUM BREAKER SIZES VARIES
ON MODEL FROM TOP OF FIXTURE
TO C/L OF SUPPLY
MODEL 110/111 - 11½” (292 mm)
MODEL 113 - 23½” (597 mm)
MODEL 115 - 24” (610 mm)
MODEL 116 - 27” (686 mm)
MODEL 110/111/113/115/116
2-1/4”
(57 mm)
2-3/4”
(70 mm)
4-3/4”
(121 mm)
1-1/2”
(38 mm)
4”
(102 mm)
11-1/2”
(292 mm)
1-1/2” (38 mm)
3/4” I.P.S.
SUPPLY
(20 mm DN)
C
L
OF
FIXTURE
C
L
OF
ELEC.
TOP OF
FIXTURE
T.M.O.
C
L
OF
SUPPLY
MODEL 186
2-1/4”
(57 mm)
2-3/4”
(70 mm)
4-3/4”
(121 mm)
1-1/2”
(38 mm)
11-1/2”
(292 mm)
1” I.P.S.
SUPPLY
(25 mm DN)
C
L
OF
FIXTURE
C
L
OF
ELEC.
TOP OF
FIXTURE
T.M.O.
C
L
OF
SUPPLY
4”
(102 mm)
1-1/2” (38 mm)
MODEL 180
MODEL 110/111
MODEL 186 MODEL 180
Exposed Closet Flushometers
1-1/2” Top Spud
• Model110/111ES-STMO
• Model113ES-STMO
• Model115ES-STMO
• Model116ES-STMO
Exposed Urinal Flushometers
3/4” Top Spud
• Model186ES-STMO
Exposed Urinal Flushometers
1-1/4” Top Spud
• Model180ES-STMO
Y SENSOR PLACEMENT VARIES
ON MODEL FROM TOP OF FIXTURE
TO BOTTOM OF SENSOR PLATE
MODEL 110/111 - 19” (483 mm)
MODEL 113 - 16” (406 mm)
MODEL 115 - 14” (365 mm)
MODEL 116 - 17” (432 mm)