Installation Guide

SLOAN FLUSHOMETER I.I. — Rev. 0 (10/05)
Code No. 0816558
INSTALLATION INSTRUCTIONS FOR EXPOSED SLOAN
WATER CLOSET AND URINAL FLUSHOMETERS
LIMITED WARRANTY
Sloan Valve Company warrants its Sloan Flushometers to be made of first class materials, free from defects of material or workmanship under
normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and
serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option,
repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the
sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only
to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
PRIOR TO INSTALLATION
Before you install the Sloan Flushometer, be sure the
items listed below are installed. Also, refer to the rough-
in diagram below.
Closet fixture
Drain line
Water supply line
Important:
ALL PLUMBING SHOULD BE INSTALLED IN
ACCORDANCE WITH APPLICABLE CODES AND
REGULATIONS.
WATER SUPPLY LINES MUST BE SIZED TO PROVIDE
AN ADEQUATE VOLUME OF WATER FOR EACH
FIXTURE.
FLUSH ALL WATER LINES PRIOR TO MAKING
CONNECTIONS.
The Sloan Flushometer is designed to operate with 10 to
100 psi (69 to 689 kPa) of water pressure. THE
MINIMUM PRESSURE REQUIRED TO THE VALVE IS
DETERMINED BY THE TYPE OF FIXTURE SELECTED.
Consult fixture manufacturer for minimum pressure
requirements. Most Low Consumption water closets (1.6
gpf/6.0 Lpf) require a minimum flowing pressure of 25
psi (172 kPa).
TOOLS REQUIRED FOR INSTALLATION
Straight blade screwdriver
Sloan A-50 Super-Wrench™, Sloan A-109 Plier
Wrench or smooth jawed spud wrench
SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380
www.sloanvalve.com
Copyright © 2005 SLOAN VALVE COMPANY Printed 10-05
Closet Flushometer
for 1½” Back Spud
MODELS 120, 121 & 122
VALVE ROUGH-IN
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean
Flushometers that may dull the luster and attack the chrome or special decorative
finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, protect the Flushometer from any splattering of
cleaner. Acids and cleaning fluids will discolor or remove chrome plating.
TROUBLESHOOTING GUIDE
1. Valve does not function (no flush).
A. Control Stop or Main Valve is Closed. Open Control Stop or Main Valve.
B. Handle Assembly is worn or damaged. Install Handle Repair Kit or replace
Handle Assembly.
C. Relief Valve is worn or damaged. Replace Inside Parts Kit.
2. Volume of water is not sufficient to siphon fixture.
A. Control Stop is not open wide enough. Adjust Control Stop for desired delivery
of water volume.
B. Urinal Flushometer Parts inside a Closet Flushometer. Replace Inside Urinal
Parts with proper Closet Flushometer Parts.
C. Low Consumption Flushometer installed on a higher Consumption fixture.
Replace Inside Parts Kit with Water Saver Kit.
D. Water Saver Kit installed in old non-Water Saver bowl. Position Refill Head so
that SIDE 1 is in the UP position.
E. Water supply volume or pressure is inadequate. If no gauges are available to
properly measure supply pressure or volume of water at the Flushometer, then
remove the Relief Valve from the Inside Parts Kit, reassemble the Flushometer
and completely open the Control Stop.
If the fixture siphons, more water volume is required. If a 3.5 gpf Inside
Parts Kit is installed in the Flushometer, then first flip the Refill Head (under
the diaphragm) to obtain a 4.5 gpf volume. If this volume is still inadequate,
remove the Flow Ring from the Guide to obtain a 6.5 gpf Kit. If additional
flow is required, try a Low Pressure Guide Kit.
IIMMPPOORRTTAANNTT LLaawwss aanndd
RReegguullaattiioonnss rreeqquuiirriinngg LLooww CCoonnssuummppttiioonn FFiixxttuurreess ((11..66 ggppff//66..00 LLppff WWaat
teerr
CClloosseettss aanndd 11..00 ggppff//33..88 LLppff UUrriinnaallss)) pprroohhiibbiitt tthhee uussee ooff hhiigghheerr fflluusshhiinngg
vvoolluummeess..
If the fixture does not siphon or if a Low Consumption fixture is installed, or
if the above steps do not prove satisfactory, steps must be taken to increase
the water supply pressure and/or volume. Contact the fixture manufacturer
for minimum water supply requirements of the fixture.
3. Flushometer closes off immediately.
A. Ruptured or damaged Diaphragm. Replace Inside Parts Kit.
B. Enlarged By-pass orifice from corrosion or damage. Replace Inside Parts Kit.
4. Length of flush is too short (short flush).
A. Diaphragm Assembly and Guide Assembly are not hand-tight. Screw the two
assemblies hand-tight.
B. Enlarged By-pass orifice from corrosion or damage. Replace Inside Parts Kit.
C. Urinal Flushometer Parts inside a Closet Flushometer. Replace Inside Urinal
Parts with proper Closet Flushometer Parts.
D. Low Consumption Flushometer installed on a higher Consumption fixture.
Replace Inside Parts Kit with Water Saver Kit.
E. Handle Assembly is damaged. Replace Handle
5. Length of flush is too long (long flush) or continuous.
A. Relief Valve is not seating properly or By-pass orifice is clogged because of
foreign material, or By-pass orifice is closed by an invisible gelatinous film
from “over-treated” water. Disassemble the working parts and wash thoroughly.
NNOOTTEE::
Size of the orifice in the by-pass is of utmost importance for the proper
metering of water into the upper chamber of the flushometer.
DDoo nnoott eennllaarrggee oorr
ddaammaaggee tthhiiss oorriiffiiccee
. Replace inside kit if cleaning does not correct problem.
B. Supply line water pressure has dropped and is not sufficient to close the valve.
Close Control Stop until pressure is restored.
C. Closet Flushometer Parts inside a Urinal Flushometer. Replace Inside Closet
Parts with proper Urinal Flushometer Parts.
D. Inside Cover is damaged. Replace Inside Cover.
6. Chattering noise is heard during flush.
A. The Segment Diaphragm is installed upside-down. Replace the Segment
Diaphragm to the proper position as instructed by markings on the Diaphragm.
A. Inside Cover is damaged. Replace Inside Cover.
7. Handle Leaks.
A. Handle Gasket, Seal or Assembly is damaged. Replace as required.
When assistance is required, please contact Sloan Valve Company Installation
Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614) OR 1-847-233-2016
PARTS LIST
1
3
2
8
Urinal Flushometer
for 1¼” Top Spud
MODEL 180
Urinal Flushometer
for ¾” Top Spud
MODEL 186
Closet Flushometer
for 1½” Top Spud
MODELS 110/111, 113,
114, 115 & 116
Service Sink
Flushometer for 1½”
Top Spud
MODEL 117
IItteemm PPaarrtt DDeessccrriippttiioonn
NNoo.. NNoo..
1 Valve Assembly
2 B-73-A ADA Compliant Handle Assembly
3 H-710-A Bak-Chek
®
Control Stop
4A V-500-AA 1-1/2" (38 mm) x 9" (229 mm) Vacuum Breaker Assembly ‡
4B V-500-AA 1-1/4" (32 mm) x 9" (229 mm) Vacuum Breaker Assembly
4C V-500-AA 3/4" (19 mm) x 9" (229 mm) Vacuum Breaker Assembly
4D V-500-A Vacuum Breaker Assembly
5 F-109 1-1/2" (38 mm) Elbow Flush Connection
6A F-56-A 1-1/2" (38 mm) Spud Coupling Assembly
6B F-57-A 1-1/4" (32 mm) Spud Coupling Assembly
6C F-58-A 3/4" (19 mm) Spud Coupling Assembly
7 F-7 Supply Flange (Supplied when Valve is not Ordered with Sweat
Solder Kit)
8 H-633-AA 1" (25 mm) Sweat Solder Kit with Cast Set Screw Flange
H-636-AA 3/4" (19 mm) Sweat Solder Kit with Cast Set Screw Flange
Part number varies with valve model variation; consult factory.
Length varies with valve model variation; consult factory.
For a complete listing of Flushometer Valve components and Repair Kits, see one
of our Maintenance Guides or consult your nearest Plumbing Wholesaler.
For optimum water conservation and Flushometer performance, use only Genuine
Sloan Parts.
NNOOTTIICCEE::
The information contained in this document is subject to change without notice.
7
6A
6A
6B
6C
4A
4D
4B 4C
5
MODEL 110/111 MODELS 113, 114,
115 & 116
MODEL 117
MODELS 120, 121, & 122 MODEL 180 MODEL 186
NOTE: Requires 1” I.P.S.
(DN 25 mm) Supply.
IIMMPPOORRTTAANNTT NNOOTTEESS::
When mounted on an ADA accessible bowl, the rough-in to the supply inlet should be no higher
than 37½” or the handle will exceed maximum height allowances under ADA guidelines.
New ADAAG Guidelines allow for Split or Offset Grab Bars, check with local authorities or
reference section 604.5.2 of ADAAG.

Summary of content (2 pages)