Installation Guide

CONTROL STOP CAP
H-700-A BAK CHEK
®
CONTROL STOP
D
Install Vandal Resistant Control
Stop Cap onto Control Stop.
4
Install Flushometer
3
Install Vacuum Breaker Flush
Connection
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
A
Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud Flange
over Vacuum Breaker Tube.
B
Insert Tube into Fixture Spud.
C
Hand tighten Spud Coupling
onto Fixture Spud.
1
Install Optional Sweat Solder Adapter
(only if your supply pipe does not have
a male thread)
A
Measure from finished wall to
C/L of Fixture Spud. Cut pipe
1¼" (32 mm) shorter than this
measurement. Chamfer O.D.
and I.D. of water supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”
(32 mm)
C/L OF
FIXTURE
SPUD
SWEAT
SOLDER
ADAPTER
B
Slide Threaded Adapter fully
onto pipe.
C
Sweat solder the Adapter to
pipe.
Thread Control Stop onto pipe.
Tighten with a wrench.
2
Install Cover Tube, Wall Flange and
Control Stop to supply pipe
BAK-CHEK
®
CONTROL STOP
COVER TUBE
IRON PIPE NIPPLE OR
COPPER PIPE WITH SWEAT
SOLDER ADAPTER
SET SCREW
SUPPLY
FLANGE
WATER
SUPPLY PIPE
SWEAT
SOLDER ADAPTER
COVER TUBE
WALL
FLANGE
SET SCREW
A
Measure from finished wall
to first thread of Adapter or
threaded supply pipe
(dimension “X”). Cut Cover
Tube to this length.
B
Slide Cover Tube over pipe.
Slide Wall Flange over Cover
Tube until against wall.
C
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
SPUD COUPLING
NYLON
SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
5
Flush Out Supply Line
A
Make sure Control Stop is CLOSED
and remove Flushometer Outer Cover.
C
Reinstall Outside and Inside Cover
wrench tight. Open Control Stop to flush
supply line. Close Control Stop and
remove Outside and Inside Cover.
B
Remove Inside Cover and lift out Inside
Parts Assembly.
D
Reinstall Inside Parts Assembly, Inside
Cover and Outside Cover wrench tight.
With the exception of Control Stop Inlet, DO NOT use pipe
sealant or plumbing grease on any valve component or coupling!
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers — DO
NOT USE toothed tools to install or service these valves. Use a
Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth
jawed spud wrench to secure all couplings. Also see “Care and
Cleaning” section of this manual.
!!! IMPORTANT !!!
This product contains mechanical and/or electrical components
that are subject to normal wear. These components should be
checked on a regular basis and replaced as needed to maintain
the valve’s performance.
!!! IMPORTANT !!!
C
Align Flushometer Body and securely tighten first the Tailpiece Coupling
(1), then the Vacuum Breaker Coupling (2), and finally the Spud
Coupling (3). Use a wrench to tighten these couplings in the order
shown.
B
Align Flushometer directly above the Vacuum Breaker Flush Connection
by sliding the Flushometer Body IN or OUT as needed. Tighten Vacuum
Breaker Coupling by hand.
A
Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece into
Control Stop. Tighten Tailpiece Coupling by hand.
Maximum adjustment of the Sloan Adjustable Tailpiece is
1/2" (13 mm) IN or OUT from the standard 4-3/4" (121 mm)
(centerline of Flushometer to centerline of Control Stop).
If roughing-in measurement exceeds 5-1/4” (133 mm),
consult factory for longer tailpiece.
NOTE
MMOODDEELLSS 111100//111111,,
111133,, 111144,, 111155,,
111166,, 111177
MMOODDEELLSS 112200,, 112211,, 112222
MMOODDEELL 118800 MMOODDEELL 118866
Tighten Set Screw with a 1/16” hex
wrench.
DDOO NNOOTT
install Vandal
Resistant Stop Cap at this time.
D
ELBOW FLUSH
CONNECTION
6
Adjust Control Stop and Install Vandal
Resistant Stop Cap
B
Activate Flushometer.
A
Open Control Stop COUNTERCLOCKWISE one FULL turn from closed
position.
C
Adjust Control Stop after each flush until the rate of flow delivered
properly cleanses the fixture.
TURN COUNTER-
CLOCKWISE TO OPEN
TURN CLOCKWISE
TO CLOSE
The Sloan Flushometer is engineered for quiet operation. Excessive water flow
creates noise, while too little water flow may not satisfy the needs of the fixture.
Proper adjustment is made when plumbing fixture is cleansed after each flush
without splashing water out from the lip AND a quiet flushing cycle is achieved.
!!! IMPORTANT !!!
TAILPIECE COUPLING
CONTROL
STOP
1
FLUSHOMETER
BODY
VACUUM
BREAKER
COUPLING
2
ADJUSTABLE TAILPIECE
O-RING
G-44
FRICTION
RING
SPUD
COUPLING
3
C/L
FIXTURE
C/L
SUPPLY
VACUUM
BREAKER
FLUSH
CONNECTION
4-3/4”
(121 mm)
±1/2”
(13 mm)
With the exception of Control Stop Inlet, DO NOT use pipe
sealant or plumbing grease on any valve component or coupling!
!!! IMPORTANT !!!
If you have questions about how to install your Sloan Flushometer,
consult your local Sloan Representative or call Sloan Installation
Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614) OR 1-847-233-2016