Spec Sheet
ROYAL® SENSOR FLUSHOMETER
ROYAL 142 ESS-1.6-OR-2-10-3/4-LDIM-HW
Sloan 10500 Seymour Ave, Franklin Park, IL 60131
Phone: 800.982.5839 • Fax: 800.447.8329 • sloan.com
Code 3911339 • Downloaded 06/29/21 • 07/28/20 • View Latest Version
Page 1 of 2
CODE NUMBER
3911339
DESCRIPTION
1.6 gpf, Rough Brass Finish, Fixture Connection Top Spud, Single
Flush, 2-10.75 L Dimension, Electrical Override, Hardwired, Sensor-
Operated, Royal® Concealed Sensor Hardwired Water Closet
Flushometer.
DETAILS
Flush Volume: 1.6 gpf (6.0 Lpf)
Finish: Rough Brass (RB)
Power Type: Hardwired (HW)
Valve: Diaphragm
Valve Body Material: Semi-red Brass
Fixture Type: Water Closet
Fixture Connection: Top Spud
Spud Coupling: 1 ½" (38mm)
Supply Pipe: 1" (25mm)
L Dimension: 2" – 10 ¾" (51 – 273mm) (2-10-3/4-LDIM)
Override: Electrical (OR)
FEATURES
PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed
Bypass
User friendly three (3) second Flush Delay
OPTIMA® EL-1500 Self-Adaptive Infrared Sensor with Indicator Light
Die Cast Sensor Plate with no visible Fasteners (for 2-gang
Electrical Box)
Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass
and No External Volume Adjustment to Ensure Water Conservation
Stop Seat and Vacuum Breaker molded from PERMEX® Rubber
Compound for Chloramine Resistance
High Back Pressure Vacuum Breaker Flush Connection and Spud
Coupling for 1 1/2” Concealed Top Spud
1” I.P.S. Wheel Handle Bak-Chek® Angle Stop
Courtesy Flush® Override Button
VIDEOS
ESS Flushometer
COMPLIANCES & CERTIFICATIONS
(UL Certified, ADA Compliant, cUPC Certified, BAA Compliant)
RECOMMENDED SPECIFICATION
Valve Body, Cover, Tailpiece and Control Stop shall be in
conformance with ASTM Alloy Classification for Semi- Red
Brass. Valve shall be in compliance with the applicable
sections of ASSE 1037 and ANSI/ASME 112.19.2.
ELECTRICAL SPECIFICATIONS
Arming Delay: 16 seconds
Control Circuit: 24 VAC Input
Flush Delay: 3s
Self-Adaptive Window: ±10
Sensor Range: 22" – 42" (559 – 1,067mm)
Solenoid Operator: 24 VAC
Transformers:
0345154
0345999
VALVE OPERATING PRESSURE (FLOWING)
15 – 80 PSI (103 – 552 kPa). Specific fixtures may require greater
minimum flowing pressure - consult manufacturer
requirements.
DOWNLOADS
Royal ESS Concealed and Exposed Installation Instructions
Control Stop Repair and Maintenance Guide
Flush Connections Flanges Repair and Maintenance Guide
Tail Piece Repair and Maintenance Guide
Optima ESS Repair and Maintenance Guide
Additional Downloads
NOTES
All information contained within this document subject to
change without notice.
Looking for other variations of the ROYAL 142 ESS product?
View the general spec sheet with all options.


