7 Commissioning
SMA Solar Technology AG
Installation ManualSBSxx-US-10-IA-xx-1258
7.3 Establishing a connection to the user interface
7.3.1 Establishing a Direct Connection via Ethernet
Requirements:
The product must be commissioned.
An end device (e.g. computer) with an Ethernet interface must be available.
The product must be connected directly to the end device.
The respective latest version of one of the following web browsers must be installed: Chrome,
Edge, Firefox, Internet Explorer or Safari.
The SMA Grid Guard code of the Installer must be available for the changing of grid-relevant
settings after completion of the first ten feed-in hours or installation assistant (see "Application
for SMAGridGuard Code" at www.SMA-Solar.com).
IP address of the inverter
Standard inverter IP address for direct connection via Ethernet: 169.254.12.3
Procedure:
1. Open the web browser of your device, enter the IP address 169.254.12.3 in the address line
and press the enter key.
2.
Web browser signals a security vulnerability
After the IP address has been confirmed by pressing the enter key, a message might
appear indicating that the connection to the user interface of the inverter is not secure.
SMA Solar Technology AG guarantees that calling up the user interface is secure.
Continue loading the user interface.
The login page of the user interface opens.
7.3.2 Establishing a direct connection via WLAN
Requirements:
The product must be commissioned.
An end device (e.g. computer, tablet PC or smartphone) must be available.
The respective latest version of one of the following web browsers must be installed: Chrome,
Edge, Firefox, Internet Explorer or Safari.
JavaScript must be enabled in the web browser of the end device.
The SMA Grid Guard code of the Installer must be available for the changing of grid-relevant
settings after completion of the first ten feed-in hours or installation assistant (see "Application
for SMAGridGuard Code" at www.SMA-Solar.com).