User and installation manual
10 Technical Data
SMA Solar Technology AG
Installation Manual SBSxx-US-10-IA-xx-12 71
10.1.2 SunnyBoyStorage 6.0-US
AC connection
SBS6.0-US-10
Rated power 6000W
Maximum apparent AC power 6000VA
Rated grid voltage 240V
AC voltage range 211V to 264V
Nominal AC current 25A
Maximum output current during stand-alone
mode
32A
Total harmonic factor of output current <4%
Maximum residual output current 198Apeak
Duration of the maximum residual output current 33ms
Line synchronization characteristics/inrush cur-
rent
Method 2/18.5A
Rated power frequency 60 Hz
Limits of accuracy of voltage measurement 2% of the AC voltage
Limits of accuracy of frequency measurement ±0.1Hz
Limits of accuracy of time measurement at nomi-
nal trip time
± 0.1 %
Limits of accuracy of current measurement 1% of the AC current
Limits of accuracy of power (active/reactive)
measurement
5% of the nominal AC power
Limits of accuracy of power factor measurement 0.01
Limits of accuracy of time measurement 0.001s
Operating range at AC power frequency 60Hz 59.3Hz to 60.5Hz
Output power at +60°C (+140°F) > 4000W
Power factor at rated power 1
Range of the displacement power factor (ad-
justable)
0.8
overexcited
to 0.8
underexcited
Feed-in phases 1
Phase connection 2
Overvoltage category in accordance with
UL1741
IV
ENGLISH