TECHNICAL DATA (PRELIMINARY*) SUNNY TRIPOWER CORE1
Input (DC)
Max. DC power (at cos φ = 1) / 
DC rated power
51000 W / 51000 W
Max. input voltage 1000 V
MPP voltage range / rated input voltage 150 V to 1000 V / 500 V to 800 V
Min. input voltage / start input voltage 150 V / 188 V
Max. operating input current / per MPPT 120 A / 20 A
Max. short circuit current per MPPT / 
per string input
30 A / 30 A
Number of independent MPPT inputs / 
strings per MPP input
6 / 2
Output (AC)
Rated power (at 230 V, 50 Hz) 50000 W
Max. apparent AC power 50000 VA
AC nominal voltage
3 / N / PE; 220 V / 380 V
3 / N / PE; 230 V / 400 V
3 / N / PE; 240 V / 415 V
AC voltage range 180 V to 280 V
AC grid frequency / range
50 Hz / 44 Hz to 55 Hz
60 Hz / 54 Hz to 65 Hz
Rated power frequency /
 rated grid voltage
50 Hz / 230 V
Max. output current / 
Rated output current
72.5 A / 72.5 A
Output phases /
 line connections
3 / 3
Power factor at rated power / 
Adjustable displacement power factor
1 / 0.0 leading … 0.0 lagging
THD 3 %
Protective devices
Input-side disconnection device
Ground fault monitoring / grid monitoring ● / ●
DC reverse polarity protection / 
AC short-circuit current capability / 
galvanically isolated
● / ● / –
All-pole sensitive
residual-current monitoring unit
Protection class
(according to IEC 62109-1) / overvoltage
category (according to IEC 62109-1)
I / AC: III; DC: II
AC/DC surge arrester (Type II)
 / 
TECHNICAL DATA (PRELIMINARY*) SUNNY TRIPOWER CORE1
Eciency
Max. eciency / European eciency >98.0 % / >98.0 %
General data
Dimensions (W / H / D)
621 mm /733 mm /569 mm
(24.4 in /28.8 in /22.4 in)
Weight 82 kg (180 lb)
Operating temperature range -25°C to +60°C (-13 °F to +140 °F)
Noise emission (typical) <60 dB(A)
Self-consumption (at night) <5 W
Topology / Cooling concept Transformerless / OptiCool
Degree of protection (as per IEC 60529) IP65
Climatic category (according to IEC 60721-3-4) 4K4H
Max. permissible value for
relative humidity (non-condensing)
100 %
Features / functions / accessories
DC connection / AC connection SUNCLIX / screw terminal
LED indicators (status / fault / communication)
Interface: Ethernet / WLAN / RS485 ● (2 ports) /● / 
Data interface: SMA Modbus / SunSpec
Modbus / Speedwire, Webconnect
● / ● / ●
Multi-Function relay / 
Expansion Module Slots
● / ● (2 ports)
OptiTrac Global Peak / Integrated Plant
Control / Q on Demand 24/7
● / ● / ●
Off-grid capable / SMA Fuel
Save Controllercompatible
● / ●
Guarantee: 5 / 10 / 15 / 20 years ● / 
 /   / 
Certicates and permits
(more available on request)
*
Does not apply to all national
appendices of EN50438
ANRE 30, AS 4777, BDEW 2008,
C10/11:2012, CE, CEI 0-16, CEI 0-21,
EN 50438:2013
*
, G59/3, IEC 60068-2-x,
IEC 61727, IEC 62109-1/2,
IEC 62116, MEA 2013, NBR 16149,
NEN EN 50438, NRS 091-2-1, PEA 2013,
PPC, RD 1699/413, RD 661/2007,
Res. n°7:2013, SI4777, TOR D4,
TR 3.2.2, UTE C15-712-1, VDE 0126-1-1,
VDE-ARN 4105, VFR 2014, P.O.12.3,
NTCO-NTCyS, GC 8.9H, PR20, DEWA
● Standard features
Optional – Not available
Data at nominal conditions – preliminary version: 11/2016
Type designation STP 50-40
Eciency Curve Assessories
SMA
SensorModule
MD.SEN-US-40
Output power / Rated power
Eciency [%]
SMA
RS485 Module
MD.RS485-US-40
AC Surge Protection Module Kit
AC _SPD_ Kit1-10
DC Surge Protection Module Kit
DC_SPD_Kit4-10
SMA
IO-Module
MD.IO-40
Antenna
Extension Kit
EXTANT-US-40
*December 2016