Installation Manual

SB 5.0-1SP-US-40 SB 6.0-1SP-US-40
Range of the displacement power factor (ad-
justable)
0.8
overexcited
to 0.8
underexcited
0.8
overexcited
to 0.8
underexcited
Feed-in phases 1 1
Phase connection 2 2
Overvoltage category in accordance with
UL1741
IV IV
AC output, secure power supply operation
Maximum AC power 2000W
Nominal AC voltage 120V
AC voltage range 109V to 132V
Maximum output current 16A
Minimum load 1 W
Multifunction relay
Maximum DC switching voltage 30V
Maximum AC switching current 1.0A
Maximum DC switching current 1.0A
Minimum load 0.1W
Minimum electrical endurance when the maxi-
mum switching voltage and maximum switching
current are complied with*
100000 switching cycles
* Corresponds to 20years at 12switching operations per day
Triggering thresholds and tripping time
Rated power fre-
quency
Triggering threshold Triggering frequency Tripping time
60 Hz >60.5 Hz 60.45Hz to 60.55Hz max. 0.1602 s
<57Hz to 59.8Hz
(Standard: 59.3Hz)
56.95Hz to 59.85Hz
(Standard: 59.25Hz
to 59.35Hz)
Adjustable: 0.16s to
300s
(Standard: max.
0.1602s)
<57.0 Hz 56.95 Hz to 57.05 Hz max. 0.1602s