Installation Manual

Typical noise emission <25dB(A)
Power loss in night mode <5W
Maximum data volume per inverter with Speed-
wire/Webconnect
550 MB/month
Additional data volume when using the Sun-
nyPortal live interface
600 kB/hour
Topology Transformerless
Cooling method Convection
Enclosure type rating in accordance with UL50 NEMA 3R
Protection class 1
Grid configurations 208V delta connection,
240V delta connection,
208V delta connection : 120V wye
connection,
240V : 120V split-phase system
Approvals and national standards, as per
08/2015
UL 1741, UL 1699B, IEEE 929-2000, IEEE
1547, Canadian Electrical Code® CSA C22.2
No. 107.1-01
Torques
Screw M5x60 for securing the inverter to the
wall mounting bracket
1.7Nm ± 0.3 Nm (15.05in-lb ± 2.65in-lb)
Screws for attaching the enclosure lid of the
Connection Unit
3Nm ± 0.3Nm (26.55in-lb ± 2.65in-lb)
Screws for grounding at equipment grounding
terminals
6Nm ± 0.3Nm (53.10in-lb ± 2.65in-lb)
Screws for AC-out connecting terminal plate for
AC connection
0.3Nm (2.65in-lb)
Screws for DC-in connecting terminal plate for
DC connection
0.3Nm (2.65in-lb)
Screws for SPS connecting terminal plate for
connecting the outlet for secure power supply
operation
0.3Nm (2.65in-lb)
Data Storage Capacity
Energy yields in the course of the day 63days
Daily yields 30 years
10 Technical Data
SMA Solar Technology America LLC
Installation manualSB5.0-6.0-1SP-US-40-IA-xx-1064