5 Mounting SMA America, LLC
20 CU600-1000US-IA-en-10 Installation Manual
Information on mounting the Connection Unit below a Sunny Tripower
• You can mount the Connection Unit directly below the Sunny Tripower. The output
openings of the Connection Unit must be exactly below the openings for the DC
connection of the Sunny Tripower.
• Align the oblong holes of the mounting straps of the Connection Unit, the oblong holes
of the wall mounting brackets of the Sunny Tripower, and the drill holes for the screw in
the rear panel of the Sunny Tripower to each other.
• In order to have the conduits at the Sunny Tripower and at the Connection Unit correctly
positioned, the left oblong hole of the wall mounting bracket of the Sunny Tripower and
the left oblong hole of the Connection Unit must be flush one below the other.
Example: