Manual

5
www.smartavi.com
Product - Installation Diagram
FDX-M2P
Receiver
2 DVI-D Displays
USB Keyboard
USB Mouse
Stereo Speakers
Fiber Optic Cable Specications
• Multimode: Two bers 50μm or 62.5μm. For example: I-V(ZN)H 2G50 (In house patch
cable)or I-V(ZN)HH 2G62,5 (In house Breakout cable) or I/AD(ZN)H 4G50 (in
house OR outdoor Breakout cable, stress resistant) or A/DQ(ZN)B2Y 4G62,5
(outdoor cable, stress resistant with protection against animal biting) All notations
acc. VDE specication.
•Singlemode: Two bers 9μm. For example: I-V (ZN)H 2E9 (In house patch cable) or IV(
ZN)HH 2E9 (In house Breakout cable) or I/AD(ZN)H 4E9 (in house OR outdoor
Breakout cable, stress resistant) or A/DQ(ZN)B2Y 4G9 (outdoor cable, stress
resistant with protection against animal biting) All notations acc. VDE specication.
A point to point connection is required. Having one or more patch panels in the
line is possible and allowed. Telecommunications or network equipment may not be
connected to the ber optic connectors, doing so may cause damage to the device.