User Manual

4
5
Normal Keypad Operation:
• If the user enters a 4-digit code that is matched to one of the 25 stored codes. The STATUS light should
blink rapidly indicating that it is sending command to operator.
• No more than 20 key presses are allowed to obtain the 4-digit entry code.
Example:
1234 is one of the codes stored in one of the memory location.
The user can enter “x1234” or “xxxxxxxxxxxxxxxx1234” and the gate should be activated (x is any key).
If more than 20 key presses is entered without matching one of the codes then the unit’s STATUS light
should be ashing rapidly and no entry will be accepted for the next 40 seconds. The user must not enter
any code for at least 40 seconds before the unit returns to normal operation; otherwise it remains in this
“lock-down” mode. Once the user enters a matched code, any subsequent key press within the next 40
seconds will cause the keypad to send command to gate opener.
Keying Indication Summary:
Keying Error Alert Indication Keying accepted confirmation Indication
Master Code Setting Speaker: continuous Beep for 2 seconds Speaker: Beep – Beep – Beep
STATUS light: rapid ashing STATUS light: 3 ashes along with beeps
Permanent Entry Code Speaker: continuous Beep for 2 seconds Speaker: Beep – Beep – Beep
STATUS light: rapid ashing STATUS light: 3 ashes along with beeps
Temporary Entry Code Speaker: continuous Beep for 2 seconds Speaker: Beep – Beep – Beep
Setting STATUS light: rapid ashing STATUS light: 3 ashes along with beeps
Entering Entry Code Speaker: continuous Beep for 2 seconds Speaker: Beep – Beep – Beep
STATUS light: 3 ashes along with beeps
STATUS light: rapid ashing 40 seconds after entering code