User manual

Technische Daten
smart DPA 21 7
The device is direct current (DC) controlled. Therefore, use only accessories with
DC-pass and decoupling diodes!
The use of conventional sockets with DC-pass without diodes can lead to the
destruction of the receiver!
3 Receivers’ Setting
Please configure your receiver for a Unicable system. Usually this is under the menu item "Installation /
Settings". Please, read also the receiver's manual.
You can use only Unicable-compatible receivers! Ask your dealer or receiver
manufacturer if the necessary software is available for your device.
3.1 Automatic Installation
If an automatic installation is available, please start this. After the successful run, following data are dis-
played: Table 1
UB
1
/ Slot / Receiver Number Frequency
1 1400 MHz
2 1516 MHz
Assign to each receiver one number with the associated frequency.
You may assign the number and frequency only once! If two receivers have the
same number, then both receivers switch the program simultaneously!
3.2 Manual Installation
If you configure the Unicable system, then assign the receiver number and the associated frequency
according to Table 1. Assign to one receiver one number with the associated frequency.
4 Technical Data
Input frequency range terrestrial
2
: 47 – 862 MHz
Through loss terrestrial: 2 dB
Input frequency range SAT-IF: 950 - 2150 MHz
Gain SAT: 5 dB
Output frequency (UB) Slot1:
1400 MHz
Output frequency (UB) Slot2:
1516 MHz
Isolation terrestrisch / SAT: >25 dB
Maximum output level terrestrial.: 83 dBμV
Maximum output level SAT: 95 dBμV
Control signal: DiSEqC für Unicable
3
Output Control signal LNB / Multi- Analog, DiSEqC 1.0
Temperature range: -10 … +40 °C
1
UB = User Band, also „UB Slot“,„UB-Frequenz“, in Unicable systems the output frequencies.
2
Pass from input1 (Slot1) to output
3
Standard: EN16769