User Manual

12
Traceability control system PC software
The field shows the tightening range that can be set on the torque wrench.
(5) [Total number]
The field shows the number of torque data sets stored in the memory of the torque
wrench.
(6) [Date]
The date and time information which the torque wrench has recorded will be displayed.
[Update]
System time icon to display the time and date information on the PC.
Date and time information by writing to the torque wrench will be updated.
(7) [Battery level indicator] The right side of the Menu bar
The battery remaining amount of the torque wrench is displayed.
3) Pattern setting
Up to 10 operation patterns (PT01 to PT10) can be set on the torque wrench.
Select a cell of a pattern and the following window will appear.
(1) [Lower torque]
Sets an arbitrary value of the lower limit torque.
(2) [Upper torque]
Sets an arbitrary value of the upper limit torque.
(3) [Control number]
Point
* Enter a positive number for a clockwise (CW) direction and a negative
number for a counterclockwise (CCW) direction.