<OC1>,<OC2>,<OC3>,<OC4>,<OC5>,<SN1>,<SN2>,<SN3>,<SN4>,<SN5>,
<T_Floor>,<Add_Noiset>}
All parameters are bytes and are offset by +32 (20 Hex).
For SAS-1 software versions SAS_131 and above, the Send Parameters command not only
sends parameters to the SAS-1, but causes the parameters to be written to non-volatile
flash memory.
SAS-1 Response:
No Response.
Command to SAS-1: Set SAS Baud Rate
<ESC>{SASxxxx,BAUD=Baud_Rate}
Baud_Rate is a byte and is offset by +32 (20 Hex).
Baud_Rate = 0 “2400 bps” This rate will not support TAI or RELAY operating modes.
1 “4800 bps” This rate will not support TAI or RELAY operating modes.
2 “9600 bps” This rate will not support support RELAY mode.
3 “19200 bps” This rate will not support RELAY mode.
4 “38400 bps”
5 “57600 bps”
6 “115200 bps”
SAS-1 Response:
Chr(2)OKChr(3) “OK” is ASCII.
Command to SAS-1: Save Parameters to SAS-1 NonVolatile Memory
<ESC>{SASxxxx,WPRM}
SAS-1 Response:
Chr(2)OKChr(3) “OK” is ASCII.
For SAS-1 Software Revision SAS_131 or higher, this command has no effect.
Command to SAS-1: Get SAS-1 ID
<ESC>{SAS0000,GETID}