User Manual

SmarTek Systems (www.smarteksys.com)
9
SAS-1 Response:
Chr(2)SASyyyyChr(3)
SASyyyy is the SAS-1 ID (ASCii)
Each connected SAS-1 responds to the above command with a 0.5 second delay corresponding
to its SAS ID. For example, SAS0001 responds after 0.5 second, SAS0002 responds after 1.0
seconds, SAS0003 responds after 1.5 seconds, and so on.
Command to SAS-1: Change SAS-1 ID
<ESC>{SASxxxx,CHGID=SASyyyy}
SASxxxx is current ID and SASyyyy is new ID.
SAS-1 Response:
Chr(2)OKChr(3) “OK” is ASCii.
Command to SAS-1: Set SAS-1 Default Operating Mode
<ESC>{SASxxxx,DMODE=<D_Mode>,<Monitor_Mode>,<InetSw>,<Comm_Mode>,
<Network_Number>,<Rpt_Intv>}
All parameters are bytes and are offset by +32 (20 Hex). See Get SAS Parameters command for
parameter definitions.
SAS-1 Response:
Chr(2)OKChr(3) “OK” is ASCii.
Command to SAS-1: Continue Output from SAS-1
<ESC>{SASxxxx,CONT}
When SAS-1 is set to TAI data mode, this command must be sent to the SAS-1 every 374 scans
(29.92 seconds) or SAS-1 output will stop and fall back (after 5 minutes) to default operation as
specified by the D_MODE parameter.