User's Manual

Page 20 of 60 2334-2xx- Rev: 12/13/2012 1:54
PM
Responders (both dimming and non-dimming) will immediately turn full-off.
Press and hold to activate
Dimming responders will begin to brighten, unless they are already at full-on.
Non-dimming responders will ignore the command and remain at their current state.
When you release the button, the responders will stop going brighter.
Once the scene is activated, pressing and holding the button will toggle between brightening and dimming the
responders. Non-dimmable responders will ignore press-and-hold brighten/dim commands and remain at their
current state.
LED Behavior
Keypad has a dual-color green and red LED which momentarily indicates whether an on or an off is being sent.
LED State Meaning
Blinks green once On command sent
Blinks red once Off command sent
Blinks red for a few
seconds
One or more scene members did not acknowledge (note: scene members
may still have heard the scene command and adjusted their settings)
Local On-Level
The local on-level is the default brightness level at which the light(s) physically wired to Keypad will turn on. The
default local on-level is 100%, but can be set to any one of 33 settings, 32 fixed brightness levels (3% to 100%) or
“Resume Bright,” which will result in the light returning to the brightness level it was at prior to being turned off.
We recommend using home-management software such as HouseLinc to set the local on-level. However, you can
also change it manually by following the steps below.
1) Press and hold Set button until it beeps.
Set button LED will blink green.
2) Press and hold Set button until it beeps again.
Set button LED will blink red.
3) Press and hold Set button until it beeps a third time.
Set button LED will blink green.
4) Press and hold Set button until it beeps a fourth time.
Set button LED will blink red.
5) Tap Set button once.
Keypad will beep and Set button LED will double-blink red.
6) Using the scene controller button, adjust load to desired brightness level.
7) When satisfied, press and hold Set button once to save local on-level settings.
Keypad will double-beep and Set button LED will stop blinking.
Air Gap
To remove all power from Keypad and connected light(s), pull out the Set button at the bottom of the switch as far
as it will go, about 1/8”. (It might be helpful to use a small screwdriver.) This will open the mechanical contacts and