User's Manual
Page 6 of 14 2475DA1 - Rev: 4/20/2012 4:35 PM
Using In-LineLinc Dimmer Dual-Band
LEDs
LED
Meaning
Solid green Load is on (at any dim level)
Solid red Load is off
Blinking green Unit is in linking mode
Blinking red Unit is in unlinking mode
Fast blinking red and optional
blink-on-traffic is turned on
Dimmer is off and INSTEON traffic received
Fast blinking green and optional
blink-on-traffic is turned on
Dimmer is on and INSTEON traffic received
Using the ON and OFF Buttons
The small button switches allows you to test the load and functions prior to final installation.
- Tap ON button to make load turn on at local ramp rate to local on-level brightness
- Tap OFF button to make load turn off at local ramp rate to full-off
- Double-tap ON button to make load turn full-on quickly
- Double-tap OFF button to make load turn full-off quickly
- Press and hold ON button to gradually brighten load to full-on
- Press and hold OFF button to gradually dim load to full-off
Button Functions
Button Tap Double-Tap Press and Hold
ON
Ramp to on-level Fast on Brighten
OFF
Ramp to off Fast off Dim
Set
Set the default
on-level
Sets the default
ramp rate
Starts linking
mode
Local On-Level
The local on-level is the brightness level at which the light(s) physically wired to In-LineLinc Dimmer Dual-
Band turn on. The default on-level is 100%, but it can be adjusted to any brightness level.
1) Use either ON or OFF buttons on In-LineLinc Dimmer Dual-Band to adjust light to desired brightness.
2) Tap the In-LineLinc Dimmer Dual-Band’s Set button.
SwitchLinc will beep.