User's Manual

Page 10 of 13 Rev: 12/7/2011 3:09 PM
1) If possible, remove all scene memberships prior to performing the factory reset (see Remove
FanLinc from a Scene above)
2) Turn circuit breaker Off
3) While Pressing & holding FanLinc’s Light Set button, have a friend turn circuit breaker back on
As you continue to press & hold, FanLinc will emit a long continuous (((((Beep)))))
4) Continue to press & hold the Light Set button for >5 seconds, release when beeping stops
As soon as you release the Light Set button, the FanLinc LED will turn on solid green and
then turn off. After a few seconds, FanLinc will (Beep)-(Beep) and the LED will turn
GREEN and the Fan light will turn on
X10 Programming
Instructions on setting X10 primary address can be found online:
http://www.smarthome.com/insteon-x10-programming.html
Specifications
General
Product Name FanLinc – INSTEON In-Line, Dual-Load Module
Brand Smarthome
Manufacturer Product Number 2475F
UPC 813922011548
FCC ID SBP2475F
Patent Number 7,345,998 US, International Patents Pending
Warranty 2 Years, Limited
INSTEON
INSTEON ID 1
Scenes 2 Responder Groups
Maximum Scene Links 400
On Off
Brighten Dim
Scene Commands Supported
Fast On Fast Off
Software Configurable Yes
RF Range > 150’ Open Air
X10 Support Yes
X10 Addresses 2 max
Beeper Yes