User's Manual
Quic
k
-Start Guide
Page 1 of 2
Rev. 09-23-2010
SMART Limited Warranty – SMART warrants to original consumer of this product for a period of 2 years from date of purchase, this product will be free from
defects in material & workmanship & will perform in substantial conformity with its Owner's Manual. Warranty shall not apply to defects caused by misuse or
neglect.
U.S. Patent No. 7,345,998, International patents pending © Copyright 2010
SMART, 16542 Millikan Ave., Irvine, CA 92606, 866-883-9220
Backlit LCD
Display
Up button
(glows red)
7 Day Thermostat
Model: 4715
Heat or Cool
Demand Indicator
Mode button
Down button
(glows blue)
Installation
1) RF-only devices require at least one dual-band INSTEON product for communication. For the best INSTEON
network performance, be sure you have properly installed at least two dual-band INSTEON products.
2) Remove the old thermostat, but keep the old thermostat for reference purposes, until 7 Day Thermostat is
functioning properly
3) Remove the front cover from 7 Day Thermostat
4) Mount 7 Day Thermostat using the included hardware
5) Configure the jumpers. (See the 7 Day Thermostat Installation and Programming Guide.)
6) Refer to the chart and diagrams below for basic 1 stage cooling, 1 stage heat wiring. For other wiring
diagrams, see the Installation and Programming Guide.
Wire from the old thermostat
terminal marked
Function
Install on the new thermostat
connector marked
G or F Fan G
Y1, Y, or C Cooling Y1
W1, W or H Heating W1/O/B
Rh, R, M, Vr, A Power R
C Common C
O/B Rev. Valve W1/O/B
W2 2
nd
Stage Heat W2
MISC1 Configurable Output #1 MISC1
MISC2 Configurable Output #2 MISC2
MISC3 Configurable Output #3 MISC3
RS+5 Remote Sensor +5vdc RS+5
RS1 Remote Sensor Signal RS1
RSGND Remote Sensor Ground RSGND
RS2 Remote Sensor Signal #2 RS2
7) Reattach the front cover to 7 Day Thermostat
Wiring Diagrams
Residential & Commercial 1 Stage Cooling, with 1
st
Stage Gas Heat Residential & Commercial 1 Stage Cooling, with 1
st
Stage Electric Heat
Controlling 7 Day Thermostat
• Tap an On or Scene button on a Linked Controller to recall the thermostat mode and set points established during Linking
• Tap an Off button on a Linked Controller to turn off the thermostat and set points established during Linking
• Tap the Bright* button on a Linked Controller to raise the set point(s) by a single degree
• Tap the Dim* button on a Linked Controller to lower the set point(s) by a single degree
*To prevent “runawa
y
” temperature set points, these operations onl
y
appl
y
to Controllers with Bright/Dim buttons.