User's Manual
Table Of Contents
- About Micro On/Off
- Before Installation
- Identifying the Electrical Wires in Your Home (North America only)
- Identifying the Electrical Wires in Your Home (Europe/Australia/New Zealand)
- Installation
- Switch Operation Mode
- 3-Way Toggle Mode (Latching Switches Only, Default)
- Local Control Operation
- Adjust Local Settings
- INSTEON Setup
- INSTEON Controllers, Responders and Links
- Configure INSTEON Settings
- Make Micro Module a Responder (Set button)
- Make Micro Module a Responder (Switch)
- Make Micro Module a Controller (Set button)
- Make Micro Module a Controller (Switch)
- Groups
- Scenes
- Make Micro Module a Controller of Multiple Responders
- Remove Micro Module as a Controller
- Remove Micro Module as a Responder
- Remove Micro Module as a Controller of Multiple Responders
- Factory Reset
- X10 Setup
- Specifications
- Troubleshooting
- Certification and Warranty
- Certification
- FCC and Industry Canada Compliance Statement
- The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15B of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in re...
- WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
- Cet appareil a été testé et s’avère conforme aux restrictions relatives aux équipements numériques de classe B, d’après l’article 15 des règlements du Conseil supérieur de l’audiovisuel américain (FCC). Ces restrictions ont été instaurées pour offrir ...
- • Éloignez l’appareil du composant qui reçoit les ondes. • Branchez l’appareil dans une prise de courant CA différente de celle du composant qui reçoit les ondes. • Au besoin, consultez votre marchand électronique ou un technicien spécialisé dans le s...
- Declaration of Conformity
- ETL/UL Warning (Safety Warning)
- Limited Warranty
- Limitations
Page 15 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM
2443-422 (869 MHz) 0x31
2443-522 (921 MHz) 0x32
X10
X10 address
1 optional (comes unassigned)
X10 transmitter
Yes
X10 receiver
Yes
X10 status response
Supported
X10 resume dim
Supported (by setting local on-level to zero)
X10 minimum transmit level
3.2 Vpp into 5 Ohms
X10 minimum receive level
20mV into 5 Ohms
X10 messages repeated
No
Mechanical
Mounting
Behind switch or outlet, or above light fixture in a single-gang electrical
box
Wires
Sense 1 (yellow wire), 0.205mm
2
/ 24 AWG
Sense 2 (purple wire), 0.205mm
2
/ 24 AWG
Max Cable Size
4mm
2
(2.72mm diameter) / 12 AWG
Min Cable Size
1.5mm
2
/ 15 AWG
Screw Micro connections
Line
Load 1
Load 1, second terminal
Neutral
Case Color
White
Set button
Yes
Plastic
UV stabilized ABS+PC
Beeper
Yes
LED
1, RGB
Dimensions
46.6mm H x 46.6mm W x 17.5mm D (1.8” H x 1.8” W x 0.7” D)
Weight
71.5g (2.5 oz)
Operating Environment
Indoors
Operating Temperature Range
32°F to 104°F (0°C to 40°C)
Operating Humidity Range
0-90% relative humidity
Storage temperature range
-4
o
to 158
o
F (-20
o
to 70
o
C)
Electrical
Voltage
100VAC to 240VAC
Frequency
50/60Hz auto detected at power-up
Maximum load
15A – 240VAC (US)
16A – 240VAC (EUR)
10A – 240VAC (AUS/NZ)