User's Manual
Table Of Contents
- About Micro On/Off
- Before Installation
- Identifying the Electrical Wires in Your Home (North America only)
- Identifying the Electrical Wires in Your Home (Europe/Australia/New Zealand)
- Installation
- Switch Operation Mode
- 3-Way Toggle Mode (Latching Switches Only, Default)
- Local Control Operation
- Adjust Local Settings
- INSTEON Setup
- INSTEON Controllers, Responders and Links
- Configure INSTEON Settings
- Make Micro Module a Responder (Set button)
- Make Micro Module a Responder (Switch)
- Make Micro Module a Controller (Set button)
- Make Micro Module a Controller (Switch)
- Groups
- Scenes
- Make Micro Module a Controller of Multiple Responders
- Remove Micro Module as a Controller
- Remove Micro Module as a Responder
- Remove Micro Module as a Controller of Multiple Responders
- Factory Reset
- X10 Setup
- Specifications
- Troubleshooting
- Certification and Warranty
- Certification
- FCC and Industry Canada Compliance Statement
- The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15B of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in re...
- WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
- Cet appareil a été testé et s’avère conforme aux restrictions relatives aux équipements numériques de classe B, d’après l’article 15 des règlements du Conseil supérieur de l’audiovisuel américain (FCC). Ces restrictions ont été instaurées pour offrir ...
- • Éloignez l’appareil du composant qui reçoit les ondes. • Branchez l’appareil dans une prise de courant CA différente de celle du composant qui reçoit les ondes. • Au besoin, consultez votre marchand électronique ou un technicien spécialisé dans le s...
- Declaration of Conformity
- ETL/UL Warning (Safety Warning)
- Limited Warranty
- Limitations
Page 8 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM
Single Momentary Switch
Dual Momentary Switch
Adjust Local Settings
Change LED Brightness (or turn it off)
Default = 50% brightness level
1) Press and hold Set button until it beeps
LED will start blinking green
2) Press and hold Set button until it beeps again
LED will start blinking red
3) Press and hold Set button until it beeps a third time
LED will start blinking green
4) Tap Set button once
LED will start double-blinking green
5) Press and hold Set button until it beeps
LED will turn green (at brightness of connected load)
6) Press and hold Micro module on/off buttons to brighten or dim LED to desired brightness
7) Tap Set button
Micro On/Off will double-beep and return to ready mode
Error Blink
Default = enabled
This setting is only adjustable via software or a central controller. Micro module LED will blink red once if one or more
responders do not acknowledge a message and will blink green once if all responders are successful.
Connected load/responders
Single momentary switch
Tap
Press and hold
Double-tap
LED
Switch
On/Off
(ramped)
Brighten/Dim
until release or full-on/off
(dimmable responders only)
On/Off
(instant)
Green/
Red
Connected load/responders
Dual momentary switch
Tap
Press and hold
Double-tap
LED
Top
On
(ramped)
Brighten
until release or 100%
(dimmable responders only)
On
(instant)
Green
Bottom
Off
(ramped)
Dim
until release or off
(dimmable responders only)
Off
(instant)
Red