8.1 Technical Parameters
DC Voltage:
Automatic range, test range:
±600V
AC Voltage:
Automatic range, test range:
±600V
DC Current:
Automatic range, test range:
±10A (external sensors are
required for large range
currents).
AC Current:
Automatic range, test range:
±10A. Average value
measurement (external
sensors are required for large
range currents).
Resistance:
Automatic range, test range:
0Ω~6MΩ
Diode:
0~2.0V
On-off detection:
Sound when it is lower than
30Ω
8.2 How to Operate
The P03 host is equipped with a multimeter function button area.
In addition to operating through the screen touch button, you can
also set and control the multimeter function module through the
buttons in the function button area.
Button Position
Button
Identification
Button Description