Product Manual
CONTROLS (see fig. 1)
ON/OFF - If left idle for 6 minutes, SMARTTOOL™
will automatically shut off.
HOLD - Push to “freeze” and “unfreeze” display
readings.
DIRECTIONAL LISTEN & LEVEL AUDIO -
Push to activate and de-activate the beeper.
Directional Beep rate increases as 0˚, 90˚, or the
copied angle is approached and changes tone
when the angle is passed.
CALIBRATE (see Calibration Procedures)
° % mm/M - Push to change the display units:
Degrees (°), Slope (%), Pitch (mm/M).
MM/M
Pitch readings are in 1mm increments.
Note: The ° % mm/M button can be used
even when the display is in HOLD. This feature is a
convenient way to convert angles from one unit to
another. For example a 417 mm/M roof pitch
measurement can be converted to 22.6° for setting
up cuts on a chop saw.
LCD DISPLAY
Display reads right side up when SMARTTOOL™ is
upside down!
UP/ DOWN ARROWS - Left and right indicators
point toward level or plumb (whichever is closer).
Indicators get shorter as SMARTTOOL™ gets closer to
level (0˚) or plumb (90˚) or copied angle.
LOW BATTERY - Low 9V battery indicator.
Replace battery within 24 hours.
DIGITAL DISPLAY Display readout of current
measurement.
TM
CALIBRATION PROCEDURES
To read accurately, SMARTTOOL™ must be calibrated
through all eight calibration steps. If the
CALIBRATE button is pushed when SMARTTOOL™
is not near level or plumb, the display will show
" --- " and SMARTTOOL™
will ignore the calibration
attempt. If CAL ALL appears on the display,
SMARTTOOL™
needs to be calibrated through all
eight calibration steps.
Note: We recommend checking calibration daily,
after a rough fall, or if the temperature has
changed by more than 20 F since the previous
calibration. To check calibration, follow the above
procedures without depressing the CALIBRATE
button. If the readings vary by more than 0.1 deg.
then SMARTTOOL™ should be recalibrated.
Step 1: Place SMARTTOOL™
on a flat surface with
the display facing you. Turn it on and wait 10
seconds. Push and hold the CALIBRATE button for
2 seconds until CAL1 appears on the display.
Step 2: Rotate SMARTTOOL™ end-for-end on the
flat surface with the display now facing away
from you. Wait 10 seconds. (see fig. 3)
Push and hold the CALIBRATE button for 2
seconds until CAL2 appears on the display.
Step 3: Place SMARTTOOL™ upside down facing
DIRECTIONAL LISTEN & LEVEL AUDIO -
° % mm/M MODES - Indicates measurement
"mode": Degrees (˚), Slope (%), Pitch (mm/M).
ALTERNATE ZERO-
ALTERNATE ZERO
Alt zero allows you to set any angle as a 0˚
reference point from which to take measure-
ments. Set the new 0˚ by pressing "Hold" then
"Cal/Alt 0. The display shows "Alt" then "-0-"
then the new 0˚. A dot flashes above the decimal
point while in "Alt O" mode. Discontinue"Alt
)" mode by pressing "Hold/Copy" or "Cal/Alt
0". Beep, ˚, % and mm/M continue function
as normal.
ANGLE COPY
To copy angles, place unit on angle to be copied.
Press the Hold/Copy button. Push the
Listen and Level Audio button. Level will
begin beeping. The "copy" angle will remain
frozen on the display. A beep will sound when
the unit is returned to this exact angle.
To remove the unit from the angle copy mode,
push the Hold/Copy button or the Listen
and Level Audio button. This operation will
return the unit to the regular mode.
BATTERY INSTALLATION
The battery is inside the endcap opposite the
plumb vial. To install the battery, remove the
endcap using a coin or blade in the slot provided.
Be careful not to pull on the battery wires.
Note: SMARTTOOL™ includes a 9-volt battery,
however, it is not connected. Before checking
your SMARTTOOL™, connect the battery. Use only
9-volt alkaline batteries.
you. Wait 10 seconds. Push and hold the
CALIBRATE button for 2 seconds until CAL1
appears on the display.
Step 4: Rotate SMARTTOOL™, still upside down,
end-for-end on the flat surface with the display
now facing away from you. Wait 10 seconds. Push
and hold the CALIBRATE button for 2 seconds until
CAL2 appears on the display. (see fig. 4)
Step 5: Place SMARTTOOL™ against a flat vertical
surface with the display facing you, the plumb
vial at the bottom, and the level vial away from
the surface. Wait 10 seconds. Push the
CALIBRATE button for 2 seconds until CAL1
appears on the display.
Step 6: Turn SMARTTOOL™ with the display facing
away from you, along its long axis (the plumb vial
is still at the bottom, but the level vial is now
against the flat vertical surface.) Wait 10 seconds.
Push the CALIBRATE button for 2 seconds until
CAL2 appears on the display. (see fig. 5)
Step 7: Place SMARTTOOL™ against the flat vertical
surface with the plumb vial at the top and the
display facing you. Wait 10 seconds. Push the
CALIBRATE button for 2 seconds until CAL1
appears on the display.
Step 8: Turn SMARTTOOL™ along its long axis, with
the plumb vial still at the top but the display now
facing away from you. Wait 10 seconds. Push the
CALIBRATE button for 2 seconds until CAL2
appears on the display.
MAINTENANCE
The following tips will ensure that your SMARTTOOL™
is kept in top condition.
• The SMARTTOOL™ is weather and water resistant.
Should SMARTTOOL™ be splashed with mortar or
other construction site residue, simply wipe
clean with a damp cloth. Do not immerse the
SMARTTOOL™ in water.
• Aluminum surfaces can be cleaned with a
non-abrasive cleansing powder.
• ABS polymer surfaces should be cleaned with
a mild liquid soap and water.
• We advise you to store SMARTTOOL™ away from
extreme temperatures below 20°F (-4°C) or
higher than 140°F (60°C).
ONE YEAR LIMITED WARRANTY
If within one year from the date of original
purchase, the SMARTTOOL™ fails to function because
of defects in materials or workmanship, M-D will,
at its option, either repair or replace such
components provided the original purchaser:
1. Call 1-405-528-4411 for a Return
Authorization Number.
2. Returns the SMARTTOOL™ postage paid and
insured to M-D at the address set forth below.
M-D is not responsible for any damage incurred
to the components while in transit to M-D;
3. Includes a brief explanation describing why
the SMARTTOOL™ is inoperable, or how the
component was damaged;
4. Sends the materials to:
M-D Building Products, Inc.
Service Center Authorization
4411 N. Santa Fe
Oklahoma City, OK 73118
This warranty does not cover damage resulting
from accident, misuse or abuse, water, tampering,
servicing performed or attempted by unauthorized
agencies, or units that have been modified in any
fashion. If the components do not perform as
warranted herein, the original purchaser's sole
remedy will be the repair or replacement of the
components as provided above. In no event will
M-D be liable for damages, lost revenue, lost
wages, lost savings or any other incidental or
consequential damages, domestic or international,
rising from the purchase and use or inability to use
the components, even if M-D has been advised of
the possibility of such damages. Except as provided
herein, M-D makes no warranties, express or
4
effectuée s'approche davantage du niveau ou de
l'aplomb). Les flèches raccourcissent au fur et à
mesure que le SMARTTOOL™ se rapproche du niveau
(0˚) ou de l’aplomb (90˚) ou l'angle copié.
PILES FAIBLES Indicateur de faiblesse
de la pile de 9 V. Remplacez la pile dans les 24 h.
AFFICHAGE NUMÉRIQUE Affiche les mesures
courantes.
ÉCOUTE ET NIVEAU SONORE DIRECTIONNEL
, %, mm/M Indique l'unité de mesure. Degré
(˚), pente (%) et inclinaison (mm/M).
ALTERNANCE ZÉRO
ALTERNANCE ZÉRO
Alt zéro vous permet de dénir n'importe quel
angle comme un point de référence 0 º à partir
duquel prendre les mesures. Réglez le nouveau
0 º en appuyant sur «Hold » et ensuite « Cal/Alt
0 ». L'écran ache « Alt » ensuite « -0- » et par
la suite le nouveau 0 o. Un point clignotera au-
dessus du point décimal lorsqu'en mode « Alt 0
». Discontinuez le mode « Alt 0 » en appuyant
sur « Hold/Copy» ou « Cal/Alt 0 ». Beep, º, %, et
mm/M continu à fonctionner normalement.
COPIE D'ANGLE
Pour copier des angles, placez l'appareil sur
l'angle à copier. Appuyez sur le bouton de Hold
(Retenue). Puis sur le bouton Son et Niveau
du Son. Le niveau commencera à émettre un
signal sonore. L'angle copié demeurera affiché. Le
niveau émettra un signal sonore indiquant que
l'angle désiré a été obtenu.
Pour désactiver le mode de copie d'angle, appuyez sur
le bouton Hold (Retenue) ou Son et Niveau
du Son. Le mode normal du niveau sera rétabli.
INSTALLATION DE LA PILE
(Voir la fig. 2.)
La pile est à l’intérieur de l'extrémité à l’opposé de
la fiole d’aplomb. Pour installer la pile, retirez
l'extrémité en insérant une pièce de monnaie ou
une lame dans la fente. Prenez garde de ne pas
tirer sur les fils.
REMARQUE : SMARTTOOL™ comprend une pile de 9
volts, mais cette dernière n’est pas branchée. Avant
de vérifier l’appareil SMARTTOOL™, branchez la pile.
N’utilisez que des piles alcalines de 9 volts.
INSTRUCTIONS POUR LE CALIBRAGE
PARAMÈTRE DE NIVEAU: (8 étapes)
implied, including without limitation, the implied
warranties of merchantability and fitness for a
particular purpose, with respect to the components.
All warranties for the components, express or
implied, are limited to the warranty period set forth
above. Some states do not allow limitations on how
long an implied warranty lasts or the exclusion or
limitation of incidental or consequential damages,
so the above limitations or exclusions may not apply
to you. This warranty gives you specific legal rights.
You may also have other rights, as indicated above,
which vary from state to state.
LES COMMANDES (Voir la fig. 1.)
ON/OFF MARCHE/ARRÊT Le SMARTTOOL
™
s’arrête automatiquement s’il est inutilisé pendant
6 minutes.
HOLD RETENUE Appuyez sur ce bouton pour
obtenir un affichage figé ou non figé.
ÉCOUTE ET NIVEAU SONORE DIRECTIONNEL
Appuyez sur ce bouton pour activer ou désactiver
le signal sonore. La cadence du bip (beep)
directionnel augmente lorsque le 0 º, 90 º ou
l'angle copié est pratiquement atteint et change de
tonalité lorsque l'angle est dépassé.
CALIBRATE CALIBRAGE (Voir Instructions
pour le calibrage)
, %, mm/M Appuyez sur ce bouton pour
changer les unités affichées. Degrés (˚), pente (%),
inclinaison (mm/M).
Les mesures de l’inclinaison sont indiquées par
tranches de 1 mm/M.
REMARQUE: Le bouton % mm/M peut être
utilisé même lorsque l’affichage est en mode HOLD
(RETENUE). Cette caractéristique permet de
convertir aisément les angles d’une unité à une
autre. Par exemple, la mesure d’inclinaison d’un toit
de 417mm/M peut être convertie en degrés (22.6˚)
pour établir un angle de coupe.
AFFICHAGE À CRISTAUX LIQUIDES
La lecture à l'écran se fait en partant de la droite en
montant lorsque le SMARTTOOL™ est à l’envers!
FLÈCHES VERS LE HAUT/VERS LE BAS -
Les flèches de gauche et de droite sont orientés à
la verticale ou à l'horizontale (selon que la mesure
FIG. 1
Pour fonctionner correctement, le SMARTTOOL™ doit
être calibré en effectuant les huit étapes ci-dessous.
Si vous appuyez sur le bouton Calibrate (calibrage)
alors que les paramètres de niveau et d’aplomb ne
sont pas atteints, l’appareil ne sera pas calibré et
l’écran affichera "---". Si le message CAL All
s’affiche, le SMARTTOOL™ doit être calibré en
effectuant les huit étapes de calibrage.
Remarque : Il est recommandé de vérifier le
calibrage du SMARTTOOL™ tous les jours, si vous
l’échappez ou si la température a subi des variations
supérieures à 11˚ C depuis le dernier calibrage. Si la
mesure affichée varie de plus de 0,1 degré, le
SMARTTOOL™ doit être calibré de nouveau.
Étape1: Placez le SMARTTOOL™ sur une surface
plane, l’écran face à vous. Mettez-le en marche et
attendez 10secondes. Appuyez sur le bouton
Calibrate (calibrage) et maintenez-le enfoncé
pendant 2secondes, jusqu’à ce que le message
CAL1 s’affiche.
Étape2: Faites pivoter le SMARTTOOL™ de 180
degrés. L’écran est maintenant dirigé de l’autre
côté. Attendez 10secondes (voir la fig. 3).
Appuyez sur le bouton Calibrate (calibrage) et
maintenez-le enfoncé pendant 2secondes,
jusqu’à ce que le message CAL2 s’affiche.
Étape3: Placez le SMARTTOOL™ à l’envers, l’écran
face à vous. Attendez 10 secondes. Appuyez sur le
bouton Calibrate (calibrage) et maintenez-le
enfoncé pendant 2secondes, jusqu’à ce que le
message CAL1 s’affiche.
Étape4: Faites pivoter le SMARTTOOL™ de
180degrés, toujours à l’envers. L’écran est
maintenant dirigé de l’autre côté. Attendez 10
secondes. Appuyez sur le bouton Calibrate
(calibrage) et maintenez-le enfoncé pendant
2secondes, jusqu’à ce que le message CAL2
s’affiche (voir la fig.4).
Étape5 : Placez le SMARTTOOL™ contre une surface
plane verticale, l’écran face à vous, la fiole
d’aplomb vers le bas et celle de niveau éloignée
de la surface. Attendez 10 secondes. Appuyez sur
le bouton Calibrate (calibrage) et maintenez-le
enfoncé pendant 2secondes, jusqu’à ce que le
message CAL1 s’affiche.
FIG. 2
TM
FIG. 4
FIG. 5
FIG. 3
Instructions
1
2
3
4
5
6
5
7
8
9
10
1
2
3
4
5
8
5
7
9
10
1
3 4 5 2
6 678
9
1011
11
MM/M
11
6