Manual

EN Carbon monoxide detector / Manual
DE Kohlenmonoxid Melder / Gebrauchsanweisung
FR Détecteur de monoxyde de carbone / Mode d’emploi
DECLARATION OF CONFORMITY- For DoC go to:
www.smartwares.eu/doc and follow the instructions.
FGA-138
Conform with EN50291-1:2018
Image 1:
Parts description
Koolmonoxide detector / GebruiksaanwijzingNL
Image 2:
Wall mount
Image 3:
Battery replacement
ENInstruction manual
GENERAL INFORMATION
Please read this manual carefully and retain it for future
reference.
Thank you for purchasing this Smartwares Wi-fi carbon monoxide alarm!
Please read these instructions carefully before using the carbon monoxide
alarm. Retain this information in a safe and easily accessible place for
future use and maintenance. If you have any questions or if you are
looking for additional information about your carbon monoxide alarm or
prevention of carbon monoxide poisoning, please visit our website
www.smartwares.eu.
Make/model number: FGA-138
Description: Battery powered Wi-Fi carbon monoxide alarm with an
electrochemical sensor. This apparatus contains 2 x AA Alkaline
batteries and is supplied with a wall plug and screw.
Function: Carbon monoxide alarm device intended to alert persons in
case of carbon monoxide to give them time to react properly to the
danger.
Scope of application: Carbon monoxide alarm for buildings with
residential function. The alarm is capable of delivering push notifications
to the user in case of an alarm.
IMPORTANT:
Caution: The alarm is designed in order to detect carbon monoxide; it
cannot prevent a leakage!
Caution: The carbon monoxide alarm may not be painted or covered
because this may cause loss of functionality.
Warning: The carbon monoxide alarm must be replaced no later than
10 years after production date.
When the detector has been working for ten years, the end of life indicator
will be signalled and the product cannot be used anymore. Mark the
replacement date in your calendar or register for free at
www.smartreminder.eu
WHAT IS CARBON MONOXIDE
Carbon Monoxide (CO) is an insidious poison that is released when fuels
are burnt. It is a colorless, odorless, tasteless gas and therefore very
difficult to detect with the human senses. CO kills hundreds of people
each year and injures many more. It binds to the haemoglobin in the blood
and reduces the amount of oxygen being circulated in the body. In high
concentrations, CO can kill in minutes. CO is produced by the incomplete
combustion of fuels such as wood, charcoal, coal, heating oil, paraffin,
petrol, natural gas, propane, butane etc. Examples of CO sources:
Running engine in garage Gas appliances
Oil and Gas furnaces Portable generators
Wood stoves Gas or kerosene heaters
Barbecues Clogged chimneys
Wood and gas fireplaces Heating boiler
SYMPTOMS OF CO POISONING
The following symptoms may be related to CO poisoning (ppm = parts per
million/ 1:1000.000):
50 ppm The maximum allowable concentration for continuous
exposure for healthy adults in any 8-hour period.
200 ppm Slight headaches, fatigue, nausea after 2-3 hours.
400 ppm Frontal headaches within 1-2 hours, life threatening after 3
hours.
800 ppm Dizziness, nausea and convulsions within 45 minutes.
Unconsciousness within 2 hours. Death within 3 hours.
1600 ppm Headache, dizziness and nausea within 20 minutes. Death
within 1 hour.
6400 ppm Headache, dizziness and nausea within 1-2 minutes.
Warning: The apparatus may not prevent the chronic effects of CO
exposure or protect individuals who are at specific risk, always pay
attention to the symptoms of carbon monoxide poisoning.
LOCATING THE CO ALARM
When deciding where to place your alarm, if Wi-Fi networking will be
used, please ensure that the alarm is placed within the range of the router
so that it will hold a stable 2.4Ghz Wi-Fi connection.
The Carbon Monoxide alarm is designed to detect the toxic CO fumes that
result from incomplete combustion, such as those emitted from
appliances, furnaces, fireplace and auto exhaust. If your dwelling is on a
single story, for minimum protection you should fit an alarm in the
bedrooms or in the hallway of sleeping areas. Place it as near to the
sleeping areas as possible and ensure the alarm is audible when the
bedrooms are occupied. If your dwelling is multi-story, for minimum
protection place at least one alarm on each floor.
NOTE: For maximum protection an alarm should be fitted in or near every
room that contains a fuel-burning appliance such as any gas fires, central
heating boilers, room heaters, water heaters, cookers, grills, etc.
CAUTION: This alarm will only indicate the presence of carbon monoxide
gas at the sensor. Carbon monoxide gas may be present in other areas.
Warning: A carbon monoxide alarm does not function as a replacement
for a smoke or gas detector.
POSITIONING THE CO ALARM
Carbon monoxide (CO) has a similar density to warm air and, to ensure
that the most effective use is made of the detector, it should be fitted as
follows: In rooms with a fuel-burning appliance CO will mix with the warm
air and rise up. Place the CO alarm on a the wall, 30-80 cm below the
ceiling but above the top of any doors or windows at a horizontal distance
of minimum 150cm from the possible source of CO. It is also optional to
place the alarm on a ceiling.
In rooms where people sleep or are present for a longer period of time
(bedroom, living room) place the CO alarm at breathing height. For more
information and examples see www.smartwares.eu.
Areas to be avoided include the following:
Situations where the temperature may fall below 0°C or rise above 45°C
Any area where high levels of dusty, dirty or greasy emissions could
contaminate or clog the sensor.
Behind drapes or furniture.
In the path of air discharged from a furnace / air conditioning vent or
ceiling fan.
Outside the building.
Directly above a sink or cooker.
In areas where there are a lot of lamp back and dust which will block up
the sensor.
In too damp areas.
CAUTION: This Wi-Fi carbon monoxide alarm is designed for indoor use
only. Do not expose to rain or moisture. It will not protect against the risk
of carbon monoxide poisoning when the battery has drained. Do not open
or tamper with the alarm as this could cause malfunction and risk of
electric shock.
PARTS DESCRIPTION
1. TEST/ HUSH/ NETWORK button
2. LED Indicator
3. Buzzer
4. Air inlet
MOUNTING THE CO ALARM
Before mounting your CO alarm, you have to attach the rating label in
your own language to the detector.
If networking will be used, we recommend first connecting your device
with the Connected at Home App before mounting it to the wall. See the
instructions in the segment “Wi-Fi Networking”, follow these steps to
connect your device then proceed to mounting the alarm.
In order to ensure the product is correctly installed and used, it should be
installed strictly according to this user manual or be installed by qualified
professional personnel. This CO alarm is powered by a battery and
requires no additional wiring. Make sure the alarm can be heard from all
sleeping areas or place several alarms and ensure that they are placed
within the range of your Wi-Fi router.
Wall mount installation:
Having established the mounting location ensure that there is no
electrical wiring or pipe work in the area adjacent to the mounting
surface.
Remove the mounting bracket from the device by first observing the
locking clip at the back of the mounting plate and the “lock and unlock”
turning directions at the front of the device.
Push down the locking clip at the back of the mounting plate, then turn
the alarm towards the unlocked position.
Remove the mounting plate and observe the upwards pointing arrow on
the inside of the mounting bracket.
To the left and right of the arrow there are 2 mounting holes, remove the
plastic guards from these holes and mark the mounting holes location on
the wall.
Drill 2 ø 5 mm and 40 mm depth holes in the marked position and insert
the wall plug.
Place the mounting bracket over the holes and fix it in place using the
screws provided. Do not overtighten the screws.
Remove the plastic sealing from the batteries if they are sealed, and
insert them into the battery compartment. Make sure that you fit the
batteries in accordance with the polarity markings (+ or -) within the
battery compartment.
When the batteries are correctly installed a confirmation beep will be
sounded after 5 seconds.
Attach the alarm onto the mounting bracket by aligning the fixing clips on
the alarm with the fixing grooves on the bracket then turn the alarm
towards the locked position.
After powering up the alarm it will take100 seconds for it to warm up,
during this time the LED Indicator will flash GREEN, RED and YELLOW
and the buzzer will emit 1 beep.
After the warming up period the alarm will enter Stand -by condition and
the LED indicator will flash GREEN every 30 seconds. This indicates
normal working condition.
OPERATING YOUR CO ALARM
Alarm Conditions
Alarm Condition Operation LED Buzzer
Power- up and
warm-up
Batteries are
correctly installed
and the device is
warming up.
The LED flashes
RED, GREEN and
YELLOW
alternately for
approx. 100 secs.
then stops when
the warming up is
finished.
1 short
beep
Stand-by After the warming
up period, the alarm
goes into stand-by.
The LED indicator
flashes GREEN
once every 30
seconds.
None
Test Press and release
the TEST/ HUSH/
NETWORKING
button to check
whether the CO
alarm works
properly.
The LED indicator
flashes RED 4
times.
Beeps 4
times
Alarm The presence of
Carbon Monoxide.
The LED indicator
flashes RED.
Beeps
quickly
Low battery None The LED indicator
flashes YELLOW
once every 30
secs.
1 beep
every 30
secs
Malfunction None The LED indicator
flashes YELLOW
twice every 30
secs.
2 beeps
every 30
secs.
End of Life None The LED indicator
flashes YELLOW
twice every 30
secs.
1 long beep
and 1 short
beep every
30 secs.
Exceed CO
measuring range
None The LED indicator
flashes RED
quickly.
Beeps
quickly
Hush Silence an
unwanted alarm,
push and release
the TEST/ HUSH/
NETWORK button,
it will enter HUSH
mode.
The LED indicator
flashes RED.
None
(HUSH
condition
duration:
about 10
mins)
When the CO alarm
is alarming as low
battery, push the
TEST/ HUSH/
NETWORK button,
it will enter the
HUSH mode.
The LED indicator
flashes YELLOW
once every 30
secs.
None
(HUSH
condition
duration:
about 10
mins)
Normal Operation
When no carbon monoxide is present, the green “Power” indicator LED
flashes every 30 seconds and is an indication that your alarm is powered
and functional.
Operation Malfunction
When there is a malfunction, the LED indicator flashes yellow twice every
30 seconds if there is a fault in the sensor or circuit, until the fault is
eliminated. The CO alarm will not detect CO during the malfunction and
you are not protected. Contact Smartwares for assistance.
Alarm Sounding Condition
When the unit detects dangerous levels of CO, the alarm warning will be
made. The LED indicator will flash RED and the buzzer will beep quickly
and continuously. The alarm will not stop until CO concentration is lower
than 40 ppm.
See the chapter on “What to do in case of an alarm”.
Alarm Silence
To activate silence mode, the CO concentration must be less than 200
ppm.
Alarms sounded for ppm’s higher that 200 cannot be silenced. The alarm
will be silenced when the ppm levels are no longer dangerous.
Attention!
When the CO Alarm is sounding an alarm after a suspected false alarm,
you can press the TEST/HUSH/NETWORK button and the alarm will be
silenced for 10 minutes. The alarm indicator will still flash.
While the alarm is silent it will continue to monitor the air for CO. The
alarm will sound again, if CO level in the air is still at a dangerous level.
When the alarm silence condition ends it will recover alarm condition. The
HUSH feature is to temporarily silence the alarm horn, it will not correct
the CO problem.
Press the TEST/HUSH/NETWORK button in alarm silence condition, and
it will recover alarm condition immediately.
CARBON MONOXIDE CONCENTRATION AND RESPONSE TIME
CO Concentration No alarm within Alarm at the latest
after
30 ppm 120 minutes -
50 ppm 60 minutes 90 minutes
100 ppm 10 minutes 40 minutes
300 ppm - 3 minutes
The alarm response time of this detector complies with EN 50291-1:2018.
Returning to normal operation after an alarm
Remove the alarm the mounting bracket and put in clean air, the alarm
will terminate automatically in 6 minutes, or you can quit the alarm
condition by pressing the TEST button for 1 to 3 seconds and then
release it.
Low Battery Signal / End of life warning
When the battery is low the alarm will beep once every 30 seconds and
the LED indicator will flash yellow every 30 seconds. The battery in the
apparatus needs to be replaced as soon as possible.
When your CO alarm needs replacing, the unit will beep 2 times and
yellow “Fault” LED indicator will flash 2 times. The apparatus must be
replaced with a new CO alarm as soon as possible.
Low CO concentration warning
Prolonged exposure to low levels of CO can impair the health of
vulnerable groups such as children, pregnant women, elderly or patients.
When CO concentration is greater than 30 ppm for a duration of over 120
minutes, or when CO concentration is greater than 50 ppm for a duration
of over 60 minutes, low CO concentration warning is given once every 3-5
minutes. The alarm indicator flashes 4 times with beeps at a lower speed.
TESTING YOUR CO ALARM
It is recommended that you test your CO alarm once a month to ensure
the alarm is working correctly by pressing and holding the TEST/ HUSH/
NETWORK button. If the detector is working properly, the alarm will sound
4 beep tones and the red LED will flash at the same time. If there is
malfunction, then the Malfunction warning will be given. See the “Alarm
Condition” chart in this manual for more information.
WI-FI NETWORKING
Using Wi-Fi Networking, alarm messages will be pushed to the user APP
in real time.
Installing the Connect at Home APP
Download the Connected at Home app from the Appstore or Google
Playstore.
Note: Only 2,4 GHz Wi-Fi network is supported.
Make sure you are connected to a stable 2,4GHz Wi-fi network and turn
on the Bluetooth on your mobile device. The APP should be allowed
access to Wi-fi and Bluetooth permission.
Adding the device to the Connected at Home APP
Open the APP and register or log in with existing account.
Press “Add a device” or “+”.
Press the TEST/HUSH/NETWORK button on the alarm 3 times in quick
succession, to enter pairing mode. While the alarm is in pairing mode,
the LED indicator will flash green rapidly.
Press “ADD” then enter your Wi-fi network and password.
The device- “Wi-Fi Smart Co alarm” will be added and self-test will
appear on the screen.
Press “Check”.
Your device display will show the status of your CO alarm.
You will be notified in the event of an alarm. You can modify the
notifications for the alarms in the APP settings.
Wireless Connection Test
After the alarm is added to the 2.4GHz Network, press the TEST/ HUSH/
NETWORK button to test the wireless connection. When an alarm
condition is activated, an alarm message will be transmitted to the user
APP immediately. Press “Check” in the app to silence the notification. If
there is no alarm condition the alarm will report remaining battery power to
the user APP periodically.
WHAT TO DO IN THE EVENT OF AN ALARM
In the event the CO alarm raises an alarm:
Immediately move to fresh air outdoor or open all doors/windows to
ventilate the area and allow the carbon monoxide to disperse. Where
possible turn off fuel burning appliance. Evacuate the building and do not
re-enter the premises nor move away from the open door/window until
emergency services responders have arrived, the premises have been
aired out, and your alarm remains in its normal condition. Seek medical
help immediately for anyone suffering from the symptoms of headache,
drowsiness, nausea, etc. Do not use the appliances again until they have
been checked by a qualified technician and the fault located and cleared.
If you are not in the building with the CO alarm when it sounds, DO NOT
enter the building until the source of the carbon monoxide has been
determined and the problem has been solved.
This product is not designed for use in a recreational vehicle or mobile
home. The alarm should be installed by a competent person. This
apparatus is designed to protect individuals from the acute effects of
carbon monoxide exposure. It will not fully safeguard individuals with
specific medical conditions. If in doubt consult a medical practitioner.
The installation of this CO alarm should not be used as a substitute for
proper installation, use and maintenance of fuel burning appliances
including appropriate ventilation and exhaust systems.
DO not press the TEST/HUSH/NETWORK button, this cannot cancel
the alarm. The alarm will be silenced when the CO levels has
returned to normal.
MAINTAINING YOUR CO ALARM
Your alarm will alert you to potentially hazardous CO concentrations in
your home when maintained properly. To maintain your alarm in proper
working order, it is recommended that you:
Test your alarm at least once a month.
Clean your CO alarm regularly to prevent dust build up. This can be
done using a vacuum cleaner with the brush attachment once per
month. Clean gently around the front grilled section and sides.
Never use cleaning solutions on your alarm. Simply wipe with a damp
cloth.
Do not paint the alarm.
Do not block or cover the alarm’s venthole with paste adhesive or other
things.
ATTENTION:
When scouring or stripping a wooden floor, painting, wallpapering or using
adhesive or aerosol, you should remove the carbon monoxide detector
and keep it in a safe place to prevent damaging the sensor. High
concentrations of the following substances can damage the sensor, which
often results in a false alarm: methane, propane, isopropyl butane,
ethylene, ethanol, alcohol, isopropyl alcohol, benzene, toluene, ethyl
acetate, hydrogen, hydrogen sulfate and sulfur dioxide. Also aerosol
sprays, alcoholic products, paint, solvents, adhesive, hair spray,
aftershave, perfume and certain cleaning agents can cause damage.
TECHNICAL FEATURES AND SPECIFICATIONS
Power Source 2 x AA Alkaline 1.5 V batteries
Sensor Type Electrochemical sensor
Type of Gas sensed Carbon Monoxide
Sensor Lifetime 10 Years
Operation Temperature -10°C~40°C
Ambient Humidity 0%~95% RH non-condensing
Horn Level >85 Decibels at 3 meters
Alarm output Visual and audible indication
Warm-up period Approx.100 seconds
Wi-Fi network 2.4 GHz
For indoor use only.
For DoC go to: www.smartwares.eu/doc and follow instructions.
DEInstruction manual
ALLGEMEINES
Bitte lesen Sie diese Anleitung sorgfältig durch und bewahren
Sie sie zum späteren Nachschlagen auf.
Vielen Dank, dass Sie sich für den Erwerb dieses Smartwares WLAN-
Kohlenmonoxidmelder entschieden haben! Bitte lesen Sie diese Anleitung
aufmerksam durch, bevor Sie den Melder benutzen. Bewahren Sie diese
Informationen an einem sicheren und leicht zugänglichen Ort für die
künftige Verwendung und Wartung auf. Falls Sie Fragen haben oder
zusätzliche Informationen über Ihren Kohlenmonoxidmelder oder die
Vorbeugung von Kohlenmonoxidvergiftungen wünschen, besuchen Sie
bitte unsere Website www.smartwares.eu.
Typ/Modell-Nr.: FGA-138
Beschreibung: Batteriebetriebener WLAN-Kohlenmonoxidmelder mit
einem elektrochemischen Sensor. Dieses Gerät enthält 2 Stück AA-
Alkali-Batterien und wird mit einem Wandstecker und einer Schraube
geliefert.
Funktionsweise: Der CO-Melder soll Personen beim Auftreten von
Kohlenmonoxid alarmieren und ausreichend Zeit geben, um
angemessen auf die Gefahr zu reagieren.
Anwendungsbereich: Kohlenmonoxidmelder für Gebäude mit
Wohnfunktion. Der Melder ist in der Lage, im Falle eines Alarms Push-
Benachrichtigungen an den Benutzer zu senden.
WICHTIG:
Vorsicht: Der Melder ist dafür vorgesehen, Kohlenmonoxid
festzustellen, und kann keine Undichtigkeiten verhindern!
Vorsicht: Der CO-Melder darf keinesfalls mit Farbe angestrichen oder
auf irgendeine Art bedeckt werden, um die einwandfreie Funktion zu
gewährleisten.
Warnung: Der CO-Melder muss spätestens 10Jahre nach seinem
Produktionsdatum ersetzt werden.
Nach zehn Jahren Betriebsdauer des Detektors wird das Ende der
Nutzungsdauer angezeigt und das Produkt kann nicht mehr verwendet
werden. Notieren Sie sich das Austauschdatum in Ihrem Kalender oder
registrieren Sie sich kostenlos unter www.smartreminder.eu
WAS IST KOHLENMONOXYD?
Kohlenmonoxid (CO) ist ein heimtückisches Gift, das beim Verbrennen
von Brennstoffen freigesetzt wird. Es ist ein farbloses, geruchloses und
geschmackloses Gas und daher sehr schwer mit den menschlichen
Sinnen zu erkennen. Kohlenmonoxid tötet jedes Jahr Hunderte von
Menschen und verletzt viele weitere. Es bindet sich an das Hämoglobin
im Blut und verringert die Menge des im Körper zirkulierenden
Sauerstoffs. In hohen Konzentrationen kann Kohlenmonoxid innerhalb
von Minuten töten. Kohlenmonoxid entsteht bei der unvollständigen
Verbrennung von Brennstoffen wie Holz, Holzkohle, Kohle, Heizöl,
Paraffin, Benzin, Erdgas, Propan, Butan usw. Beispiele für
Kohlenmonoxidquellen:
Laufender Motor in einer Garage Gasgeräte
Öl- und Gasheizungen Mobile Generatoren
Kaminöfen Gas- oder Kerosin-Heizgeräte
Grillgeräte Verstopfte Kamine
Holz- und Gaskamine Heizkessel
SYMPTOME EINER CO-VERGIFTUNG
Die folgenden Symptome lassen auf eine mögliche CO-Vergiftung
schließen (ppm = parts per million/ 1:1000.000):
50 ppm Die maximal zulässige Konzentration bei Dauerexposition
für gesunde Erwachsene in einem Zeitraum von 8 Stunden.
200 ppm Leichte Kopfschmerzen, Müdigkeit, Übelkeit nach 2-3
Stunden.
400 ppm Frontale Kopfschmerzen innerhalb von 1-2 Stunden, nach 3
Stunden lebensbedrohlich.
800 ppm Schwindel, Übelkeit und Krämpfe innerhalb von 45 Minuten.
Bewusstlosigkeit innerhalb von 2 Stunden. Tod innerhalb
von 3 Stunden.
1600 ppm Kopfschmerzen, Schwindelgefühl und Übelkeit innerhalb
von 20 Minuten. Tod innerhalb von 1 Stunde.
6400 ppm Kopfschmerzen, Schwindelgefühl und Übelkeit innerhalb
von 1-2 Minuten.
Warnhinweis: Das Gerät kann die chronischen Auswirkungen der
Kohlenmonoxidexposition nicht verhindern oder Personen schützen, die
einem besonderen Risiko ausgesetzt sind. Achten Sie stets auf die
Symptome einer Kohlenmonoxidvergiftung.
PLATZIERUNG DES CO-MELDERS
Bei der Entscheidung, wo Sie Ihren Melder aufstellen möchten, achten
Sie bitte darauf, dass er sich innerhalb der Reichweite des Routers
befindet, damit er eine stabile 2,4 GHz-WLAN-Verbindung
aufrechterhalten kann, wenn Sie ein WLAN-Netzwerk nutzen möchten.
Der CO-Melder ist dafür vorgesehen, giftige CO-Dämpfe zu erkennen, die
durch eine unvollständige Verbrennung entstehen (z.B. durch Geräte,
Öfen, Kamine und Autoabgase). Falls Ihre Wohnung nur eine Etage hat,
sollten Sie zum minimalen Schutz einen Melder in den Schlafzimmern
oder im Flur von Schlafbereichen platzieren. Bringen Sie ihn möglichst
nahe an den Schlafbereichen an und sorgen Sie dafür, dass der Melder
zu hören ist, wenn die Schlafzimmer belegt sind. Bei mehreren Etagen ist
zum minimalen Schutz mindestens ein Melder pro Etage vorzusehen.
HINWEIS: Für einen maximalen Schutz sollte ein Melder in jedem Raum
oder in dessen Nähe platziert werden, in dem sich eine Feuerstätte
befindet (z.B. Gasheizungen, Zentralheizkessel, Raumheizgeräte,
Wasserboiler, Herde, Grillgeräte usw.).
VORSICHT: Das Gerät schlägt bei erhöhten CO-Konzentrationen im
unmittelbaren Sensorbereich an. Beachten Sie, dass auch in anderen
Bereichen eine erhöhte CO-Konzentration vorliegen kann.
Warnhinweis: Ein Kohlenmonoxidmelder ist kein Ersatz für einen Rauch-
oder Gasmelder.
POSITIONIERUNG DES KOHLENMONOXIDMELDERS
Kohlenmonoxid (CO) hat eine ähnliche Dichte wie warme Luft. Damit der
Melder möglichst effizient funktioniert, sollte er wie folgt angebracht
werden: In Räumen mit einer Feuerstätte vermischt sich CO mit der
warmen Luft und steigt auf. Bringen Sie den CO-Melder an der Wand
(30-80cm unterhalb der Decke), aber oberhalb von Türen oder Fenstern
in einem horizontalen Abstand von mindestens 150cm von der
potenziellen CO-Quelle an. Der Melder kann auch an der Decke
angebracht werden.
In Räumen, in denen Menschen schlafen oder sich längere Zeit aufhalten
(Schlafzimmer, Wohnzimmer), bringen Sie den CO-Melder in Atemhöhe
an. Für weitergehende Hinweise und Beispiele siehe www.smartwares.eu.
Folgende Bereiche sind u.a. zu meiden:
Fälle, in denen die Temperatur unter 0°C fallen oder auf mehr als 45°C
steigen kann
Bereiche, in denen aufgrund hoher Staub-, Schmutz- oder
Sprühnebelbelastung mit starker Verschmutzung und einem Ausfall des
Sensors zu rechnen ist.
Hinter Vorhängen oder Möbelstücken.
Im Bereich von Warmluftströmen aus Öfen, Klimaanlagen oder Lüftern.
Im Außenbereich.
Direkt oberhalb von Spülbecken oder Küchenherden.
In Bereichen, in denen es viel Rückstände und Staub gibt, die den
Sensor zusetzen.
Zu feuchte Bereiche
ACHTUNG: Dieser WLAN-Kohlenmonoxidmelder ist ausschließlich für die
Verwendung im Innenbereich vorgesehen. Das Gerät nicht Regen oder
Feuchtigkeit aussetzen. Wenn die Batterie leer ist, schützt es nicht vor der
Gefahr einer Kohlenmonoxidvergiftung. Öffnen oder manipulieren Sie den
Melder nicht, da dies eine Fehlfunktion und die Gefahr eines
Stromschlags zur Folge haben kann.
BESCHREIBUNG DER KOMPONENTEN
1. Taste TEST/STUMM/NETZWERK
2. LED-Anzeige
3. Buzzer
4. Lufteinlass
MONTAGE DES KOHLENMONOXIDMELDERS
Bevor Sie den CO-Melder installieren, müssen Sie das Typenschild in
Ihrer jeweiligen Landessprache am Melder anbringen.
Wenn Sie ein Netzwerk verwenden möchten, empfehlen wir Ihnen, Ihr
Gerät zunächst mit der Connected at Home-App zu verbinden, ehe Sie es
an der Wand befestigen. Siehe die Anweisungen im Abschnitt "WLAN-
Netzwerke". Folgen Sie diesen Schritten, um Ihr Gerät zu verbinden, und
montieren Sie dann den Melder.
Um eine korrekte Installation und Verwendung des Produkts zu
gewährleisten, muss es genau nach dieser Anleitung oder von
qualifiziertem Fachpersonal installiert werden. Dieser
Kohlenmonoxidmelder wird mit einer Batterie betrieben und benötigt keine
zusätzliche Verdrahtung. Stellen Sie sicher, dass der Melder von allen
Schlafbereichen aus zu hören ist, oder bringen Sie mehrere Melder an
und stellen Sie sicher, dass sie sich in der Reichweite Ihres WLAN-
Routers befinden.
Wandmontage:
Achten Sie bei der Installation insbesondere auf elektrische
Unterputzleitungen oder Rohre im Bereich der Montagebohrungen.
Entfernen Sie die Montagehalterung vom Gerät, indem Sie zunächst den
Verriegelungsclip auf der Rückseite der Montageplatte und die "Ver- und
Entriegelungs"-Drehrichtung an der Vorderseite des Geräts beachten.
Drücken Sie den Verriegelungsclip an der Rückseite der Montageplatte
nach unten und drehen Sie dann den Melder in die entriegelte Position.
Entfernen Sie die Montageplatte und beachten Sie den nach oben
zeigenden Pfeil auf der Innenseite der Halterung.
Auf der linken und rechten Seite des Pfeils befinden sich 2
Befestigungslöcher. Nehmen Sie die Kunststoffabdeckungen von diesen
Löchern ab und markieren Sie die Position der Befestigungslöcher an
der Wand.
Bohren Sie an der markierten Stelle 2 Löcher mit einem Durchmesser
von 5 mm und einer Tiefe von 40 mm und setzen Sie den Dübel ein.
Setzen Sie die Montagehalterung auf die Löcher und befestigen Sie sie
mit den mitgelieferten Schrauben. Ziehen Sie die Schrauben nicht zu
fest an.
Entfernen Sie die Kunststoffversiegelung von den Batterien, wenn diese
versiegelt sind, und legen Sie sie in das Batteriefach ein. Achten Sie
darauf, die Batterien entsprechend der Polaritätsmarkierung (+ oder -)
im Batteriefach einzulegen.
Wenn die Batterien richtig eingelegt sind, ertönt nach 5 Sekunden ein
Bestätigungston.
Bringen Sie den Melder an der Montagehalterung an, indem Sie die
Befestigungsclips am Melder mit den Befestigungsrillen an der
Halterung ausrichten und dann den Melder in die verriegelte Position
drehen.
Nach dem Einschalten des Melders dauert es 100 Sekunden, bis er
aufgewärmt ist. Während dieser Zeit blinkt die LED-Anzeige GRÜN, ROT
und GELB und der Buzzer gibt 1 Signalton ab.
Nach der Aufwärmzeit geht der Alarm in den Bereitschaftszustand über
und die LED-Anzeige blinkt alle 30 Sekunden GRÜN. Dies zeigt einen
normalen Betriebszustand an.
BETRIEB IHRES KOHLENMONOXIDMELDERS
Alarmbedingungen
Alarmbedingung Betrieb LED Buzzer
Einschalten und
Aufwärmen
Die Batterien sind
richtig eingelegt und
das Gerät wärmt
sich auf.
Die LED blinkt für
ca. 100 Sek.
abwechselnd ROT,
GRÜN und GELB.
und stoppt dann,
wenn der
Aufwärmvorgang
beendet ist.
1 kurzer
Signalton
Bereitschaft Nach der
Aufwärmzeit geht
der Melder in den
Bereitschaftsmodus.
Die LED-Anzeige
blinkt alle 30
Sekunden einmal
GRÜN.
Kein
Test Drücken Sie die
Taste TEST/
STUMM/
NETZWERK und
lassen Sie sie
wieder los, um zu
prüfen, ob der
Kohlenmonoxidmeld
er einwandfrei
funktioniert.
Die LED-Anzeige
blinkt 4 Mal ROT.
4
Signaltöne
Alarm Das Vorhandensein
von Kohlenmonoxid.
Die LED-Anzeige
blinkt ROT.
Schnelles
Piepsen
Niedriger
Batteriestand
Kein Die LED-Anzeige
blinkt alle 30 Sek.
einmal GELB.
1 Signalton
alle 30 Sek.
Fehlfunktion Kein Die LED-Anzeige
blinkt alle 30 Sek.
zweimal GELB.
2
Signaltöne
alle 30 Sek.
Ende der
Nutzungsdauer
Kein Die LED-Anzeige
blinkt alle 30 Sek.
zweimal GELB.
1 langer
Signalton
und 1
kurzer
Signalton
alle 30 Sek.
Überschreitung
des
Kohlenmonoxidm
essbereichs
Kein Die LED-Anzeige
blinkt schnell ROT.
Schnelles
Piepsen

Summary of content (3 pages)