User's Manual
7
Technical Details
• Model: UX-2042
• Dimensions:105 × 35 mm (length × diameter)
• Weight: 210 gr∙
• Certificate Rumen fluid resistant – materials tested by the German Agricultural
Society (Deutsche Landwirtschafts-Gesellschaft DLG)
• Antenna: Internal
• Readout range: typically 50 meters; up to 300 meters*
• Memory: Internal measurement value memory: 6 days (24h/day); after 6 days
old data will be replaced by new data
• Battery: Lithium Metal Battery
• Battery life: up to 4 years
• Measurement intervall:10 min (for temperature and activity)
• Temperature:
o Measurement range: 20 – 60 °C/68 – 140 °F
o Measurement resolution: 0,01 °C/0,02 °F
o Measurement accuracy:
at 30 – 50 °C/86 – 122 °F: ± 0,1 °C/± 0,18 °F∙
other temperatures: ± 0,30 °C/± 0,54 °F∙
• Activity index: 0 to 100
• Rumination activity: 0 to 50 % in 24h
*depending on farm layout, country regulations obstructions, surroundings