User's Manual

7
Technical Details
Model: UX-2042
Dimensions:105 × 35 mm (length × diameter)
Weight: 210 gr∙
Certificate Rumen fluid resistant materials tested by the German Agricultural
Society (Deutsche Landwirtschafts-Gesellschaft DLG)
Antenna: Internal
Readout range: typically 50 meters; up to 300 meters*
Memory: Internal measurement value memory: 6 days (24h/day); after 6 days
old data will be replaced by new data
Battery: Lithium Metal Battery
Battery life: up to 4 years
Measurement intervall:10 min (for temperature and activity)
Temperature:
o Measurement range: 20 60 °C/68 140 °F
o Measurement resolution: 0,01 °C/0,02 °F
o Measurement accuracy:
at 30 50 °C/86 122 °F: ± 0,1 °C/± 0,18 °F∙
other temperatures: ± 0,30 °C/± 0,54 °F∙
Activity index: 0 to 100
Rumination activity: 0 to 50 % in 24h
*depending on farm layout, country regulations obstructions, surroundings