Datasheet

JIS Symbol
Filter Regulator Lubricator
+
+
+
+
+
+
+
+
+
Air Combination
Filter Regulator + Lubricator
AC10A to AC60A
AC A
30 03 DE
Note 4)
10 20 30 40 50 60
Body size
Description
Metric thread (M5)
Rc
NPT
G
Symbol
N
Note 1)
F
Note 2)
C
D
Thread type
Float type
auto drain
M5
1/8
1/4
3/8
1/2
3/4
1
M5
01
02
03
04
06
10
Port size
a
Without auto drain
Float type auto drain (N.C.)
Float type auto drain (N.O.)
E
G
M
E1
E2
E3
E4
Pressure
gauge
Digital
pressure
switch
b
Without pressure gauge
Square embedded type pressure gauge (with limit indicator)
Round type pressure gauge (without limit indicator)
Round type pressure gauge (with limit indicator)
Round type pressure gauge (with colour zone)
Output: NPN output / Electrical entry: Wiring bottom entry
Output: NPN output / Electrical entry: Wiring top entry
Output: PNP output / Electrical entry: Wiring bottom entry
Output: PNP output / Electrical entry: Wiring top entry
K
Check valve
c
Without attachment
Mounting position: AW+K+AL
Nil
S
Note 5)
Pressure
switch
d
Without attachment
Mounting position: AW+S+AL
V
3-port valve for
residual pressure
release
e
Without attachment
Mounting position: AW+AL+
V
1
Note 6)
Set pressure
f
0.05 to 0.85 MPa setting
0.02 to 0.2 MPa setting
J
Note 8)
W
Note 9)
Filter regulator
drain port
Note 7)
h
With drain cock
Drain guide 1/8
Drain guide 1/4
Drain cock with barb fitting: For ø6 x ø4 nylon tube
2
6
8
C
6C
Bowl
g
Polycarbonate bowl
Metal bowl
Nylon bowl
Metal bowl with level gauge
With bowl guard
Nylon bowl with bowl guard
How to Order
Option/Semi-standard: Select one each for a to l.
Option/Attachment/Semi-standard symbol: When more than one
specification is required, indicate in ascending alphanumeric order.
Example) AC30A-F03DE1-KSV-136NR
Semi-standard Attachment
Note 3)
Option
Standard Specifications
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch (AC20A to AC60A).
Note 2) –5 to 50
°C for the products with the digital pressure switch
Note 3) Not applicable to the AC10A.
+
+
+
Air
–5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
Set pressure + 0.05 MPa
Note 3)
[at relief flow rate of 0.1 l/min (ANR)]
5 µm
Class 1 turbine oil (ISO VG32)
Polycarbonate
Relieving type
Semi-standard
0.59
Standard
0.05 to 0.85 MPa
0.75 1.41 1.46 3.33 3.40
Model
Component
Port size
Pressure gauge port size
Note 1)
Fluid
Ambient and fluid temperature
Note 2)
Proof pressure
Maximum operating pressure
Set pressure range
Relief pressure
Nominal filtration rating
Recommended lubricant
Bowl material
Bowl guard
Regulator construction
Mass (kg)
Filter regulator
Lubricator
1/8 1/4
AC60A
AW60
AL60
1
AC50A
AW60
AL50
3/4, 1
AC40A-06
AW40-06
AL40-06
3/4
AC40A
AW40
AL40
1/4, 3/8, 1/2
AC30A
AW30
AL30
1/4, 3/8
AC20A
AW20
AL20
1/8, 1/4
AC10A
AW10
AL10
M5
1/16
0.05 to 0.7 MPa
0.20
Note 1) Drain guide is NPT1/8 (applicable to the AC20A)
and NPT1/4 (applicable to the AC30A to AC60A).
The auto drain port comes with a ø3/8" one-touch
fitting (applicable to the AC30A to AC60A).
Note 2) Drain guide is G1/8 (applicable to the AC20A)
and G1/4 (applicable to the AC30A to AC60A).
Note 3) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 4) Not available with piping port size: 06.
Note 5) The bracket position varies depending on the
pressure switch mounting.
Note 6) The only difference from the standard
specifications is the adjusting spring for the
regulator. It does not restrict the setting of 0.2
MPa or more. When the pressure gauge is
attached, a 0.2 MPa pressure gauge will be fitted.
Note 7) Float type auto drain: The combination between C
or D is not available with the drain port option.
Note 8) Without a valve function
Note 9) Metal bowl: The combination of 2 and 8 cannot be
selected with W.
Note 10) For thread type: M5 and NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is provided
for use in Japan.) The digital pressure switch will
be equipped with the unit conversion function,
setting to psi initially.
MPa and psi are shown together on the pressure
unit.
Note 11) For options: E1, E2, E3, E4. This product is for
overseas use only according to the new
Measurement Law. (The SI unit is provided for
use in Japan.)
Note 12)
: For thread type: M5 and NPT only
Note 13)
: Select with options: E1, E2, E3, E4.
AC40A
AC20A
3
Lubricator
lubricant
exhaust port
i
Without drain cock
Lubricator with drain cock
N
Exhaust
mechanism
j
Relieving type
Non-relieving type
R
Flow direction
k
Flow direction: Left to right
Flow direction: Right to left
Z
Note 10)
ZA
Note 11)
Pressure unit
l
Name plate and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Digital pressure switch: With unit conversion function
Semi-standard
Description
Symbol
Note 12) Note 12) Note 12) Note 12) Note 12) Note 12)
Note 13) Note 13) Note 13) Note 13) Note 13
)
10 20 30 40 50 60
Body size
Air Combination
Series AC10A to AC60A
8