Datasheet

IS1000M-20
IS1000M-30
IS1000M-40
IS1000M-50
IS1000M-60
Model
AC20
AC25, AC30
AC40
AC40-06
AC50, AC55, AC60
Applicable model
A
11
13
15
17
22
B
76
86
95
99
92.5
C
66
72
77
79
68.5
D
28
30
36
44
53
Note) Separate spacers are required for modular unit.
D
B
C
500
23
Center of
F.R.L. body
A
15
A compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line.
Using a T-interface facilitates the redirection of air flow.
30IS1000M
Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)
Pressure Switch: (S)
T-interface: (T) M5, 1/8, 1/4, 3/8, 1/2
Caution on Mounting
AC10, AC10B
AC20, AC20B,
AC20C
AC25, AC25B,
AC25C, AC30,
AC30B, AC30C
AC40, AC40B,
AC40C
AC40-06, AC40B-06
AC40C-06
AC50, AC55,
AC60, AC50B,
AC55B, AC60B
Applicable model
Y110-M5
Y210-01
Y210-02
Y310-01
Y310-02
Y410-02
Y410-03
Y510-02
Y510-03
Y610-03
Y610-04
Port size
M5
1/8
1/4
1/8
1/4
1/4
3/8
1/4
3/8
3/8
1/2
Model
Note 1) in model numbers indicates a thread type. No indication is necessary for Rc;
however, indicate N for NPT, and F for G.
Note 2) Separate interfaces are required for modular unit.
Refer to the attachment table on page 22 for standard port sizes when using with the AC.
C
12
32
39
44
46
57
D
14
28
30
36
44
53
E
8
19
19
24
24
30
B
19
42
53
62
66
81
A
11
15
15
19
19
22
If a T-interface is used on the IN side of the lubricator, lubricant
may be mixed. Use the AKM series check valve to avoid such
possibility.
T-interface
D
Port size
Center of
F.R.L. body
B
C
E
A
Octagon
Pressure switch
JIS Symbol
Body size
Description
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
MPa
MPa/psi dual scale
MPa
MPa/psi dual scale
MPa
MPa/psi dual scale
MPa
MPa/psi dual scale
0.5 m
0.5
m
0.5
m
0.5
m
3
m
3
m
3
m
3
m
Set pressure
range
Pressure displayLead wire length
Symbol
P
Note)
X202
X202-P
Note)
X201
X201-P
Note)
X215
X215-P
Note)
Option
20 30 40 50 60
Specifications
Fluid
Ambient and fluid temperature
Proof pressure
Maximum operating pressure
Set pressure range (when OFF)
Hysteresis
Air
–5 to 60°C (with no freezing)
1.0 MPa
0.7 MPa
0.1 to 0.4 MPa
0.08 MPa or less
Switch Characteristics
Contact point configuration
Maximum contact point capacity
Operating voltage: AC, DC
Maximum operating current
1a
2 VA (AC), 2 W (DC)
100 V or less
12 V to 24 VAC, DC: 50 mA
48 VAC, DC: 40 mA
100 VAC, DC: 20 mA
Note) For detailed specifications, please refer to Best Pneumatics, IS1000 Series.
Series AC
Residual Pressure Release 3 Port Valve: (V)
With the use of a 3-port valve for residual pressure release, pressure left in the line can be easily exhausted.
Cross Spacer: M5, 1/8, 1/4, 3/8, 1/2
Model
VHS20
VHS30
VHS40
VHS40-06
VHS50
G
22
21
26
H
45
55
63
69
81
A
40
53
70
75
90
AA
34
46
63
67
78
B
59
78
107
110
134
C
20
29
39
42
53
D
45
55
58
65
76
E
33
42
44
50
61
F
28
30
36
44
54
1.
If a tube, stop valve or silencer is connected to the ex-
haust port of the VHS20/30, the effective sectional
area should be larger than the figure indicated in the
following table, to prevent malfunction caused by back
pressure. (This is not applicable to the VHS40/50.)
Caution on Mounting
Note) Use an air filter on the IN side for operating protection.
Specifications
Model
VHS20
VHS30
Effective area (mm
2
)
5
5
Model
VHS20
VHS30
VHS40
VHS40-06
VHS50
IN, OUT
Effective area (mm
2
) ( ): Cv factor
INOUT
10 (0.54)
14 (0.76)
16 (0.87)
31 (1.68)
27 (1.46)
38 (2.06)
55 (2.98)
77 (1.73)
82 (4.44)
125 (6.78)
OUTEXH
11 (0.60)
16 (0.87)
14 (0.76)
29 (1.57)
36 (1.95)
40 (2.17)
42 (2.28)
49 (2.66)
50 (2.71)
53 (2.87)
EXH
Port size
1/8
1/4
1/4
3/8
1/4
3/8
1/2
3/4
3/4
1
JIS Symbol
(A)
2
3
(R)
1
(P)
OUTIN
EXH.
C
B
AA
SUP
30 03VHS
Note) For thread type: NPT only. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)
Pipings are possible in all 4 directions.
IN/OUT ports are not machined for threads.
Please contact SMC if threaded (machined) ports are required.
Cross spacer
Model
Y14-M5
Y24-01
Y24-02
Y34-01
Y34-02
Y44-02
Y44-03
Y54-03
Y54-04
Port size
M5
1/8
1/4
1/8
1/4
1/4
3/8
3/8
1/2
Applicable model
AC10
AC20
AC25, AC30
AC40
AC40-06
E: 4 x Rc
F: Without thread
A
23
40
49
60
72
B
16
40
43
48
62
C
14
22
28
36
40
D
25
40
48
54
62
Note 1) in model numbers indicates a thread type. No indication is necessary for Rc;
however, indicate N for NPT, and F for G.
Note 2) If threaded ports are required, they are available as a special order.
Please contact SMC.
1. When mounting a cross interface directly on the IN side of the lubricator, be sure to
use the AKM series check valve between the lubricator and cross interface.
2. Factory mounting of a cross interface on the AC model is available as a special
order.
E
D
E
E
E
Port size
B
C
A
Center of F.R.L. body
F
F
Caution on Mounting
Body size
20 30 40 50
• Semi-standard: Select one each for a to b.
Semi-standard symbol: When more than one specification is required, indicate in ascending alphabetic order.
Example) VHS30-03-RZ
+
+
+
DescriptionSymbol
N
Note)
F
Note)
Thread type
R
Flow direction
Z
Note)
Pressure unit
Rc
NPT
G
Flow direction: Left to right
Flow direction: Right to left
Name plate in imperial units: MPa
Name plate in imperial units: psi
01
02
03
04
06
10
Port size
1/8
1/4
3/8
1/2
3/4
1
Semi-
standard
a
b
3-port valve for
residual pressure
release
ø
H
2 x ø10
D
A
E
F
G
Lockable at the
time of exhaust
1/8
1/4
3/8
1/2
1/2
Attachments
Series AC
24