Datasheet

Flow Characteristics (Representative values)
: When saturated with oil
: Initial state
AFM20
50 100 150 200
0.04
0.03
0.02
0.01
0
0
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
P
1
= 0.3 MPa
P
1
= 0.5 MPa
P
1
=
0.7 MPa
P
1
=
0.3 MPa
P
1
=
0.5 MPa
P
1
=
0.7 MPa
AFD20
50 100
0.04
0.03
0.02
0.01
0
0
Flow rate (l/min (ANR))
Pressure drop (MPa)
P
1 = 0.3 MPa
P
1
= 0.5 MPa
P
1
=
0.7 MPa
P
1
= 0.3 MPa
P
1
= 0.5 MPa
P
1
=
0.7 MP
a
100 200 300 500400 600
0.04
0.03
0.02
0.01
0
0
AFM30
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
P
1
= 0.3 MPa
P
1
= 0.5
M
Pa
P
1
=
0.7 MPa
P
1
= 0.3 MPa
P
1
= 0.5 MPa
P
1
=
0.7 MPa
AFD30
50 100 150 200
0.04
0.03
0.02
0.01
0
0
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
P
1
= 0.3 MPa
P
1
= 0.5 MPa
P
1
=
0.7 MPa
P
1
= 0.3 MP
a
P
1
= 0.5 MPa
P
1
=
0.7 MPa
200 800 1000400 600
0.04
0.03
0.02
0.01
0
0
AFM40
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
P
1
= 0.3 MPa
P
1 = 0.5 MPa
P
1
=
0.7 MPa
P
1
= 0.3 MP
a
P
1
= 0.5 MPa
P
1
=
0.7 MPa
100 200 300 500400 600
0.04
0.03
0.02
0.01
0
0
AFD40
Flow rate (
l
/min (ANR))
Pressure drop (MPa)
P
1
= 0.3 MPa
P
1
= 0.5 MPa
P
1
=
0.7 MPa
P
1
= 0.3 MPa
P
1
= 0.5 MPa
P
1
=
0.7 MPa
Air Supply
1. Install an air filter (AF series) as a pre-filter on the inlet side of
the mist separator to prevent premature clogging.
2. Install a mist separator (AFM series) as a pre-filter on the inlet
side of the micro mist separator to prevent premature clogging.
3. Do not install on the inlet side of the dryer as this can cause
premature clogging of the element.
Caution
Maintenance
1. Replace the element every 2 years or when the pressure drop
becomes 0.1 MPa, whichever comes first, to prevent damage
to the element.
Warning
Design
1. Design the system so that the mist separator is installed in a
pulsation-free location. The difference between internal and
external pressure inside the element should be kept within 0.1
MPa, as exceeding this value could cause damage.
Caution
Selection
1. Do not allow air flow that exceeds the rated flow. If the air flow
is allowed outside the range of the rated flow even momenta-
rily, drainage and lubricant may splash at the outlet side or
cause damage to the component.
2.
Do not use in a low pressure application (such as a blower).
F.R.L. unit has its own minimum operating pressure depending
on the equipment and is designed specifically to function with
compressed air. If used below the minimum operating pressure,
a loss of performance and malfunction can occur. Please contact
SMC if an application under such conditions cannot be avoided.
Caution
Be sure to read this before handling. Refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A) for Safety Instruc-
tions and F.R.L. Units Precautions.
Specific Product Precautions
Series AFM20 to AFM40
Series AFD20 to AFD40
M5 x 0.8
Float type auto drain (N.C.)
Float type auto drain
ø10 one-touch
fitting
ø10 one-touch
fitting
N.C.
N.O.
q
e
w
r
Drain
OUTIN
Drain
q
e
w
r
OUTIN
Component Parts
No. Description
Body
Material
Zinc die-cast
Aluminum die-cast
Model
AFM20, AFD20
AFM30 to AFM40-06, AFD30 to AFD40-06
Platinum silver
Colour
1
No. Description
Element assembly
Bowl O-ring
Bowl assembly
Note 1)
Material
NBR
Polycarbonate
Part no.
AFM20
AFD20
AFM30
AFD30
AFM40
AFD40
AFM40-06
AFD40-06
AFM20P-060AS
AFD20P-060AS
C2SFP-260S
C2SF
AFM20 to 40
AFD20 to 40
AFM30P-060AS
AFD30P-060AS
C3SFP-260S
C3SF
Note 2)
AFM40P-060AS
AFD40P-060AS
C4SFP-260S
C4SF
Note 2)
2
3
4
Replacement Parts
Note 1) Bowl O-ring is included. Please contact SMC regarding the bowl assembly supply for psi and °F unit specifications.
Note 2) Bowl assembly for the AFM30 to AFM40-06 models and the AFD30 to AFD40-06 models comes with a bowl guard (steel band material).
Construction
AFM30 to AFM40-06
AFD30 to AFD40-06
AFM20
AFD20
Mist Separator
Series AFM20 to AFM40
Micro Mist Separator
Series AFD20 to AFD40
42