Specific Product Precautions
Selection
1. Residual pressure disposal (outlet pressure removal) is not
possible for the AR20 to AR60 even though the inlet pressure
is exhausted. When the residual pressure disposal is perfor-
med, use the regulator with a backflow function (AR20K to
AR60K).
Warning
Maintenance
1. When using the regulator with backflow function between a so-
lenoid valve and an actuator, check the pressure gauge perio-
dically. Sudden pressure fluctuations may shorten the durabi-
lity of the pressure gauge. A digital pressure gauge is recom-
mended for such situation or as deemed necessary.
Warning
Mounting and Adjustment
1. Set the regulator while verifying the displayed values of the in-
let and outlet pressure gauges. Turning the regulator knob ex-
cessively can cause damage to the internal parts.
2. The pressure gauge included with regulators for 0.02 to 0.2
MPa setting
is for up to 0.2 MPa use only (except the AR10).
Exceeding 0.2 MPa of pressure can damage the gauge.
3. Do not use tools on the pressure regulator knob as this may
cause damage. It must be operated manually.
Warning
1. Be sure to unlock the knob before adjusting the pressure and
lock it after setting the pressure. Failure to follow this procedu-
re can cause damage to the knob and the outlet pressure may
fluctuate.
Pull the pressure regulator knob to unlock. (You can visually
verify this with the “orange mark” that appears in the gap.)
Push the pressure regulator knob to lock. When the knob is
not easily locked, turn it left and right a little and then push it
(when the knob
is locked, the “orange mark”, i.e., the gap will
disappear).
2. A knob cover is available to prevent careless operation of the
knob. Refer to page 90 for details.
Caution
Orange mark
Be sure to read this before handling. Refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A) for Safety Instruc-
tions and F.R.L. Units Precautions.
Note 1) Assembly includes a bracket and set nuts
Note 2) Assembly includes a bracket and 2 mounting screws
Note 3) Please consult with SMC regarding the set nuts for the AR50(K) and AR60(K).
Note 4)
in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for NPT. Please contact SMC
regarding the connection thread NPT and pressure gauge supply for psi unit specifications.
Note 5) Pressure gauge for general purpose
Note 6) Including one O-ring and 2 mounting screws. [ ]: Pressure gauge cover only
Note 7) Lead wire with connector (2 m), adapter, lock pin, O-ring (1 pc.), mounting screw (2 pcs.) are attached. [ ]: Switch body only
Also, regarding how to order the digital pressure switch, please refer to page 89.
Options/Part No.
AR20P-270AS
AR20P-260S
AR10P-270AS
AR10P-260S
G27-10-R1
G27-10-R1
Note 5)
AR25P-270AS
AR25P-260S
G36-10-01
G36-2-
01
G36-10-
01-L
G36-2-
01-L
AR30P-270AS
AR30P-260S
AR40P-270AS
AR40P-260S
AR50P-270A
S
Note 2)
Note 3)
Note 3)
Standard
0.02 to 0.2 MPa setting
Standard
0.02 to 0.2 MPa setting
Standard
0.02 to 0.2 MPa setting
NPN output: Wiring bottom entry
NPN output: Wiring top entry
PNP output: Wiring bottom entry
PNP output: Wiring top entry
Model
Option
Bracket assembly
Note 1)
Set nut
Press-
ure
gauge
Note 4)
Note 4)
Note 6)
Digital
pressure
switch
AR10 AR25(K)AR20(K) AR30(K) AR40(K)
AR40(K)-06
AR50(K) AR60(K)
Round
type
Square
embedded
type
Round
type (with
colour zone)
G46-10-02
G46-2-
02
G46-10-
02-L
G46-2-
02-L
GC3-10AS [GC3P-010AS (Pressure gauge cover only)]
GC3-2AS [GC3P-010AS (Pressure gauge cover only)]
ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)]
Note 7)
ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)]
Note 7)
ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)]
Note 7)
ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)]
Note 7)
Series AR10 to AR60
Series AR20K to AR60K
Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa
0
0.5
0.6
0.4
0.3
0.2
0.1
0
AR25(K)
Rc3/8
Flow rate (l/min (ANR))
Outlet pressure (MPa)
500 1000 1500
0.6
0.5
0.4
0.3
0.2
0.1
0
0
Flow rate (
l
/min (ANR))
Outlet pressure (MPa)
AR40(K)
Rc1/2
1000 2000 3000
0
0.6
0.5
0.4
0.3
0.2
0.1
0
AR30(K)
Rc3/8
Flow rate
(
l
/min (ANR))
Outlet pressure (MPa)
500 1000 1500
AR50(K)
Rc1
0
0.6
0.5
0.4
0.3
0.2
0.1
0
Flow rate (l/min (ANR))
Outlet pressure (MPa)
5000 10000
0
0.6
0.5
0.4
0.3
0.2
0.1
0
AR40(K)-06
Rc3/4
Flow rate
(
l
/min (ANR))
Outlet pressure (MPa)
1000 2000 3000 4000 5000
0
0.6
0.5
0.4
0.3
0.2
0.1
0
AR20(K)
Rc1/4
Flow rate (
l
/min (ANR))
Outlet pressure (MPa)
200 400 600 800
0.6
0.5
0.4
0.3
0.2
0.1
0
0 25 50 7
5 100 125 150
AR10
M5
Flow rate (l/min (ANR))
Outlet pressure (MPa)
AR60(K)
Rc1
0
0.6
0.5
0.4
0.3
0.2
0.1
0
5000 10000
Flow rate (
l
/min (ANR))
Outlet pressure (MPa)
Regulator
Series AR10 to AR60
Regulator with Backflow Function
Series AR20K to AR60K
50