Datasheet

How to Order
AW
30 03 BEK
Option/Semi-standard: Select one each for a to i.
Option/Semi-standard symbol: When more
than one specification is required, indicate in
ascending alphanumeric order.
Example) AW30K-03BE-1N
JIS Symbol
Filter Regulator
Filter Regulator with
Backflow Function
Example)
When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual
pressure release of the outlet side can be ensured for a safety purpose.
Integrated filter and regulator units save space and require less piping.
With the backflow function it incorporates a mechanism to exhaust the air pressure in
the outlet side reliably and quickly.
+
+
+
+
+
Body size
Description
Without backflow function
With backflow function
Symbol
K
Note 1)
E
G
M
E1
Note 6)
E2
Note 6)
E3
Note 6)
E4
Note 6)
C
D
N
Note 2)
F
Note 3)
With backflow
function
Thread type
Pressure
gauge
Digital
pressure
switch
Float type
auto drain
Metric thread (M5)
Rc
NPT
G
Without auto drain
Float type auto drain (N.C.)
Float type auto drain (N.O.)
Without pressure gauge
Square embedded type pressure gauge (with limit indicator)
Round type pressure gauge (without limit indicator)
Round type pressure gauge (with limit indicator)
Round type pressure gauge (with colour zone)
Output: NPN output / Electrical entry: Wiring bottom entry
Output: NPN output / Electrical entry: Wiring top entry
Output: PNP output / Electrical entry: Wiring bottom entry
Output: PNP output / Electrical entry: Wiring top entry
M5
01
02
03
04
06
10
Port size
M5
1/8
1/4
3/8
1/2
3/4
1
c
b
10 20 30 40 60
B
Note 5)
H
Mounting
Without mounting option
With bracket
With set nut (for panel fitting)
a
+
+
2
6
8
C
6C
Bowl
Note 7)
1
Note 8)
Set pressure
Polycarbonate bowl
Metal bowl
Nylon bowl
Metal bowl with level gauge
With bowl guard
Nylon bowl with bowl guard
0.05 to 0.85 MPa setting
0.02 to 0.2 MPa setting
e
d
Made to Order
Refer to page 75 through
to 78 for details.
Filter Regulator
AW10 to AW60
Filter Regulator with Backflow Function
AW20K to AW60K
Semi-standard
Note 4)
Option
Model
Port size
Pressure gauge port size
Note 1)
Fluid
Ambient and fluid temperature
Note 3)
Proof pressure
Maximum operating pressure
Set pressure range
Relief pressure
Note 4)
Nominal filtration rating
Drain capacity (cm
3
)
Bowl material
Bowl guard
Construction
Mass (kg)
AW10
M5 x 0.8
1/16
Note 2)
0.05 to 0.7 MPa
2.5
0.09
AW20(K)
1/8, 1/4
8
Semi-standard
0.32
AW30(K)
1/4, 3/8
25
0.40
AW40(K)
1/4, 3/8, 1/2
0.05 to 0.85 MPa
45
0.72
AW40(K)-06
3/4
1/4
45
0.75
AW60(K)
3/4, 1
45
2.00
1/8
Air
–5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
Polycarbonate
Relieving type
Set pressure + 0.05 MPa [at relief flow rate of 0.1 l/min (ANR)]
5 µm
Standard
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type
pressure gauge (AW20(K) to AW60(K)).
Note 2) Use a bushing (part no:131368) when connecting the R1/8 pressure gauge to the Rc1/16.
Note 3) –5 to 50°C for the products with the digital pressure switch
Note 4) Not applicable to the AW10.
AW20, AW20K AW40, AW40K
Standard Specifications
+
+
+
N
R
Exhaust
mechanism
Flow direction
Z
Note 12)
ZA
Note 13)
Pressure unit
Relieving type
Non-relieving type
Flow direction: Left to right
Flow direction: Right to left
Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi,
°F
Digital pressure switch: With unit conversion function
g
h
i
J
Note 10)
W
Note 11)
Drain port
Note 9)
With drain cock
Drain guide 1/8
Drain guide 1/4
Drain cock with barb fitting: For ø6 x ø4 nylon tube
f
Body size
Description
Symbol
Note 14) Note 14) Note 14) Note 14) Note 14)
Note 15) Note 15) Note 15) Note 15)
10 20 30 40 60
Note 1) The AW10 type comes with a backflow function
as a standard feature. (K is not available.) When
using the AW10 type as w/ backflow function,
backflow may not occur with the set pressure 0.15
MPa or less. Please set the inlet pressure to at
least 0.05 MPa higher than the set pressure.
Note 2) Drain guide is NPT1/8 (applicable to the
AW20(K)) and NPT1/4 (applicable to the AW30(K)
to AW60(K)). The auto drain port comes with
ø3/8" one-touch fitting (applicable to the AW30(K)
to AW60(K)).
Note 3)
Drain guide is G1/8 (applicable to the AW20(K))
and G1/4 (applicable to the AW30(K) to AW60(K)).
Note 4) Option B, G, H and M are not assembled and
supplied loose at the time of shipment.
Note 5) Assembly of a bracket and set nuts (AW10,
AW20(K) to AW40(K))
Includes 2 mounting screws for the AW60(K)
Note 6) When choosing with H (panel mount), the
installation space for lead wires will be limited. In
this case, select “wiring top entry” for the electrical
entry.
Note 7) Only the AW10 has a pressure setting of 0.05 to
0.7 MPa.
Note 8) The only difference from the standard
specifications is the adjusting spring for the
regulator. It does not restrict the setting of 0.2
MPa or more. When the pressure gauge is
attached, a 0.2 MPa pressure gauge will be fitted.
Note 9) Float type auto drain: The combination between C
or D is not available with the drain port options.
Note 10) Without a valve function
Note 11) Metal bowl: The combination of 2 cannot be
selected with W.
Note 12) For thread type: M5 and NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is provided
for use in Japan.) The digital pressure switch will
be equipped with the unit conversion function,
setting to psi initially.
Note 13) For options: E1, E2, E3, E4. This product is for
overseas use only according to the new
Measurement Law. (The SI unit is provided for
use in Japan.)
Note 14)
: For thread type: M5 and NPT only
Note 15)
: Select with options: E1, E2, E3, E4.
Semi-standard
Filter Regulator
Series AW10 to AW60
Filter Regulator with Backflow Function
Series AW20K to AW60K
68