Datasheet

Specifications
Proof pressure
Maximum operating pressure
Set pressure range
1.5 MPa
1.0 MPa
0.05 to 0.4 MPa
Applicable Model
Port size
Model
AW10 AW30(K) AW40(K)
AW40(K)-06
M5
AW20(K)
1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4
AW60(K)
3/4, 1
Applicable Model/Drain Capacity
Port size
Drain capacity (cm
3
)
Model
AW10
M5
9
AW30(K)
1/4, 3/8
43
AW40(K)
1/4, 3/8, 1/2
AW40(K)-06
3/4
AW20(K)
1/8, 1/4
19
88
AW60(K)
3/4, 1
30
AW
X40603
Note 1) The AW10 type comes with a backflow function as a standard feature. (K is not
available.) When using the AW10 type as w/ backflow function, backflow may
not occur with the set pressure 0.15 MPa or less. Please set the inlet pressure
to at least 0.05 MPa higher than the set pressure.
Note 2) Drain guide is NPT1/8 (applicable to the AW20(K)) and NPT1/4 (applicable to
the AW30(K) to AW60(K)). The auto drain port comes with a ø3/8" one-touch
fitting (applicable to the AW30(K) to AW60(K)).
Note 3) Drain guide is G1/8 (applicable to the AW20(K)) and G1/4 (applicable to the
AW30(K) to AW60(K)).
Note 4) Option B, G, H and M are not assembled and supplied loose at the time of
shipment.
Note 5) Assembly of a bracket and set nuts. (AW10, AW20(K) to AW40(K)).
Includes 2 mounting screws for the AW60(K)
Note 6) When choosing with H (panel mount), the installation space for lead wires will
not be secured. In this case, select wiring down entry for the electrial entry.
e 0.4 MPa Setting r Long Bowl
The maximum set pressure is 0.4 MPa. When a pressure gauge
is included, the display will show a range from 0 to 0.4 MPa.
Drain capacity is greater than that of standard models.
10 20 30 40 60
Body size
Description
Without backflow function
With backflow function
Symbol
K
Note 1)
With backflow
function
M5
1/8
1/4
3/8
1/2
3/4
1
M5
01
02
03
04
06
10
Port size
Without mounting option
With bracket
With set nut (for panel fitting)
B
Note 5)
H
E
G
M
E1
Note 6)
E2
Note 6)
E3
Note 6)
E4
Note 6)
Mounting
a
Without pressure gauge
Square embedded type pressure gauge (with limit indicator)
Round type pressure gauge (without limit indicator)
Round type pressure gauge (with limit indicator)
Round type pressure gauge (with colour zone)
Output: NPN output / Electrical entry: Wiring bottom entry
Output: NPN output / Electrical entry: Wiring top entry
Output: PNP output / Electrical entry: Wiring bottom entry
Output: PNP output / Electrical entry: Wiring top entry
Pressure
gauge
Digital
pressure
switch
c
+
+
+
10 20 30 40 60
Without auto drain
Float type auto drain (N.C.)
Float type auto drain (N.O.)
C
D
Float type
auto drain
b
+
+
Body size
Metric thread (M5)
Rc
NPT
G
N
Note 2)
F
Note 3)
Thread type
Filter Regulator
AW10 to AW60
Filter Regulator with Backflow Function
AW20K to AW60K
Made to Order
Please contact SMC for detailed dimensions, specifications, and lead times.
How to Order
X406
X64
0.4 MPa setting
Long bowl
0.4 MPa Setting Long Bowl
Note) Please consult SMC for dimensions.
Option/Semi-standard: Select one each for a to i.
Option/Semi-standard symbol: When more than one specification is required, indicate in
ascending alphanumeric order.
Example) AW30K-03BE-2N-X406
Option
Note 4)
10 20 30 40 60
Body size
DescriptionSymbol
Polycarbonate bowl
Metal bowl
Nylon bowl
Metal bowl with level gauge
With bowl guard
Nylon bowl with bowl guard
2
6
8
C
6C
Bowle
Flow direction: Left to right
Flow direction: Right to left
Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi,
°F
Digital pressure switch: With unit conversion function
R
Z
Note 12)
ZA
Note 13)
Flow directionh
Relieving type
Non-relieving type
N
Exhaust
mechanism
g
Pressure unit
i
+
+
+
+
10 20 30 40 60
With drain cock
Drain guide 1/8
Drain guide 1/4
Drain cock with barb fitting: For ø6 x ø4 nylon tube
J
Note 10)
W
Note 11)
Drain portf
Note 14) Note 14)
Note 15)
Note 14)
Note 15)
Note 14)
Note 15)
Note 14)
Note 15)
Note 14) Note 14)
Note 15)
Note 14)
Note 15)
Note 14)
Note 15)
Note 14
)
Note 15
)
Body size
0.4 MPa Setting Long Bowl
Note 9)
Note 7) Only the AW10 has a pressure setting of 0.05 to 0.7 MPa.
Note 8) The only difference from the standard specifications is the adjusting spring for
the regulator. It does not restrict the setting of 0.2 MPa or more. When the
pressure gauge is attached, a 0.2 MPa pressure gauge will be fitted.
Note 9) Float type auto drain: The combination between C or D is not available with the
drain port option.
Note 10) Without a valve function
Note 11) Metal bowl: The combination of 2 and 8 cannot be selected with W.
Note 12) For thread type: M5 and NPT. This product is for overseas use only according
to the new Measurement Law. (The SI unit type is provided for use in Japan.)
The digital pressure switch will be equipped with the unit conversion function,
setting to psi initially.
Note 13) For options: E1, E2, E3, E4. This product is for overseas use only according to
the new Measurement Law. (The SI unit is provided for use in Japan.)
Note 14)
: For thread type: M5 and NPT only
Note 15)
: Select with options: E1, E2, E3, E4.
0.05 to 0.85 MPa setting
0.02 to 0.2 MPa setting
Note 7)
1
Note 8)
Set pressure
d
+
Semi-standard
Filter Regulator
Series AW10 to AW60
Filter Regulator with Backflow Function
Series AW20K to AW60K
78