Datasheet

How to Order
AWM
30 03 BE
AWD
30 03 BE
JIS Symbol
Mist Separator
Regulator
Micro Mist Separator
Regulator
The AWM series is made up of a regulator and a mist separator to provide optimum re-
sults in applications such as clean air blow operations. (Nominal filtration rating: 0.3
µm)
The AWD series is made up of a regulator and a micro mist separator to provide opti-
mum results in applications such as ultraclean air blow operations. (Nominal filtration
rating: 0.01 µm)
+
+
+
+
Body size
Description
Symbol
N
Note 1)
F
Note 2)
Thread type
Rc
NPT
G
01
02
03
04
Port size
1/8
1/4
3/8
1/2
30 4020
E
G
M
1
Note 5)
E2
Note 5)
E3
Note 5)
E4
Note 5)
Pressure
gauge
Digital
pressure
switch
Without pressure gauge
Square embedded type pressure gauge
Round type pressure gauge
Round type pressure gauge (with colour zone)
Output: NPN output / Electrical entry: Wiring bottom entry
Output: NPN output / Electrical entry: Wiring top entry
Output: PNP output / Electrical entry: Wiring bottom entry
Output: PNP output / Electrical entry: Wiring top entry
c
C
D
Float type
auto drain
Without auto drain
Float type auto drain (N.C.)
Float type auto drain (N.O.)
b
B
Note 4)
H
Mounting
Without mounting option
With bracket
With set nut
a
+
+
+
1
Note 7)
Set pressure
0.05 to 0.85 MPa setting
0.02 to 0.2 MPa setting
d
J
Note 9)
W
Note 10)
Drain port
Note 8)
With drain cock
Drain guide 1/8
Drain guide 1/4
Drain cock with barb fitting: For ø6 x ø4 nylon tube
f
2
6
8
C
6C
Bowl
Polycarbonate bowl
Metal bowl
Nylon bowl
Metal bowl with level gauge
With bowl guard
Nylon bowl with bowl guard
e
Made to Order
For details, refer to pages 87 and 88.
Mist Separator Regulator
AWM20 to AWM40
Micro Mist Separator Regulator
AWD20 to AWD40
• Option/Semi-standard: Select one each for a
to
i.
• Option/Semi-standard symbol: When more
than one specification is required, indicate in
ascending alphanumeric order.
Example) AWM30-03BE-1N
Note 6)
Semi-standard
Note 3)
Option
AWM20, AWD20 AWM40, AWD40
Standard Specifications
Model
Port size
Fluid
Proof pressure
Maximum operating pressure
Set pressure range
Pressure gauge port size
Note 1)
Ambient and fluid temperature
Note 2)
Nominal filtration rating
Rated flow (l/min (ANR))
Note 5)
Drain capacity (cm
3
)
Bowl material
Bowl guard
Construction
Mass (kg)
Outlet side oil mist
concentration
AWM20
AWD20
AWM20 to AWM40
AWD20 to AWD40
AWM20 to AWM40
AWD20 to AWD40
AWM20 to AWM40
AWD20 to AWD40
1/8, 1/4
150
90
8
Semi-standard
0.44
AWM30
AWD30
1/4, 3/8
Air
1.5 MPa
1.0 MPa
0.05 to 0.85 MPa
–5 to 60°C (with no freezing)
0.3 µm (99.9% filtered particle size)
0.01 µm (99.9% filtered particle size)
Max. 1.0
mg/m
3
(ANR) ( 0.8 ppm)
Note 3) Note 4)
Max. 1.0 mg/m
3
(ANR) (Before saturated with 0.001 mg/m
3
(ANR) or less 0.008 ppm)
Note 3) Note 4)
330
180
25
Polycarbonate
Relieving type
0.59
AWM40
AWD40
1/4, 3/8, 1/2
1/4
820
450
45
1.25
1/8
Standard
Body size
Description
Symbol
30 4020
+
+
N
Exhaust
mechanism
Relieving type
Non-relieving type
g
R
Flow direction
Flow direction: Left to right
Flow direction: Right to left
h
Z
Note 11)
ZA
Note 12)
Pressure unit
Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi,
°F
Digital pressure switch: With unit conversion function
i
Note 1) Drain guide is NPT1/8 (applicable to the AWM20,
AWD20) and NPT1/4 (applicable to the AWM30
to AWM40, AWD30 to AWD40). The auto drain
port comes with a ø3/8" one-touch fitting
(applicable to the AWM30 to AWM40, AWD30 to
AWD40).
Note 2) Drain guide is G1/8 (applicable to the AWM20,
AWD20) and G1/4 (applicable to the AWM30 to
AWM40, AWD30 to AWD40).
Note 3) Option B, G, H and M are not assembled and
supplied loose at the time of shipment.
Note 4) Assembly includes a bracket and set nuts
Note 5) When choosing with H (panel mount), the
installation space for lead wires will not be
secured. In this case, select wiring bottom entry
for the electrical entry.
Note 6) Float type auto drain: when used in combination
with C or D, minimum set pressure is: N.O.
type0.1 MPa; N.C. type0.1 MPa (AD27) and
0.15 MPa (AD37/47).
Note 7) The only difference from the standard
specifications is the adjusting spring for the
regulator. It does not restrict the setting of 0.2
MPa or more. When the pressure gauge is
attached, a 0.2 MPa pressure gauge will be fitted.
Note 8) Float type auto drain: The combination between C
or D is not available with the drain port option.
Note 9) Without a valve function.
Note 10) Metal bowl: The combination of 2 and 8 cannot
be selected with W.
Note 11) For thread type: NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is provided
for use in Japan.) The digital pressure switch will
be equipped with the unit conversion function,
setting to psi initially.
Note 12) For options: E1, E2, E3, E4. This product is for
overseas use only according to the new
Measurement Law. (The SI unit is provided for
use in Japan.)
Note 13)
: For thread type: NPT only
Note 14)
: Select with options: E1, E2, E3, E4.
Semi-standard
Note 13)
Note 14)
Note 13)
Note 14)
Note 13)
Note 14)
Note 1) Pressure gauge connection threads are not available for
F.R.L. unit with a square embedded type pressure gauge.
Note 2) –5 to 50
°C for the products with the digital pressure switch.
Note 3) When the compressor oil mist discharge concentration is
30 mg/m
3
(ANR).
Note 4) Bowl O-ring and other O-rings are slightly lubricated.
Note 5) Conditions: Mist separator inlet pressure: 0.7 MPa; outlet pressure: 0.5 MPa. The rated flow varies
depending on the inlet pressure. Keep the air flow within the rated flow to prevent an outflow of
lubricant to the outlet side.
Mist Separator Regulator
Series AWM20 to AWM40
Micro Mist Separator Regulator
Series AWD20 to AWD40
79