Brochure

AC40C-AAC20C-A
Description
Symbol
25 30 4020
Body size
q
1/8
Air
– 5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
0.05 MPa
0.05 to 0.7 MPa
AF: 5 µm, AFM: 0.3 µm (99.9% filtered particle size)
MAX 1.0 mg/m
3
(ANR) (0.8 ppm)
Note 2) Note 3)
Polycarbonate
Relieving type
450
0.67
200
Semi-standard (Steel)
0.38
Standard (Polycarbonate)
450
0.82
1100
1.26
1100
1.42
Model
Component
Port size
Pressure gauge port size
Fluid
Ambient and fluid temperature
Proof pressure
Maximum operating pressure
Minimum operating pressure
Set pressure range
Nominal filtration rating
Outlet side oil mist concentration
Rated flow (L/min (ANR))
Note 1)
Bowl material
Bowl guard
Regulator construction
Weight (kg)
Air filter
Mist separator
Regulator
AC40C-06-A
AF40-06-A
AFM40-06-A
AR40-06-A
3/4
AC40C-A
AF40-A
AFM40-A
AR40-A
1/4, 3/8, 1/2
AC30C-A
AF30-A
AFM30-A
AR30-A
1/4, 3/8
AC25C-A
AF30-A
AFM30-A
AR25-A
1/4, 3/8
AC20C-A
AF20-A
AFM20-A
AR20-A
1/8, 1/4
Note 1) Conditions: Mist separator inlet pressure: 0.7 MPa; The rated flow varies depending on the inlet pressure.
Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side.
Note 2) When the compressor oil mist discharge concentration is 30 mg/m
3
(ANR).
Note 3) Bowl O-ring and other O-rings are slightly lubricated.
Standard Specifications
y
Nil
Z
Note 9)
Pressure unit
Semi-standard
j
Note 10)
Note 10)
Note 10)
Note 10)
Name plate and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Nil
R
Flow directioni
Flow direction: Left to right
Flow direction: Right to left
+
Note 1) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 2) When pressure is not applied, condensate
which does not start the auto drain
mechanism will be left in the bowl. Releasing
the residual condensate before ending
operations for the day is recommended.
Note 3) If the compressor is small (0.75 kW,
discharge flow is less than 100 L/min[ANR]),
air leakage from the drain cock may occur
during start of operations. N.C. type is
recommended.
Note 4) When the pressure gauge is attached, a
1.0 MPa pressure gauge will be fitted for
standard (0.7 MPa) type. 0.4 MPa pressure
gauge for 0.2 MPa type.
Note 5)
The bracket position varies depending on the
T-shaped spacer or pressure switch mounting.
Note 6) Make sure that the outlet pressure is
released to atmospheric pressure using a
pressure gauge.
Note 7) Pressure can be set higher than the
specification pressure in some cases, but
use pressure within the specification range.
Note 8) Without a valve function.
Note 9) For thread type: NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is
provided for use in Japan.)
MPa and psi are shown together on the
pressure unit.
Round pressure gauge (with color zone):
Cannot be used with M. Available by request
for special.
Note 10) : For thread type: NPT only.
16
Air Combination
Series AC20C-A to AC40C-A
AC
AFARALAWALAFARAFAFMARAWAFM
AF
AFM / AFD
ARALAW Attachment