Datasheet

31
Series AC
Piping adapter
Pressure switch with
piping adapter
B
D
A
Centre of
F.R.L.
body
Port size
0.2
0.4
0.1
0.3
MPa
Port
size
Centre of
F.R.L. body
DA
B
C
(23)
(13)
23 E
(5000)
(3000)
(500)
A piping adapter allows
installation/removal of the
component without removing the
piping and thus makes
maintenance easier.
Note) in model numbers indicates a pipe thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available as a
special order.
Specifi cations
Switch Characteristics
Piping Adapter: M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4
Symbol
IS10E A
30
q
03
rwe
Pressure Switch with Piping Adapter
Left Right
• Semi-standard: Select one each for a to d.
• Semi-standard symbol: When more than one specifi cation is required, indicate in alphanumeric order.
Example) IS10E-30N03-6PRZ
Note 1) Set pressure range of 6P (L, R, Z) is 0.2 to 0.6 MPa
(30 to 90 psi).
Note 2) For pipe thread type: NPT only.
Note 1) in the model numbers indicates a pipe thread type. No indication is necessary for Rc;
however, indicate N for NPT, and F for G.
Note 2) Cannot be mounted on the AC40-06-A.
Separate interfaces are required for modular unit.
The pressure switch on the AC40-06-A can be mounted by screwing IS10-01S into the piping
adapter E500-06-A-X501 (with top-face thread Rc1/8). Products with a premounted switch are
available as a special order. Please contact SMC regarding their availability.
Model
Note)
Port size
ABD
Applicable model
E100-M5-A
M5 x 0.8 10 14 14
AC10-A
E200-01-A
1/8
29.8 23.5 28
AC20-A
E200-02-A
1/4
E200-03-A
3/8
E300-02-A
1/4
31.8 30 30
AC25-A, AC30-A
E300-03-A
3/8
E300-04-A
1/2
E400-02-A
1/4
31.8 36 36
AC40-A
E400-03-A
3/8
E400-04-A
1/2
E400-06-A
3/4
E500-06-A
3/4 31.8 40 44
AC40-06-A
Symbol Description
Nq
Body size
20 30 40
Nw
Pipe thread type
Rc

N
Note)
NPT

F
Note)
G

+
Ne
Port size
01
1/8
——
02
1/4

03
3/8

04
1/2

06
3/4
——
+
Nr
Semi-standard
a
Set pressure
range
0.1 to 0.4 MPa

6
Note 1)
0.1 to 0.6 MPa

+
b
Lead wire
length
0.5 m

L
3 m

Z
5 m

+
c
Pressure unit of
the scale plate
MPa

P
Note 2)
MPa/psi dual scale

+
d
Mounting
position
Right

R
Left

Model
Note 1)
Port size
ABCDE
Applicable model
IS10E-2001-A
1/8
29.8 66.3 55.3 28 16
AC20-AIS10E-2002-A
1/4
IS10E-2003-A
3/8
IS10E-3002-A
1/4
31.8 72.8 58.8 30 13
AC25-A, AC30-AIS10E-3003-A
3/8
IS10E-3004-A
1/2
IS10E-4002-A
1/4
31.8 78.8 60.8 37 12.5
Note 2)
AC40-A
IS10E-4003-A
3/8
IS10E-4004-A
1/2
IS10E-4006-A
3/4
Contact point confi guration 1a
Maximum contact point capacity
2 VA (AC), 2 W (DC)
Operating voltage: AC, DC 100 V or less
Maximum operating current
12 V to 24 V AC, DC: 50 mA
48 V AC, DC: 40 mA
100 V AC, DC: 20 mA
Fluid Air
Ambient and fl uid temperature
−5 to 60°C (with no freezing)
Proof pressure 1.0 MPa
Maximum operating pressure
0.7 MPa
Set pressure range (when OFF)
0.1 to 0.4 MPa
Hysteresis 0.08 MPa or less
Right