Brochure

Part no.
G36-10-01
G36-4-01
G36-10-01-L
G36-4-01-L
G46-10-01
G46-4-01
G46-10-01-L
G46-4-01-L
Y300-A
Y300T-A
AKM3000-(01)-A
02-A
IS10M-30-A
Y310-(01)-A
02-A
VHS30-02A
03A
02
E300-03-A
04
02-A
IS10E-3003-A
04-A
Y34-01-A
02-A
For AC20-A
For AC20A-A
For AC20B-A
For AC20C-A
For AC20D-A
Y200-A
Y200T-A
AKM2000-01-A
(02)-A
IS10M-20-A
Y210-01-A
(02)-A
VHS20-01A
02A
01-A
E200-02-A
03-A
01-A
IS10E-2002-A
03-A
Y24-01-A
02-A
Y400-A
Y400T-A
AKM4000-(02)-A
03-A
IS10M-40-A
Y410-(02)-A
03-A
02A
VHS40-03A
04A
02-A
E400-03-A
04-A
06-A
02-A
IS10E-4003-A
04-A
06-A
Y44-02-A
03-A
Y500-A
Y500T-A
IS10M-50-A
Y510-(02)-A
03-A
VHS40-06A
E500-06-A
Y54-03-A
04-A
For AC25-A
For AC25B-A
For AC25C-A
For AC30-A
For AC30A-A
For AC30B-A
For AC30C-A
For AC30D-A
For AC40-A
For AC40A-A
For AC40B-A
For AC40C-A
For AC40D-A
For AC40-06-A
For AC40A-06-A
For AC40B-06-A
For AC40C-06-A
For AC40D-06-A
Model
Type
Round
type
Standard
0.02 to 0.2 MPa setting
Standard
0.02 to 0.2 MPa setting
Round type
(with color
zone)
Spacer
Spacer with bracket
Check valve
Note 2) Note 3)
Pressure switch
Note 3)
T-shaped spacer
Note 2) Note 3)
3-port valve for residual
pressure release
Note 3)
Piping adapter
Note 3)
Pressure switch with
piping adapter
Note 3)
Cross spacer
Note 3)
AKM2000-A
AKM3000-A
AKM4000-A
By-pass
port size
1/8, 1/4
1/8, 1/4
1/4, 3/8
AC20-A, AC20A-A
AC25-A
AC30-A, AC30A-A
AC40-A, AC40A-A
Note)
A
40
53
70
28
34
42
11
14
18
40
48
54
11
13
15
B C D E
Note) A pressure switch cannot be mounted on the AC40-06-A.
Refer to the attachment table above for standard
by-pass port sizes applicable to the AC.
A
D
Check valve
A check valve with intermediate air release port can be easily installed to prevent a backflow of lubricant when redirecting
the air flow and releasing the air on the outlet side of the regulator.
Check Valve: (K) 1/8, 1/4, 3/8
Note 1) in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT. Please contact SMC regarding the connection thread NPT and pressure gauge supply for psi unit specifications.
Note 2) For F.R.L. units, port sizes without ( ) are standard specifications.
Note 3) Separate interfaces are required for modular unit.
AKM2000-A
AKM3000-A
AKM4000-A
Model
Specifications
Effective area (mm
2
)
28
55
111
Be sure to use above check valves
when redirecting the air flow on the
inlet side of the lubricator. Threads for
IN and OUT ports are not machined.
JIS Symbol
B
C
E
OUT
By-pass port size for
redirecting air flow
IN
Applicable model
Options/Attachments Part No.
AKM A00
30 01
q ew
+
Description
Rc
NPT
G
Symbol
Nil
N
F
01
02
03
Thread
type
By-pass
port size
1/8
1/4
3/8
30 4020
Body size
q
w
e
Section
Option
Pressure gauge
Note 1)
Attachment
Model
22
Air Combination
Series AC
Options/Attachments
AC
AFARALAWALAFARAFAFMARAWAFM
AF
AFM / AFD
ARALAW Attachment