Datasheet

Standard Specifications
+
+
+
Air
– 5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
5 µm
Class 1 turbine oil (ISO VG32)
Polycarbonate
Relieving type
Semi-standard (Steel)
0.33
Standard (Polycarbonate)
0.05 to 0.7 MPa
0.66 1.22 1.34
Model
Component
Port size
Pressure gauge port size
Fluid
Ambient and fluid temperature
Proof pressure
Maximum operating pressure
Set pressure range
Nominal filtration rating
Recommended lubricant
Bowl material
Bowl guard
Regulator construction
Weight (kg)
Filter regulator
Lubricator
1/8
AC40A-06-A
AW40-06-A
AL40-06-A
3/4
AC40A-A
AW40-A
AL40-A
1/4, 3/8, 1/2
AC30A-A
AW30-A
AL30-A
1/4, 3/8
AC20A-A
AW20-A
AL20-A
1/8, 1/4
AC40A-A
AC20A-A
y
Nil
3
Note 9)
i
Without drain cock
Lubricator with drain cock
Nil
N
j
Relieving type
Non-relieving type
Nil
R
k
Flow direction: Left to right
Flow direction: Right to left
Nil
Z
Note 10)
l
Name plate and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Description
Symbol
Note 11)
Note 11)
Note 11)
20 30 40
Body size
q
Note 1) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 2) When pressure is not applied, condensate
which does not start the auto drain
mechanism will be left in the bowl. Releasing
the residual condensate before ending
operations for the day is recommended.
Note 3) If the compressor is small (0.75 kW,
discharge flow is less than 100 L/min[ANR]),
air leakage from the drain cock may occur
during start of operations. N.C. type is
recommended.
Note 4) When the pressure gauge is attached, a
1.0 MPa pressure gauge will be fitted for
standard (0.7 MPa) type. 0.4 MPa pressure
gauge for 0.2 MPa type.
Note 5) Not available with piping port size: 06.
Note 6) The bracket position varies depending on
the pressure switch mounting.
Note 7) Pressure can be set higher than the
specification pressure in some cases, but
use pressure within the specification range.
Note 8) Without a valve function
Note 9) When selected with the filter regulator drain
outlet W, the drain cock of the lubricator is
barb fitting.
Note 10) For thread type: NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is
provided for use in Japan.)
MPa and psi are shown together on the
pressure unit.
Round pressure gauge (with color zone):
Cannot be used with M. Available by
request for special.
Note 11) : For thread type: NPT only
Semi-standard
Lubricator
lubricant
exhaust port
Exhaust
mechanism
Flow direction
Pressure unit
8
Air Combination
Series AC20A-A to AC40A-A
AC
AFARALAWALAFARAFAFMARAWAFM
AF
AFM / AFD
ARALAW Attachment