Datasheet

Applicable model
Portsize
1/8
1/4
3/8
1/4
3/8
1/2
1/4
3/8
1/2
3/4
3/4
A piping adapter allows
installation/removal of the
component without removing
the piping and thus makes
maintenance easier.
Note) in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available
as a special order.
Piping adapter
B
D
A
Center of
F.R.L.
body
Port size
Specifications
Switch Characteristics
Fluid
Ambient and fluid temperature
Proof pressure
Maximum operating pressure
Set pressure range (when OFF)
Hysteresis
Piping Adapter: 1/8, 1/4, 3/8, 1/2, 3/4
Air
−5 to 60°C(with no freezing)
1.0 MPa
0.7 MPa
0.1 to 0.4 MPa
0.08 MPa or less
Contact point configuration
Maximum contact point capacity
Operating voltage: AC, DC
Maximum operating current
1a
2 VA(AC), 2 W(DC)
100 V or less
12 V to 24 V AC, DC: 50 mA
48 V AC, DC: 40 mA
100 V AC, DC: 20 mA
JIS Symbol
IS10E A
30
q
03
rw e
+
+
Body size
DescriptionSymbol
Nil
N
Note)
F
Note)
Thread type
Rc
NPT
G
01
02
03
04
06
Port size
1/8
1/4
3/8
1/2
3/4
20
30
40
Pressure Switch with Piping Adapter
DBA
28
30
36
44
23.5
30
36
40
29.8
31.8
31.8
31.8
Model
Note)
E200-01-A
E200-02-A
E200-03-A
E300-02-A
E300-03-A
E300-04-A
E400-02-A
E400-03-A
E400-04-A
E400-06-A
E500-06-A
D
500
B
C
A
23
Center of
F.R.L.
body
Port size
E
q
w
e
Pressure switch with
piping adapter
Left Right
•฀Semi-standard:฀Select฀one฀each฀for฀a to d.
•฀Semi-standard฀symbol:฀When฀more฀than฀one฀specification฀is฀required,฀indicate฀in฀alphanumeric฀order.
Example)฀IS10E-30N03-6PRZ
Note฀1)฀Set฀pressure฀range฀of฀6P฀(L,฀Z)฀is฀0.2฀to฀
0.6 MPa (30 to 90 psi).
Note 2) For thread type: NPT only. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is
provided for use in Japan.)
a
c
d
b
+
+
+
0.1 to 0.4 MPa
0.1 to 0.6 MPa
MPa
MPa/psi dual scale
Right
Left
Nil
6
Note 1)
Nil
P
Note 2)
Nil
R
Nil
L
Z
Set pressure
range
Mounting
position
Lead wire
length
0.5 m
3 m
5 m
r
Note 1) in the model numbers indicates a thread type. No indication is necessary for
Rc; however, indicate N for NPT, and F for G.
Note 2) Cannot be mounted on the AC40-06-A.
Separate interfaces are required for modular unit.
The pressure switch on the AC40-06-A฀can฀be฀mounted฀by฀screwing฀IS10-01฀into฀the฀
piping฀adapter฀E500-06-A-X501฀(with฀top-face฀thread฀Rc฀1/8).฀Products฀with฀a฀
premounted switch are available as a special order. Please contact SMC regarding
their availability.
Model
Note 1)
IS10E-2001-A
IS10E-2002-A
IS10E-2003-A
IS10E-3002-A
IS10E-3003-A
IS10E-3004-A
IS10E-4002-A
IS10E-4003-A
IS10E-4004-A
IS10E-4006-A
Port size
1/8
1/4
3/8
1/4
3/8
1/2
1/4
3/8
1/2
3/4
Applicable model
Note 2)
AC40-A
A
29.8
31.8
31.8
B
66.3
72.8
78.8
C
55.3
58.8
60.8
D
28
30
37
E
16
13
12.5
AC20-A
AC25-A, AC30-A
Semi-standard
Pressure unit of
the scale plate
AC20-A
AC25-A, AC30-A
AC40-A
AC40-06-A
25
Series AC