Datasheet

Applicable Auto Switches/
Refer to pages 1263 to 1371 in Best Pneumatics No. 2 for further information on auto switches.
Axial piping
CQP2B
CDQP2B
Bore size
12
16
20
25
32
40
50
63
80
100
12 mm
16 mm
20 mm
25 mm
32 mm
40 mm
50 mm
63 mm
80 mm
100 mm
50
50
30
30
M9BW
D
D
Made to Order
Refer to the next page for details.
M9NV
M9PV
M9BV
J79C
M9NWV
M9PWV
M9BWV
M9NAV
∗∗
M9PAV
∗∗
M9BAV
∗∗
M9N
M9P
M9B
M9NW
M9PW
M9BW
M9NA
∗∗
M9PA
∗∗
M9BA
∗∗
F79F
P4DW
A96V
A72
A93V
A90V
A73C
A80C
A79W
A96
A72H
A93
A90
How to Order
Compact Cylinder: Axial Piping
Double Acting, Single Rod
Series CQP2
ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100
With auto switch
(Built-in magnet)
Mounting
B
Through-hole
Cylinder mounting bolts are not included.
Order them separately referring to “Mounting
Bolt for C(D)QP2B” on pages 124 and 127.
Type
Pneumatic
Air-hydro
Note 1)
H
Note 1) Bore sizes available for
air-hydro type are ø20 to ø100.
Built-in Magnet Cylinder Model
If a built-in magnet cylinder without an auto
switch is required, there is no need to enter
the symbol for the auto switch.
(Example) CDQP2B32-30D
M thread
Rc
NPT
G
ø12 to ø25
ø32 to ø100
Port thread type
TN
TF
Number of auto switches
S
n
2 pcs.
1 pc.
“n” pcs.
Auto switch
Without auto switch
Refer to the below table for
applicable auto switches.
Body option
C
M
Standard (Rod end female thread)
With rubber bumper
Note 2)
Rod end male thread
Combination of body option (“CM”) is available.
Note 2) Air-hydro type with rubber bumper is not
available.
Action
D
Double acting
Cylinder stroke (mm)
Refer to the next page for standard strokes.
Type Special function
Electrical
entry
Wiring
(Output)
Load voltage
DC AC
Lead wire length (m)
0.5
(—)
3
(L)
5
(Z)
None
(N)
Applicable load
Pre-wired
connector
1
(M)
Auto switch model
Perpendicular
In-line
Indicator
light
No
Yes
No
Yes
Yes
Grommet
Connector
Grommet
Diagnostic indication
(2-colour indication)
Yes
Connector
Grommet
Grommet
Diagnostic indication
(2-colour indication)
Water resistant
(2-colour indication)
With diagnostic output
(2-colour indication)
Pre-wired
connector
Solid state auto switchReed auto switch
3-wire
(NPN equivalent)
2-wire
3-wire (NPN)
3-wire (PNP)
2-wire
3-wire (NPN)
3-wire (PNP)
2-wire
3-wire (NPN)
3-wire (PNP)
2-wire
4-wire
2-wire (Non-polar)
5 V,
12 V
12 V
5 V,
12 V
12 V
5 V,
12 V
12 V
5 V, 12 V
200 V
100 V
100 V or less
24 V or less
24 V
5 V
12 V
5 V, 12 V
12 V
5 V, 12 V
24 V
IC circuit
IC circuit
IC circuit
IC circuit
Relay,
PLC
IC circuit
IC circuit
IC circuit
Relay,
PLC
Lead wire length symbols: 0.5 m ······· (Example) M9NW
1 m ········· M (Example) M9NWM
3 m ········· L (Example) M9NWL
5 m ········· Z (Example) M9NWZ
None ········ N (Example) J79CN
Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Consult with SMC regarding water resistant types with the above model numbers.
Solid state auto switches marked with “
” are produced upon receipt of order.
The D-P4DWL type is available from ø40 to ø100 only.
Only for the D-P4DWL type, an auto switch is assembled and shipped with the cylinder.
There are other applicable auto switches other than the listed above. For details, refer to page 145.
For details about auto switches with pre-wired connector, refer to pages 1328 and 1329 in Best Pneumatics No. 2.
With auto switch
Without auto switch
Magnetic field resistant
(2-colour indication)
121